THE ACCURACY AND PRECISION OF THE ACCUTRACKER AMBULATORY BLOOD-PRESSURE MONITOR

被引:27
作者
APPEL, LJ
WHELTON, PK
SEIDLER, AJ
PATEL, AR
KLAG, MJ
机构
[1] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT MED,BALTIMORE,MD 21205
[2] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT EPIDEMIOL,BALTIMORE,MD 21205
关键词
Blood pressure; Blood pressure determination; Hypertension; Monitoring; physiologic;
D O I
10.1093/oxfordjournals.aje.a115664
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Prerequisite to the use of ambulatory blood pressure monitors in epidemiologic research is demonstration of a satisfactory level of accuracy and precision. Previous evaluations of these devices raise a number of methodological concerns which complicate interpretation of their findings. Also, important issues regarding the precision of blood pressure measurements and the identification of factors associated with measurement inaccuracies remain unaddressed. To assess the accuracy and precision of the Accutracker ambulatory blood pressure monitor, we obtained five serial estimates of resting blood pressure on 120 ambulatory subjects in The Johns Hopkins Medical Institutions in 1987. Two Accutrackers and two manual observers independently recorded blood pressure with the order determined at random. The fourth observer in each sequence obtained a replicate measurement. For both systolic and diastolic blood pressures, the mean difference between Accutracker and manual measurements was less than 3 mmHg for each pairwise comparison. Scatter plots and regression analyses demonstrated that both Accutrackers tended to underestimate high systolic and diastolic blood pressures. In bivariate and murtivariate analyses, increased age was significantly associated with underestimation of systolic blood pressures by both Accutrackers. With respect to the precision of blood pressure measurement, no significant differences were present among the four observers. In summary, our data suggest that the Accutracker has satisfactory accuracy and precision, but that accuracy is not uniform across patient subgroups. © 1990 by The Johns Hopkins University School of Hygiene and Public Health.
引用
收藏
页码:343 / 354
页数:12
相关论文
共 50 条
  • [31] A DISPOSABLE BLOOD-PRESSURE CUFF - AN ASSESSMENT OF ITS ACCURACY
    DODD, FM
    ARMSTRONG, P
    RAY, DC
    SCOTT, DHT
    ANAESTHESIA, 1990, 45 (08) : 666 - 668
  • [32] EFFECT OF EXERCISE TRAINING ON AMBULATORY BLOOD-PRESSURE
    WIJNEN, JAG
    KOOL, MJF
    VANBAAK, MA
    KUIPERS, H
    DEHAAN, CHA
    VERSTAPPEN, FTJ
    BOUDIER, HAJS
    VANBORTEL, LMAB
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1994, 15 (01) : 10 - 15
  • [33] AMBULATORY BLOOD-PRESSURE MONITORING IN HYPERTENSIVE ADOLESCENTS
    FIXLER, DE
    WALLACE, JM
    THORNTON, WE
    DIMMITT, P
    AMERICAN JOURNAL OF HYPERTENSION, 1990, 3 (04) : 288 - 292
  • [34] AMBULATORY BLOOD-PRESSURE MONITORING AND ANTIHYPERTENSIVE TREATMENT
    MANCIA, G
    GIANNATTASIO, C
    OMBONI, S
    EUROPEAN HEART JOURNAL, 1992, 13 : 43 - 47
  • [35] AMBULATORY BLOOD-PRESSURE RECORDINGS IN CHILDREN AND ADOLESCENTS
    HARSHFIELD, GA
    ALPERT, BS
    PULLIAM, DA
    SOMES, GW
    WILSON, DK
    PEDIATRICS, 1994, 94 (02) : 180 - 184
  • [36] AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE SELF-MEASUREMENT IN THE DIAGNOSIS AND MANAGEMENT OF HYPERTENSION
    APPEL, LJ
    STASON, WB
    ANNALS OF INTERNAL MEDICINE, 1993, 118 (11) : 867 - 882
  • [37] SALT RESTRICTION LOWERS RESTING BLOOD-PRESSURE BUT NOT 24-H AMBULATORY BLOOD-PRESSURE
    MOORE, TJ
    MALARICK, C
    OLMEDO, A
    KLEIN, RC
    AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (05) : 410 - 415
  • [38] MICROALBUMINURIA IN ELDERLY HYPERTENSIVES - REPRODUCIBILITY AND RELATION TO CLINIC AND AMBULATORY BLOOD-PRESSURE
    JAMES, MA
    FOTHERBY, MD
    POTTER, JF
    JOURNAL OF HYPERTENSION, 1994, 12 (03) : 309 - 314
  • [39] AMBULATORY LONG-TERM BLOOD-PRESSURE MONITORING - WHAT IS NORMAL
    BAUMGART, P
    ZEITSCHRIFT FUR KARDIOLOGIE, 1991, 80 : 29 - 32
  • [40] AUTOMATED 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING IN PREECLAMPSIA
    MONTAN, S
    CHOOLANI, M
    ARULKUMARAN, S
    RATNAM, SS
    JOURNAL OF PERINATAL MEDICINE, 1995, 23 (05) : 353 - 358