Procedural success and short-and mid-term results of percutaneous closure of persistent arterial duct with the Amplatzer Duct Occluder II

被引:3
作者
Karapinar, Hekim [1 ]
Kucukdurmaz, Zekeriya [1 ]
Sezer, Sadettin [2 ]
Gul, Ibrahim [1 ]
Gumurkcuoglu, Hasan Ali [1 ,4 ]
Kayancicek, Hidayet [4 ]
Asker, Muntecep [4 ]
Baykan, Ali [2 ]
Yilmaz, Ahmet [1 ]
Kaya, Mehmet Gungor [3 ]
Narin, Nazmi [2 ]
机构
[1] Cumhuriyet Univ, Tip Fak, Kardiyol Anabilim Dali, TR-58140 Sivas, Turkey
[2] Erciyes Univ, Tip Fak, Cocuk Kardiyolojisi Bilim Dali, Kayseri, Turkey
[3] Erciyes Univ, Tip Fak, Kardiyol Anabilim Dali, Kayseri, Turkey
[4] Van Yuksek Ihtisas Egitim & Arastirma Hastanesi, Kardiyol Klin, Van, Turkey
来源
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY | 2011年 / 39卷 / 03期
关键词
Child; ductus arteriosus; patent/therapy; equipment design; heart catheterization;
D O I
10.5543/tkda.2011.01396
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We evaluated the effectiveness and reliability of percutaneous closure of persistent arterial duct (PAD) with the Amplatzer Duct Occluder II (ADO II), together with short-and mid-term results. Study design: The study included 16 patients (10 girls, 6 boys; median age 6 years; range 5 months to 12 years) who underwent percutaneous PAD closure with the ADO II device. The ductus diameter was less than 6 mm in all the cases. According to the Krichenko classification, 10 patients had type A, five patients had type E, and one patient had residual PAD. The patients were assessed by aortography and echocardiography. The mean follow-up was 13.9 months (range 2 to 23 months). Results: Closure of PAD was successfully performed via the arterial approach in all the patients. The median ductus waist diameter was 3 mm (range 2 to 5 mm), the median device waist diameter was 4 mm (range 3 to 6 mm), and the waist length was 4 or 6 mm. The mean fluoroscopy time and the mean procedure time were 10.6 min (range 4 to 39 min) and 30 min (range 18 to 80 min), respectively. Immediate aortography following the procedure showed shunt only through the device lumen. No residual shunt or increases in aortic and left pulmonary flow velocities were observed in echocardiographic examinations. No complications occurred during the procedure and follow-up. Conclusion: In all the cases, the ADO II device was found effective and reliable for closure of PADs of less than 6 mm.
引用
收藏
页码:219 / 223
页数:5
相关论文
共 13 条
  • [1] [Anonymous], 2008, AMPL DUCT OCCL 2 PRO
  • [2] The Amplatzer duct occluder: Experience in 209 patients
    Bilkis, AA
    Alwi, M
    Hasri, S
    Haifa, AL
    Geetha, K
    Rehman, MA
    Hasanah, I
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 258 - 261
  • [3] TRANSFEMORAL CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN ADULT PATIENTS
    BONHOEFFER, P
    BORGHI, A
    ONORATO, E
    CARMINATI, M
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1993, 39 (03) : 181 - 186
  • [4] Dua J, 2009, J INVASIVE CARDIOL, V21, P401
  • [5] Early Clinical Experience With the New Amplatzer Ductal Occluder II for Closure of the Persistent Arterial Duct
    Forsey, Jonathan
    Kenny, Damien
    Morgan, Gareth
    Hayes, Alison
    Turner, Mark
    Tometzki, Andrew
    Martin, Robin
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (04) : 615 - 623
  • [6] SURGICAL LIGATION OF A PATENT DUCTUS-ARTERIOSUS - REPORT OF 1ST SUCCESSFUL CASE (REPRINTED)
    GROSS, RE
    HUBBARD, JP
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1984, 251 (09): : 1201 - 1202
  • [7] Huggon IC, 1997, EUR HEART J, V18, P364
  • [8] The snare-assisted technique for transcatheter coil occlusion of moderate to large patent ductus arteriosus: Immediate and intermediate results
    Ing, FF
    Sommer, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) : 1710 - 1718
  • [9] ANGIOGRAPHIC CLASSIFICATION OF THE ISOLATED, PERSISTENTLY PATENT DUCTUS-ARTERIOSUS AND IMPLICATIONS FOR PERCUTANEOUS CATHETER OCCLUSION
    KRICHENKO, A
    BENSON, LN
    BURROWS, P
    MOES, CAF
    MCLAUGHLIN, P
    FREEDOM, RM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) : 877 - 880
  • [10] Catheter closure of moderate- to large-sized patent ductus arteriosus using the new Amplatzer duct occluder: Immediate and short-term results
    Masura, J
    Walsh, KP
    Thanopoulous, B
    Chan, C
    Bass, J
    Goussous, Y
    Gavora, P
    Hijazi, ZM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (04) : 878 - 882