FOURIER EXTRAPOLATION OF MAGNETIC-FIELDS MEASURED BY ELECTRON-BEAM TOMOGRAPHY

被引:2
作者
SHINADA, H
SUZUKI, Y
机构
[1] Central Research Laboratory, Hitachi, Ltd., Kokubunji
关键词
D O I
10.1063/1.357942
中图分类号
O59 [应用物理学];
学科分类号
摘要
A method for calculating the magnetic field on a plane near a magnetic recording head is presented. In this method, the magnetic field is measured at a plane farther from the head. The method involves taking the Fourier transform of the measured field, enhancing the large wave-number region of the spectrum, and effecting the reverse Fourier transform of the modified spectrum. It is estimated that a field 0.1 μm away from the head can be calculated from a field measured 0.3 μm from it, with a maximum error of less than 0.35%. A field 0.5 μm from a thin-film head calculated from the measured field at 0.7 μm has been compared with actual measurements of the field at 0.5 μm and found to agree within 8%. © 1994 American Institute of Physics.
引用
收藏
页码:7690 / 7694
页数:5
相关论文
共 50 条
  • [31] RESULTS OF A COOPERATIVE TEST FOR THE DETERMINATION OF MAGNETIC STRAY FIELDS IN ELECTRON-BEAM MICROANALYZERS
    PRIES, H
    ARCHIV FUR DAS EISENHUTTENWESEN, 1984, 55 (02): : 81 - 84
  • [32] EVALUATION OF 3-DIMENSIONAL MICROMAGNETIC STRAY FIELDS BY MEANS OF ELECTRON-BEAM TOMOGRAPHY
    ELSBROCK, JB
    SCHROEDER, W
    KUBALEK, E
    IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (05) : 1593 - 1595
  • [33] ELECTRON-BEAM DOSE COMPUTATIONS FOR SHAPED FIELDS
    CHOI, MC
    AGARWAL, SK
    BERK, HW
    BHADURI, D
    MEDICAL PHYSICS, 1984, 11 (03) : 378 - 378
  • [34] Functional imaging with electron-beam computed tomography
    Becker, A
    Becker, C
    Knez, A
    Haberl, R
    Brüning, R
    Reiser, M
    Steinbeck, G
    RADIOLOGE, 1998, 38 (12): : 1021 - 1028
  • [35] ELECTRIC AND MAGNETIC-FIELDS MEASURED DURING A SUDDEN IMPULSE
    SCHUTZ, SR
    ADAMS, GJ
    MOZER, FS
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1973, 54 (11): : 1186 - 1186
  • [36] ELECTRIC AND MAGNETIC-FIELDS MEASURED DURING A SUDDEN IMPULSE
    SCHUTZ, S
    ADAMS, GJ
    MOZER, FS
    JOURNAL OF GEOPHYSICAL RESEARCH, 1974, 79 (13): : 2002 - 2004
  • [37] Application of pharmacokinetics to electron-beam tomography of the abdomen
    Krause, W
    Gröll, R
    Kern, R
    Baumgartner, C
    Rienmüller, R
    ACADEMIC RADIOLOGY, 1999, 6 (08) : 487 - 495
  • [38] Usefulness of electron-beam computed tomography - Discussion
    Crouse, JR
    Raggi, P
    Black, D
    Hecht, H
    Grines, C
    Budoff, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A) : 22B - 23B
  • [39] MAGNETIC COMPRESSION OF A RELATIVISTIC ELECTRON-BEAM
    VLASOV, MA
    KOVALENKO, YA
    MALAFEEV, OA
    NIKONOV, SV
    RADIOTEKHNIKA I ELEKTRONIKA, 1981, 26 (11): : 2370 - 2373
  • [40] ACCUMULATION OF MAGNETIC ENERGY BY AN ELECTRON-BEAM
    LINHART, JG
    KERNTECHNIK, 1987, 50 (03) : 202 - 204