STEREOTAXIC CORE BIOPSY OF BREAST-LESIONS

被引:124
作者
DRONKERS, DJ
机构
[1] Department of Radiology, Ziekenhuis Velp, 6880 AA Velp
关键词
BIOPSIES; TECHNOLOGY; BREAST; BIOPSY; BREAST NEOPLASMS; DIAGNOSIS; LOCALIZATION;
D O I
10.1148/radiology.183.3.1584909
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 70 selected patients with suspect breast lesions at mammography, accurate, high-speed stereotaxic core-cut biopsy (SCCB) was performed with a biopsy gun. In 17 of the patients, no surgery was performed. The results of SCCB were normal in 11 of these patients; in six patients, the lesion disappeared after SCCB. In 53 of the patients, SCCB was followed by surgical biopsy. In 48 cases (91%), the results of SCCB and surgical biopsy were concordant. Of the 45 carcinomas found at surgery, 41 (91%) were correctly diagnosed with SCCB. There were no false-positive results. SCCB was nondiagnostic (no representative material sampled) in three patients (6%), and in two patients (4%) a false-negative result was obtained. The infiltrating character of the tumor was correctly diagnosed with SCCB in 80% of cases. These results confirm that this radiologic procedure is an acceptable alternative to excisional biopsy.
引用
收藏
页码:631 / 634
页数:4
相关论文
共 11 条
[1]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[2]   NONPALPABLE BREAST-LESIONS - STEREOTAXIC FINE-NEEDLE ASPIRATION CYTOLOGY [J].
CIATTO, S ;
DELTURCO, MR ;
BRAVETTI, P .
RADIOLOGY, 1989, 173 (01) :57-59
[3]   NONPALPABLE BREAST-LESIONS - FINDINGS OF STEREOTAXIC NEEDLE-CORE BIOPSY AND FINE-NEEDLE ASPIRATION CYTOLOGY [J].
DOWLATSHAHI, K ;
YAREMKO, ML ;
KLUSKENS, LF ;
JOKICH, PM .
RADIOLOGY, 1991, 181 (03) :745-750
[4]   STEREOTAXIC NEEDLE LOCALIZATION AND CYTOLOGICAL DIAGNOSIS OF OCCULT BREAST-LESIONS [J].
GENT, HJ ;
SPRENGER, E ;
DOWLATSHAHI, K .
ANNALS OF SURGERY, 1986, 204 (05) :580-584
[5]   RADIOGRAPHICALLY GUIDED FINE-NEEDLE ASPIRATION OF NONPALPABLE BREAST-LESIONS [J].
HELVIE, MA ;
BAKER, DE ;
ADLER, DD ;
ANDERSSON, I ;
NAYLOR, B ;
BUCKWALTER, KA .
RADIOLOGY, 1990, 174 (03) :657-661
[6]   EFFICACY OF AUTOMATED BIOPSY GUNS VERSUS CONVENTIONAL BIOPSY NEEDLES IN THE PYGMY PIG [J].
HOPPER, KD ;
BAIRD, DE ;
REDDY, VV ;
LANDIS, JR ;
PARKER, SH ;
TYLER, HN ;
OWNBEY, JL ;
MCCAUSLIN, MA ;
YAKES, WF ;
SABATELLI, FW ;
MOTT, PL .
RADIOLOGY, 1990, 176 (03) :671-676
[7]  
LOFGREN M, 1988, CANCER, V61, P1032, DOI 10.1002/1097-0142(19880301)61:5<1032::AID-CNCR2820610529>3.0.CO
[8]  
2-R
[9]  
LOVIN JD, 1990, RADIOLOGY, V177, P189
[10]   IMAGE-DIRECTED PERCUTANEOUS BIOPSIES WITH A BIOPSY GUN [J].
PARKER, SH ;
HOPPER, KD ;
YAKES, WF ;
GIBSON, MD ;
OWNBEY, JL ;
CARTER, TE .
RADIOLOGY, 1989, 171 (03) :663-669