THE ACCURACY AND PRECISION OF THE ACCUTRACKER AMBULATORY BLOOD-PRESSURE MONITOR

被引:28
|
作者
APPEL, LJ
WHELTON, PK
SEIDLER, AJ
PATEL, AR
KLAG, MJ
机构
[1] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT MED,BALTIMORE,MD 21205
[2] JOHNS HOPKINS MED INST,WELCH CTR PREVENT EPIDEMIOL & CLIN RES,DEPT EPIDEMIOL,BALTIMORE,MD 21205
关键词
Blood pressure; Blood pressure determination; Hypertension; Monitoring; physiologic;
D O I
10.1093/oxfordjournals.aje.a115664
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Prerequisite to the use of ambulatory blood pressure monitors in epidemiologic research is demonstration of a satisfactory level of accuracy and precision. Previous evaluations of these devices raise a number of methodological concerns which complicate interpretation of their findings. Also, important issues regarding the precision of blood pressure measurements and the identification of factors associated with measurement inaccuracies remain unaddressed. To assess the accuracy and precision of the Accutracker ambulatory blood pressure monitor, we obtained five serial estimates of resting blood pressure on 120 ambulatory subjects in The Johns Hopkins Medical Institutions in 1987. Two Accutrackers and two manual observers independently recorded blood pressure with the order determined at random. The fourth observer in each sequence obtained a replicate measurement. For both systolic and diastolic blood pressures, the mean difference between Accutracker and manual measurements was less than 3 mmHg for each pairwise comparison. Scatter plots and regression analyses demonstrated that both Accutrackers tended to underestimate high systolic and diastolic blood pressures. In bivariate and murtivariate analyses, increased age was significantly associated with underestimation of systolic blood pressures by both Accutrackers. With respect to the precision of blood pressure measurement, no significant differences were present among the four observers. In summary, our data suggest that the Accutracker has satisfactory accuracy and precision, but that accuracy is not uniform across patient subgroups. © 1990 by The Johns Hopkins University School of Hygiene and Public Health.
引用
收藏
页码:343 / 354
页数:12
相关论文
共 50 条
  • [1] AMBULATORY BLOOD-PRESSURE MONITOR AND ANALYZER
    HILLMAN, D
    OTSUKA, K
    HALBERG, F
    CHRONOBIOLOGIA, 1990, 17 (04) : 305 - 313
  • [2] DISCREPANCIES IN RECORDING SYSTOLIC BLOOD-PRESSURE OF ELDERLY PERSONS BY AMBULATORY BLOOD-PRESSURE MONITOR
    MILLER, ST
    ELAM, JT
    GRANEY, MJ
    APPLEGATE, WB
    AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (01) : 16 - 21
  • [3] COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR
    EPSTEIN, RH
    HUFFNAGLE, S
    BARTKOWSKI, RR
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 161 - 167
  • [4] AMBULATORY BLOOD-PRESSURE MONITORING
    DUGGAN, J
    PHARMACOLOGY & THERAPEUTICS, 1994, 63 (03) : 313 - 321
  • [5] REPEATABILITY OF AUTOMATED AMBULATORY BLOOD-PRESSURE MEASUREMENTS
    PRISANT, LM
    CARR, AA
    BOTTINI, PB
    THOMPSON, WO
    RHOADES, RB
    JOURNAL OF FAMILY PRACTICE, 1992, 34 (05): : 569 - 574
  • [6] AMBULATORY BLOOD-PRESSURE IN PREGNANCY - COMPARISON OF THE SPACELABS-90207 AND ACCUTRACKER-II MONITORS WITH INTRAARTERIAL RECORDINGS
    BROWN, MA
    BUDDLE, ML
    BENNETT, M
    SMITH, B
    MORRIS, R
    WHITWORTH, JA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 173 (01) : 218 - 223
  • [7] EFFECT OF UNRESTRICTED ACTIVITY ON ACCURACY OF AMBULATORY BLOOD-PRESSURE MEASUREMENT
    WEST, JNW
    TOWNEND, JN
    DAVIES, P
    SHERIDAN, JJ
    STALLARD, TJ
    DAVIES, MK
    LITTLER, WA
    HYPERTENSION, 1991, 18 (05) : 593 - 597
  • [8] ACCURACY OF AMBULATORY BLOOD-PRESSURE DETERMINATION - A COMPARATIVE-STUDY
    BARTHELEMY, JC
    GEYSSANT, A
    AUBOYER, C
    ANTONIADIS, A
    BERRUYER, J
    LACOUR, JR
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (05): : 461 - 466
  • [9] ACCURACY OF A CONTINUOUS BLOOD-PRESSURE MONITOR BASED ON ARTERIAL TONOMETRY
    SATO, T
    NISHINAGA, M
    KAWAMOTO, A
    OZAWA, T
    TAKATSUJI, H
    HYPERTENSION, 1993, 21 (06) : 866 - 874
  • [10] AMBULATORY BLOOD-PRESSURE MONITORING IN HYPERTENSION
    MANCIA, G
    ZANCHETTI, A
    CLINICAL AND EXPERIMENTAL HYPERTENSION, 1993, 15 (06) : 1099 - 1108