Imaging for deep brain stimulation: The zona incerta at 7 Tesla
被引:13
|
作者:
Kerl, Hans U.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Kerl, Hans U.
[1
]
Gerigk, Lars
论文数: 0引用数: 0
h-index: 0
机构:
German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Gerigk, Lars
[2
]
Brockmann, Marc A.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Brockmann, Marc A.
[1
]
Huck, Sonia
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Huck, Sonia
[1
]
Al-Zghloul, Mansour
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Al-Zghloul, Mansour
[1
]
Groden, Christoph
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Groden, Christoph
[1
]
Hauser, Thomas
论文数: 0引用数: 0
h-index: 0
机构:
German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Hauser, Thomas
[2
]
Nagel, Armin M.
论文数: 0引用数: 0
h-index: 0
机构:
German Canc Res Ctr, Dept Med Phys & Radiol, D-69120 Heidelberg, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Nagel, Armin M.
[3
]
Noelte, Ingo S.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, GermanyHeidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
Noelte, Ingo S.
[1
]
机构:
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Neuroradiol, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, Germany
[2] German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Med Phys & Radiol, D-69120 Heidelberg, Germany
来源:
WORLD JOURNAL OF RADIOLOGY
|
2013年
/
5卷
/
01期
关键词:
Deep brain stimulation;
Essential tremor;
Magnetic resonance imaging;
Parkinson's disease;
Zona incerta;
7;
Tesla;
D O I:
10.4329/wjr.v5.i1.5
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
AIM: To evaluate different promising magnetic resonance imaging (MRI) methods at 7.0 Tesla (T) for the pre-stereotactic visualization of the zona incerta (ZI). METHODS: Two neuroradiologists qualitatively and quantitatively examined T2-turbo spin-echo (T2-TSE), T1-weighted gradient-echo, as well as FLASH2D-T2Star and susceptibility-weighted imaging (SWI) for the visualization of the ZI at 7.0 T MRI. Delineation and image quality for the ZI were independently examined using a 6-scale grading system. Inter-rater reliability using Cohen's kappa coefficient (kappa) were assessed. Contrast-tonoise ratios (CNR), and signal-to-noise ratios (SNR) for the ZI were calculated for all sequences. Differences in delineation, SNR, and CNR between the sequences were statistically assessed using a paired t-test. For the anatomic validation the coronal FLASH2D-T2Star images were co-registered with a stereotactic atlas (Schaltenbrand-Wahren). RESULTS: The rostral part of the ZI (rZI) could easily be identified and was best and reliably visualized in the coronal FLASH2D-T2Star images. The caudal part was not definable in any of the sequences. No major artifacts in the rZI were observed in any of the scans. FLASH2D-T2Star and SWI imaging offered significant higher CNR values for the rZI compared to T2-TSE images (P > 0.05). The co-registration of the coronal FLASH2D-T2Star images with the stereotactic atlas schema (Schaltenbrand-Wahren) confirmed the correct localization of the ZI in all cases. CONCLUSION: FLASH2D-T2Star imaging (particularly coronal view) provides the reliable and currently optimal visualization of the rZI at 7.0 T. These results can facilitate a better and more precise targeting of the caudal part of the ZI than ever before. (c) 2013 Baishideng. All rights reserved.
机构:
Heidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany
Kerl, H. U.
Gerigk, L.
论文数: 0引用数: 0
h-index: 0
机构:
German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany
Gerigk, L.
Huck, S.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany
Huck, S.
Al-Zghloul, M.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany
Al-Zghloul, M.
Groden, C.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany
Groden, C.
Noelte, I. S.
论文数: 0引用数: 0
h-index: 0
机构:
Heidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, GermanyHeidelberg Univ, Dept Neuroradiol, Med Fac Mannheim, D-68167 Mannheim, Germany