X-RAY-IMAGING WITH AMORPHOUS SELENIUM - DETECTIVE QUANTUM EFFICIENCY OF PHOTOCONDUCTIVE RECEPTORS FOR DIGITAL MAMMOGRAPHY

被引:56
作者
FAHRIG, R
ROWLANDS, JA
YAFFE, MJ
机构
[1] UNIV TORONTO,DEPT RADIOL,TORONTO,ON M4N 3M5,CANADA
[2] SUNNYBROOK HLTH SCI CTR,TORONTO,ON M4N 3M5,CANADA
关键词
PHOTOCONDUCTOR; DIGITAL MAMMOGRAPHY; DETECTIVE QUANTUM EFFICIENCY; SELENIUM;
D O I
10.1118/1.597599
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Factors affecting the zero spatial frequency detective quantum efficiency of photoconductor-based x-ray detectors operating in the mammographic energy range are modeled for monoenergetic incident x rays. The problem is separated into two sections: the calculation of the x-ray absorption and the Swank factor. X-ray absorption in this energy range, for most practical photoconductors, is dominated by the photoelectric effect. The Swank factor has four components: fluorescence escape, stochastic variations in gain, variations of gain due to incomplete coupling of charge from the photoconductive layer to the detector electrode, and the nonlinear discharge arising from the field-dependent x-ray gain, an effect that is unique to photoconductors. Calculations are performed for selenium, which is currently the most technologically advanced photoconductor available for digital x-ray imaging. For thicknesses of selenium exceeding 50 μm and for energies between 12 and 50 keV, the detective quantum efficiency of this photoconductor is found to exceed that of a conventional Gd2O2S-based mammographic phosphor screen. © 1995, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 27 条
[1]   XERORADIOGRAPHY [J].
BOAG, JW .
PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (01) :3-37
[2]  
BRICH R, 1979, HPA SCI REPORT SERIE, V30, P134
[3]   RADIOGRAPHIC INFORMATION-THEORY AND APPLICATION TO MAMMOGRAPHY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1982, 9 (01) :79-95
[4]   MINIMUM ENTRANCE EXPOSURE ESTIMATES FOR INFORMATION RECORDING IN DIAGNOSTIC-RADIOLOGY [J].
BRODIE, I ;
GUTCHECK, RA .
MEDICAL PHYSICS, 1985, 12 (03) :362-367
[5]   ENERGY AND ANGULAR-DEPENDENCE OF X-RAY ABSORPTION AND ITS EFFECT ON RADIOGRAPHIC RESPONSE IN SCREEN-FILM SYSTEMS [J].
CHAN, HP ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (05) :565-579
[6]   ESCAPE PROBABILITIES FOR FLUORESCENT X-RAYS [J].
DANCE, DR ;
DAY, GJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (03) :259-262
[7]   IMAGE-INFORMATION TRANSFER PROPERTIES OF X-RAY FLUORESCENT SCREENS [J].
DICK, CE ;
MOTZ, JW .
MEDICAL PHYSICS, 1981, 8 (03) :337-346
[8]   OPTICAL FACTORS AFFECTING THE DETECTIVE QUANTUM EFFICIENCY OF RADIOGRAPHIC SCREENS [J].
DRANGOVA, M ;
ROWLANDS, JA .
MEDICAL PHYSICS, 1986, 13 (02) :150-157
[9]  
FIEDLER H, 1981, J INFORM REC MATER, V9, P229
[10]  
GINSBURG A, 1993, MED PHYS, V20, P1013