ULTRASOUND VELOCITIES FOR AXIAL EYE LENGTH MEASUREMENT

被引:2
|
作者
HOFFER, KJ
机构
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 1994年 / 20卷 / 05期
关键词
APHAKIA; A-SCAN; AXIAL LENGTH; INTRAOCULAR LENS; POWER CALCULATION; PSEUDOPHAKIA; ULTRASOUND VELOCITY;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Since 1974, I have used individual sound velocities for each eye condition encountered for axial length measurement. The calculation results in 1,555 M/sec for the average phakic eye. A slower speed of 1,549 M/sec was found for an extremely long (30 mm) eye and a higher speed of 1,561 M/sec was noted for an extremely short (20 mm) eye. This inversely proportional velocity change can best be adjusted for by measuring the phakic eye at 1,532 M/sec and correcting the result by dividing the square of the measured axial length (AL1,532)2 by the difference of the measured axial length (AL1,532) minus 0.35 mm. A velocity of 1,534 M/sec was found for all aphakic eyes regardless of their length, and correction is clinically significant. The velocity of an eye containing a poly(methyl methacrylate) intraocular lens is not different from an average phakic eye but it does magnify the effect of axial length change. I recommend measuring the pseudophakic eye at 1,532 M/sec and adding to the result (AL1,532), + 0.04 + 44% of the IOL thickness. The speed for an eye with a silicone IOL was found to be 1,476 M/sec (or AL1,532 + 0.04 - 56% of IOL thickness) and for glass, 1,549 M/sec (or AL1,532 + 0.04 + 75% of IOL thickness). A speed of 1,139 M/sec was found for a phakic eye with silicone oil filling most of the vitreous cavity and 1,052 M/sec for an aphakic eye filled with oil. For varying volumes of oil, each eye should be calculated individually. The speed was 534 M/sec for phakic eyes filled with gas. Eyes containing a silicone IOL or oil or gas will create clinically significant errors (3 to 10 diopters) if the sound velocity is not corrected.
引用
收藏
页码:554 / 562
页数:9
相关论文
共 50 条
  • [1] Transpalpebral measurement of axial eye length
    Martius, P.
    Tech, S.
    Stachs, O.
    Guthoff, R. F.
    OPHTHALMOLOGE, 2010, 107 (08): : 733 - 739
  • [2] Interferometric measurement of the axial length of the eye
    Hård, S
    Fuxin, PO
    Gerhardsson, D
    Torstensson, PA
    Nilsson, T
    Sjöstrand, J
    MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF, 1999, 3564 : 179 - 181
  • [3] Interferometric measurement of the axial length of the eye
    Hard, Sverker
    Fuxin, Per-Ola
    Gerhardsson, Dan
    Torstensson, Per-Arne
    Nilsson, Tomas
    Sjostrand, Johan
    Proceedings of SPIE - The International Society for Optical Engineering, 3564 : 179 - 181
  • [4] ULTRASOUND MEASUREMENT OF OCULAR AXIAL LENGTH
    FLEDELIUS, H
    ACTA OPHTHALMOLOGICA, 1972, 50 (04) : 617 - +
  • [5] THE ACCURACY OF ULTRASONIC MEASUREMENT OF THE AXIAL LENGTH OF THE EYE
    BINKHORST, RD
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (05): : 363 - 365
  • [6] Ultrasound axial length measurement in biphakic eyes
    Hoffer, KJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05): : 961 - 965
  • [7] Measurement of the axial eye length by wavelength tuning interferometry
    Lexer, F
    Hitzenberger, CK
    Kulhavy, M
    Fercher, AF
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 202 - 206
  • [8] Large coherence length swept source for axial length measurement of the eye
    Chong, Changho
    Suzuki, Takuya
    Totsuka, Kohki
    Morosawa, Atsushi
    Sakai, Tooru
    APPLIED OPTICS, 2009, 48 (10) : D144 - D150
  • [9] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [10] REPRODUCIBILITY OF HUMAN EYE LENGTH MEASUREMENT BY ULTRASOUND INVIVO
    POLACH, J
    PREISOVA, J
    BUZEK, J
    ULTRASONICS, 1975, 13 (04) : 185 - 188