An Experimental Study on the Thermal Performance Measurement of Vertical Borehole Heat Exchanger(BHE)

被引:6
|
作者
Lim, Kyoungbin
Lee, Changhee
Lee, Sang-Hoon
Soung, Nakwon
机构
关键词
Borehole Heat Exchanger; Thermal Response Test; Thermal Conductivity; Thermal Resistance;
D O I
10.3795/KSME-B.2006.30.8.764
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Knowledge of ground thermal properties is most important for the proper design of large BHE(borehole heat exchanger) systems. Thermal response tests with mobile measurement devices were first introduced in Sweden and USA in 1995. Thermal response tests have so far been used primarily for in insitu determination of design data for BHE systems, but also for evaluation of grout material, heat exchanger types and ground water effects. The main purpose has been to determine insitu values of effective ground thermal conductivity, including the effect of ground-water flow and natural convection in the boreholes. Test rig is set up on a small trailer, and contains a circulation pump, a heater, temperature sensors and a data logger for recording the temperature data. A constant heat power is injected into the borehole through the pipe system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance.
引用
收藏
页码:764 / 771
页数:8
相关论文
共 50 条
  • [1] Analysis of thermal performance and drilling costs of borehole heat exchanger (BHE) in a river deposited area
    Luo, Jin
    Zhang, Yuhao
    Rohn, Joachim
    RENEWABLE ENERGY, 2020, 151 : 392 - 402
  • [2] Thermal performance of a tight borehole heat exchanger
    Dehkordi, S. Emad
    Schincariol, Robert A.
    Reitsma, Stanley
    RENEWABLE ENERGY, 2015, 83 : 698 - 704
  • [3] Long-term performance of BHE (borehole heat exchanger) fields with negligible groundwater movement
    Lazzari, Stefano
    Priarone, Antonella
    Zanchini, Enzo
    ENERGY, 2010, 35 (12) : 4966 - 4974
  • [4] Study on the influence of borehole heat exchanger structure and soil thermal property on soil heat storage characteristics of the HST-BHE system
    Li, Wanfeng
    Hu, Zicheng
    Geng, Shuwen
    Wang, Fengyue
    Liu, Xiaoyuan
    Guo, Yibo
    Huang, Hao
    Han, Yuchen
    APPLIED THERMAL ENGINEERING, 2023, 231
  • [5] Experimental study on geotechnical thermal response test of coaxial borehole heat exchanger
    Guan P.
    Duan X.
    Jiao Y.
    Li P.
    Tan F.
    Zou J.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (02): : 55 - 61
  • [6] A laboratory experimental study of high-temperature thermal storage in the unsaturated soil using a vertical borehole heat exchanger
    Wang, Huajun
    Qi, Chengying
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2011, 6 (03) : 187 - 192
  • [7] Experimental and numerical investigations on the thermal performance of a borehole ground heat exchanger with PCM backfill
    Yang, Weibo
    Xu, Rui
    Yang, Binbin
    Yang, Jingjing
    ENERGY, 2019, 174 : 216 - 235
  • [8] An experimental study on the thermal performance of ground heat exchanger
    Lim, Kyoungbin
    Lee, Sanghoon
    Lee, Changhee
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 31 (08) : 985 - 990
  • [9] Numerical study on the heat performance of enhanced coaxial borehole heat exchanger and double U borehole heat exchanger
    Chen, Ke
    Zheng, Jia
    Li, Juan
    Shao, Jingli
    Zhang, Qiulan
    APPLIED THERMAL ENGINEERING, 2022, 203
  • [10] An improved evaluation method for thermal performance of borehole heat exchanger
    Zhang, Changxing
    Chen, Ping
    Liu, Yufeng
    Sun, Shicai
    Peng, Donggen
    RENEWABLE ENERGY, 2015, 77 : 142 - 151