EFFECT OF ELECTRODEPOSITION TEMPERATURE ON CORROSION RESISTANCE OF CALCIUM PHOSPHATE

被引:3
作者
Pastorek, Filip [1 ]
Hadzima, Branislav [1 ,2 ]
Omasta, Miroslav [1 ]
Mhaede, Mansour [3 ,4 ]
机构
[1] Univ Zilina, Fac Mech Engn, Zilina, Slovakia
[2] Univ Zilina, Res Ctr, Zilina, Slovakia
[3] Tech Univ Clausthal, Inst Mat Sci & Engn, D-38678 Clausthal Zellerfeld, Germany
[4] Zagazig Univ, Fac Engn, Ash Sharqiyah, Egypt
来源
ACTA METALLURGICA SLOVACA | 2014年 / 20卷 / 02期
关键词
Calcium phosphate; Magnesium alloy; Electrochemical impedance spectroscopy; Light microscopy; Electrodeposition;
D O I
10.12776/ams.v20i2.290
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Electrodeposition process of calcium phosphate (CaP) was performed at various temperatures on AZ31 magnesium alloy and the influence on corrosion resistance of the alloy covered by CaP was investigated by electrochemical tests supported by photodocumentation. The electrodeposition treatment was performed by potential controlled method in water solution of Ca(NO3)(2).4H(2)O, NH4H2PO4 and H2O2. The difference in the process of CaP formation at various temperatures was described using diagrams of current density time dependence. Corrosion measurements were performed in 0.9% NaCl solution at 22 +/- 2 degrees C using electrochemical impedance spectroscopy. According to corrosion resistance results, the optimal temperature for CaP electrodeposition process was chosen.
引用
收藏
页码:200 / 208
页数:9
相关论文
共 31 条
[1]   Hydroxyapatite-doped poly(lactic acid) porous film coating for enhanced bioactivity and corrosion behavior of AZ31 Mg alloy for orthopedic applications [J].
Abdal-hay, Abdalla ;
Barakat, Nasser A. M. ;
Lim, Jae Kyoo .
CERAMICS INTERNATIONAL, 2013, 39 (01) :183-195
[2]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[3]  
ALBREKTSSON T, 1985, Critical Reviews in Biocompatibility, V1, P53
[4]   Corrosion behaviour of AZ31 magnesium alloy with different grain sizes in simulated biological fluids [J].
Alvarez-Lopez, M. ;
Dolores Pereda, Maria ;
del Valle, J. A. ;
Fernandez-Lorenzo, M. ;
Garcia-Alonso, M. C. ;
Ruano, O. A. ;
Escudero, M. L. .
ACTA BIOMATERIALIA, 2010, 6 (05) :1763-1771
[5]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[6]   Tensile and fatigue behaviour of wrought magnesium alloys AZ31 and AZ61 [J].
Chamos, A. N. ;
Pantelakis, Sp. G. ;
Haidemenopoulos, G. N. ;
Kamoutsi, E. .
FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2008, 31 (09) :812-821
[7]   Fatigue behaviour of bare and pre-corroded magnesium alloy AZ31 [J].
Chamos, A. N. ;
Pantelakis, Sp. G. ;
Spiliadis, V. .
MATERIALS & DESIGN, 2010, 31 (09) :4130-4137
[8]   A simple route towards a hydroxyapatite-Mg(OH)2 conversion coating for magnesium [J].
Chen, X. -B. ;
Birbilis, N. ;
Abbott, T. B. .
CORROSION SCIENCE, 2011, 53 (06) :2263-2268
[9]  
Chen X. B., 2013, ACTABIOMATE IN PRESS, DOI [10.1016/j.actbio.2013.11.016, DOI 10.1016/J.ACTBIO.2013.11.016]
[10]   Biocompatible magnesium alloys as absorbable implant materials - Adjusted surface and subsurface properties by machining processes [J].
Denkena, B. ;
Lucas, A. .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2007, 56 (01) :113-116