EFFECTS OF FUNCTIONAL ELECTRICAL-STIMULATION (FES) ON EVOKED MUSCULAR OUTPUT IN PARAPLEGIC QUADRICEPS MUSCLE

被引:29
|
作者
RABISCHONG, E
OHANNA, F
机构
[1] Inserm U103, Appareil Moteur et Handicap, Montpellier, 34080
[2] Centre Propara, Montpellier, 34080, 263 rue du Caducee, Parc Euromedecine
来源
PARAPLEGIA | 1992年 / 30卷 / 07期
关键词
FUNCTIONAL ELECTRICAL STIMULATION; MUSCLE FATIGUE; MUSCLE TORQUE; PARAPLEGICS; QUADRICEPS MUSCLE;
D O I
10.1038/sc.1992.100
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In order to assess the effects of FES on muscle output, chronic electrical stimulation of the quadriceps muscle was applied for half an hour twice a day for 2 months, in 10 thoracic level traumatic paraplegic patients. Results concerning torque (at 6 different muscle lengths) and fatigue were measured using a strain gauge transducer in isometric condition, and compared with the findings in 15 paraplegic patients who had not received electrical stimulation, and with 10 able bodied subjects with normal motor functions. With training, muscle strength was very significantly improved whilst fatigue resistance remained at a low level. The peak torque was not found to be of the same muscle length when comparing paraplegics and control subjects; it seemed to demonstrate that length-tension relationship of the muscular actuator was changing when it was electrically activated. Moreover, the force recorded in paraplegics remained markedly lower than in able bodied people.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 50 条
  • [1] FUNCTIONAL ELECTRICAL-STIMULATION (FES) OF THE PSOAS MUSCLE IN HEMIPLEGIA
    LLEWELLYN, MGA
    PROCHAZKA, A
    DAVIS, LA
    DOLPHIN, B
    ELEK, JM
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1988, 69 (09): : 730 - 731
  • [2] FUNCTIONAL ELECTRICAL-STIMULATION (FES) - MUSCLE HISTOCHEMICAL ANALYSIS
    GREVE, JMD
    MUSZKAT, R
    SCHMIDT, B
    CHIOVATTO, J
    BARROS, TEP
    BATISTTELLA, LR
    PARAPLEGIA, 1993, 31 (12): : 764 - 770
  • [3] MUSCLE AND BONE IN PARAPLEGIC PATIENTS, AND THE EFFECT OF FUNCTIONAL ELECTRICAL-STIMULATION
    PACY, PJ
    HESP, R
    HALLIDAY, DA
    KATZ, D
    CAMERON, G
    REEVE, J
    CLINICAL SCIENCE, 1988, 75 (05) : 481 - 487
  • [4] EFFECTS OF ELECTRICAL-STIMULATION ON QUADRICEPS MUSCLE MASS AND MORPHOMETRY
    GIBSON, J
    COCHRANE, J
    HUGHES, S
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05): : 851 - 851
  • [5] ELECTRICAL-STIMULATION IN EXERCISE OF THE QUADRICEPS FEMORIS MUSCLE
    CURRIER, DP
    LEHMAN, J
    LIGHTFOOT, P
    PHYSICAL THERAPY, 1979, 59 (12): : 1508 - 1512
  • [6] CONTROL OF KINEMATICS IN PARAPLEGIC GAIT BY FUNCTIONAL ELECTRICAL-STIMULATION
    KOBETIC, R
    MARSOLAIS, EB
    CHIZECK, HJ
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 1579 - 1580
  • [7] THE INFLUENCE OF ORTHOSIS STIFFNESS ON PARAPLEGIC AMBULATION AND ITS IMPLICATIONS FOR FUNCTIONAL ELECTRICAL-STIMULATION (FES) WALKING SYSTEMS
    STALLARD, J
    MAJOR, RE
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1995, 19 (02) : 108 - 114
  • [8] EFFECT OF ANAEROBIC AND AEROBIC EXERCISE PROMOTED BY COMPUTER REGULATED FUNCTIONAL ELECTRICAL-STIMULATION (FES) ON MUSCLE SIZE, STRENGTH AND HISTOLOGY IN PARAPLEGIC MALES
    PACY, PJ
    EVANS, RH
    HALLIDAY, D
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1987, 11 (02) : 75 - 79
  • [9] EFFECTS OF ELECTRICAL-STIMULATION ON MUSCLE PROTEIN-TURNOVER IN PATIENTS WITH QUADRICEPS ATROPHY
    GIBSON, JNA
    MORRISON, WL
    RENNIE, MJ
    SCRIMGEOUR, CM
    SMITH, K
    JOURNAL OF PHYSIOLOGY-LONDON, 1987, 384 : P62 - P62
  • [10] ELECTRICAL-STIMULATION PROVIDING FUNCTIONAL USE OF PARAPLEGIC PATIENT MUSCLES
    KRALJ, A
    BAJD, T
    TURK, R
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1980, 7 (01) : 3 - 9