WIND-INDUCED VIBRATION OF TOWER AND PRACTICAL APPLICATIONS OF TUNED SLOSHING DAMPER

被引:77
作者
FUJII, K
TAMURA, Y
SATO, T
WAKAHARA, T
机构
[1] TOKYO INST POLYTECH UNIV,DEPT ARCHITECTURE,ATSUGI,KANAGAWA 24302,JAPAN
[2] SHIMIZU CORP,INST TECHNOL,DEPT STRUCT ENGN,TOKYO,JAPAN
[3] SHIMIZU CORP,INST TECHNOL,DEPT UNDERGROUND ENGN,TOKYO,JAPAN
关键词
tuned-sloshing damper; vibration control; Wind-induced vibration;
D O I
10.1016/0167-6105(90)90042-B
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind-induced vibrations of two actual tall towers were reduced to about half upon installation of newly developed Tuned Sloshing Damper, which utilizes liquid motion in circular container. Vibrations at Nagasaki Airport Tower (height 42 m) and Yokohama Marine Tower (height 101 m) were measured during gusty day, before and after installation of damper. The reduced vibration levels after installation were in the range acceptable from the view point of comfort and serviceability. To further estimate the effects of Tuned Sloshing Damper, the dynamic force frequency response function of STD was experimentally determined. Using this frequency response function, numerical simulation on gust responses was conducted. The results indicate that the amplitude level is reduced to about half and this qualitatively agrees well with observation in the Yokohama Marine Tower. © 1990.
引用
收藏
页码:263 / 272
页数:10
相关论文
共 7 条
[1]  
FUJINO Y, 1988, S WORKSHOP SERVICEAB
[2]  
HOUSNER CW, 1957, B SEISMOLOGICAL SOC
[3]  
MCNAMARA RJ, 1985, J STRUCTURAL DIVISIO
[4]  
MODI VJ, 1984, INT C FLOW INDUCED V
[5]  
TAMURA T, 1988, WIND INDUCED VIBRATI, V1
[6]  
1978, RECOMMENDATIONS CALC
[7]  
1975, RULES MINIMUM DESI 2