Test-retest Reliability and Sensitivity to Change of a New Fall Risk Assessment System: A Pilot Study

被引:4
|
作者
Kim, Miji [1 ]
Kim, Sunyoung [2 ]
Won, Chang Won [2 ]
机构
[1] Kyung Hee Univ, East West Med Res Inst, Coll Med, Dept Biomed Sci & Technol, Seoul, South Korea
[2] Kyung Hee Univ, Coll Med, Dept Family Med, Seoul, South Korea
来源
ANNALS OF GERIATRIC MEDICINE AND RESEARCH | 2018年 / 22卷 / 02期
关键词
Fall risk; Balance examination; Reliability; Sensitivity to change; Older adults;
D O I
10.4235/agmr.2018.22.2.80
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: The new fall risk assessment (FRA) system is a composite and comprehensive assessment tool developed to predict the risk of falls. The aim of this pilot study was to examine the new FRA system's test-retest reliability and sensitivity to change in community-dwelling older adults. Methods: This was an observational study with a test-retest design and an 8-week fall prevention exercise program. A sample of 28 community-dwelling older adults with a mean age of 73.0 years (range, 65-80 years) participated in the study. The new FRA system was administered twice within a 7-day period for test-retest reliability expressed as intraclass correlation coefficient (ICC) and standard error of measurement (SEM) assessment. Eighteen subjects of them completed the 8-week fall prevention exercise intervention to evaluate the new FRA system's sensitivity to change. Results: In the evaluation of interrater reliability for the new FRA system, the ICC (95% confidence interval) of the total score was 0.77 (0.47-0.98), with good reliability. The SEM was 11.61 for the total FRA score. A good to excellent reliability was observed, with ICC levels of 0.73 to 0.91 for the 4 composite scores of the new FRA system. Following the 8-week exercise intervention, the mean total FRA score (effect size, 0.58) significantly increased (p=0.028). Conclusion: The new FRA system has generally moderate to excellent interrater reliability and reliable sensitivity to change in community-dwelling older adults. Our findings provide support for the reliability of the new FRA system in healthy older adults without a fall history.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 50 条
  • [21] Test-Retest Reliability of Pain Sensitivity Measures in Individuals with Shoulder Pain
    Othman, Rani
    Bajaber, Abdulrahman Mohammed
    Alhabshi, Anas Mohammed
    Albadi, Majed
    Aldhabi, Rawan
    Almaddah, Muataz
    Alqarni, Abdullah
    JOURNAL OF PAIN RESEARCH, 2024, 17 : 1917 - 1927
  • [22] Test-retest reliability of a new assessment to detect detailed temporal patterns of polysubstance use
    Fitzgerald, Nicole D.
    Liu, Yiyang
    Wang, Anna
    Striley, Catherine W.
    Setlow, Barry
    Knackstedt, Lori
    Cottler, Linda B.
    INTERNATIONAL JOURNAL OF METHODS IN PSYCHIATRIC RESEARCH, 2022, 31 (03)
  • [23] Test-retest reliability of the Chattecx balance system in the patient with hemiplegia
    Levine, D
    Whittle, MW
    Beach, JA
    Ollard, PG
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1996, 33 (01): : 36 - 44
  • [24] Test-retest reliability and practice effects on a shortened version of the Category Switch Task - a pilot study
    Smithies, Tim D.
    Toth, Adam J.
    Campbell, Mark J.
    JOURNAL OF COGNITIVE PSYCHOLOGY, 2024, 36 (06) : 742 - 753
  • [25] The test-retest reliability of a battery of new occupational performance assessments
    Ikiugu, Moses N.
    Anderson, Angela
    Manas, Diane
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2008, 15 (12) : 562 - 570
  • [26] Test-retest reliability of the assessment of motor and process skills in elderly adults
    Doble, SE
    Fisk, JD
    Lewis, N
    Rockwood, K
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1999, 19 (03): : 203 - 215
  • [27] The vestibular evoked myogenic potential: A test-retest reliability study
    Maes, Leen
    Vinck, Bart M.
    De Vel, Eddy
    D'haenens, Wendy
    Bockstael, Annelies
    Keppler, Hannah
    Philips, Birgit
    Swinnen, Freya
    Dhooge, Ingeborg
    CLINICAL NEUROPHYSIOLOGY, 2009, 120 (03) : 594 - 600
  • [28] The Assessment of Reliability Under Range Restriction: A Comparison of α, ω, and Test-Retest Reliability for Dichotomous Data
    Fife, Dustin A.
    Mendoza, Jorge L.
    Terry, Robert
    EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 2012, 72 (05) : 862 - 888
  • [29] GABA, benzodiazepine receptor (GBzR) sensitivity: Test-retest reliability in normal volunteers
    Potokar, J
    Nash, J
    Sandford, J
    Rich, A
    Nutt, D
    HUMAN PSYCHOPHARMACOLOGY-CLINICAL AND EXPERIMENTAL, 2000, 15 (04) : 281 - 286
  • [30] Mobility Assessment under Dual Task Conditions in Women With Fibromyalgia: A Test-Retest Reliability Study
    Murillo-Garcia, Alvaro
    Villafaina, Santos
    Leon-Llamas, Juan Luis
    Sanchez-Gomez, Jesus
    Dominguez-Munoz, Francisco Javier
    Collado-Mateo, Daniel
    Gusi, Narcis
    PM&R, 2021, 13 (01) : 66 - 72