TRANSIENTLY EVOKED OTOACOUSTIC EMISSIONS IN DOGS

被引:0
|
作者
SIMS, MH
ROGERS, RK
THELIN, JW
机构
[1] UNIV TENNESSEE,DEPT URBAN PRACTICE,KNOXVILLE,TN 37901
[2] UNIV TENNESSEE,DEPT AUDIOL & SPEECH PATHOL,KNOXVILLE,TN 37901
来源
PROGRESS IN VETERINARY NEUROLOGY | 1994年 / 5卷 / 02期
关键词
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Dogs with normal behavioral responses to sound were lightly anesthetized, and ear canals were examined otoscopically. Tympanograms, acoustic reflexes, and brain stem auditory evoked responses were recorded from test ears to further establish normal auditory function. The dogs were anesthetized with pentobarbital and placed in a sound-attenuating booth in lateral recumbency on a padded surface. Transiently evoked otoacoustic emissions (TEOAE) were recorded unilaterally in response to click stimuli delivered into a closed ear canal at a rate of 50/sec at sound levels of approximately 75 to 95 dB sound pressure level (SPL) in approximately 5-dB steps. Stimulus and recording conditions in the booth remained stable throughout recording sessions. Emissions were recorded from each dog on two separate occasions approximately 1 week apart. Paired TEOAE time-waveforms were analyzed for response amplitude and whole-response reproducibility. Fast Fourier transforms were performed on the time-waveforms, and primary energy peaks were identified in 1-kHz-wide frequency bands. Transiently evoked OAE were successfully recorded from all dogs for most stimuli. Mean (+/- SD) emission amplitudes were 2.9 +/- 4.0, 4.1 +/- 5.2, 8.3 +/- 5.0, 10.5 +/- 4.5, and 14.1 +/- 4.3 dB SPL for stimulus levels of approximately 75, 80, 85, 90, and 95 dB SPL, respectively. Mean whole-response reproducibility ranged from a low of 50% at a stimulus level of 75 dB SPL to a high of 90. 1% at 90 dB SPL. The mean peak energy across stimulus levels ranged from 1.8 to 2.1 kHz, and reproducibility by frequency was consistently the highest at 2 kHz. Analysis of the stimulus revealed a stability that ranged from 94.2 to 97.5% while the noise floor ranged from 32.6 to 33.6 dB SPL. None of the response variables were different (P > 0.05) between recording sessions. Stimulus levels had a significant (P less-than-or-equal-to 0.05) effect on response amplitudes and the number of rejected signals. Stimulus levels that differed by approximately 5 dB SPL did not produce TEOAE with different amplitudes (P > 0.05), whereas response amplitudes differed (P less-than-or-equal-to 0.05) ff evoked by stimulus levels that differed by approximately 10 dB SPL. The TEOAE was shown to be a quick non-invasive method for assessing peripheral auditory function in dogs. Records of evoked emissions add yet another dimension to the clinical assessment of auditory function in dogs. Because TEOAE provide specific information about receptor function, they can be used to distinguish between sensory and neural dysfunction in pathologic conditions resulting in hearing loss.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [31] The feasibility of recording transiently evoked otoacoustic emissions immediately following grommet insertion
    Richardson, HC
    Elliott, C
    Hill, J
    CLINICAL OTOLARYNGOLOGY, 1996, 21 (05): : 445 - 448
  • [32] Suppression effects of transiently evoked otoacoustic emissions in Tae Kwon Do athletes
    Lalaki, P
    Beis, K
    Abatzides, G
    Tsalighopoulos, MG
    Daniilidis, I
    JOURNAL OF HUMAN MOVEMENT STUDIES, 2002, 42 (03): : 185 - 197
  • [33] Transiently evoked otoacoustic emissions as a prognostic indicator in idiopathic sudden hearing loss
    Lalaki, P
    Markou, K
    Tsalighopoulos, MG
    Daniilidis, I
    SCANDINAVIAN AUDIOLOGY, 2001, 30 : 141 - 145
  • [34] TEST RETEST RELIABILITY OF DISTORTION-PRODUCT AND TRANSIENTLY EVOKED OTOACOUSTIC EMISSIONS
    FRANKLIN, DJ
    MCCOY, MJ
    MARTIN, GK
    LONSBURYMARTIN, BL
    EAR AND HEARING, 1992, 13 (06): : 417 - 429
  • [35] Time-frequency analysis of transiently evoked otoacoustic emissions of subjects exposed to noise
    Jedrzejczak, WW
    Blinowska, KJ
    Konopka, W
    HEARING RESEARCH, 2005, 205 (1-2) : 249 - 255
  • [36] THE EFFECTS OF CHRONIC OTITIS-MEDIA WITH EFFUSION ON THE MEASUREMENT OF TRANSIENTLY EVOKED OTOACOUSTIC EMISSIONS
    AMEDEE, RG
    LARYNGOSCOPE, 1995, 105 (06): : 589 - 595
  • [37] Resonant modes in transiently evoked otoacoustic emissions and asymmetries between left and right ear
    Jedrzejczak, W. Wiktor
    Blinowska, Katarzyna J.
    Konopka, Wieslaw
    Journal of the Acoustical Society of America, 2006, 119 (04): : 2226 - 2231
  • [38] Resonant modes in transiently evoked otoacoustic emissions and asymmetries between left and right ear
    Jedrzejczak, WW
    Blinowska, KJ
    Konopka, W
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (04): : 2226 - 2231
  • [39] Influence of eustachian tube dysfunction on transiently evoked and distortion-product otoacoustic emissions
    Schmuziger, N
    Hauser, R
    Probst, R
    HNO, 1996, 44 (06) : 319 - 323
  • [40] Reversible ototoxic effect of azithromycin and clarithromycin on transiently evoked otoacoustic emissions in guinea pigs
    Uzun, C
    Koten, M
    Adali, MK
    Yorulmaz, F
    Yagiz, R
    Karasalihoglu, AR
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2001, 115 (08): : 622 - 628