LIPOPHILIC CROWN-4 DERIVATIVES AS LITHIUM IONOPHORES FOR LITHIUM ION-SELECTIVE LIQUID MEMBRANE ELECTRODES

被引:0
|
作者
KIM, JS [1 ]
JUNG, SO [1 ]
LEE, SS [1 ]
KIM, SJ [1 ]
机构
[1] KOREA UNIV,DEPT CHEM,SEOUL 136701,SOUTH KOREA
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
New lipophilic Crown-4 compounds of 16-membered rings containing furan (neutral carrier, 1), tetrahydrofuran (neutral carrier, II) and lithium complex of the latter (neutral carrier, III) have been synthesized and tested as the active sensors for lithium ion in poly (vinyl chloride) (PVC) membrane electrode, in the presence and absence of an anion excluder, tetrakis (4-chloro-phenyl) borate (KTClPB). 2-nitrophenyl phenyl ether (NPPE), tris (2-ethylhexyl) phosphate (TEHP), o-nitrophenyl octyl ether (NPOE), dioctyl adipate (DOA), bis (2-ethylhexyl) adipate (BEHA), di-n-octyl phenyl phosphonate (DOPP) were used as plasticizing solvent mediators. The electrode response function had a nearly Nernstian slope of 54-61 mV per decade (25-degrees-C ) within the concentration range of 10(-1)-10(-4) M LiCl and the detection limits for all electrodes were ca. 5 X 10(-4) M. The response time of the electrode was faster at the higher lithium concentration and the response of the electrode was stable for longer than 6 months. The sensor membranes exhibit improved response times and increased lifetimes as compared to the system described earlier.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [31] LIPOPHILIC BIS(CROWN ETHER) DERIVATIVES OF 15-CROWN-5 AND 18-CROWN-6 AS NEUTRAL CARRIERS OF ION-SELECTIVE ELECTRODES
    KIMURA, K
    ISHIKAWA, A
    TAMURA, H
    SHONO, T
    JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1984, (03): : 447 - 450
  • [32] PROBLEMS IN THE APPLICATION OF ION-SELECTIVE ELECTRODES TO SERUM LITHIUM ANALYSIS
    GADZEKPO, VPY
    MOODY, GJ
    THOMAS, JDR
    ANALYST, 1986, 111 (05) : 567 - 570
  • [33] SELECTIVITY STUDIES ON LIQUID MEMBRANE, ION-SELECTIVE ELECTRODES
    SRINIVAS.K
    RECHNITZ, GA
    ANALYTICAL CHEMISTRY, 1969, 41 (10) : 1203 - &
  • [34] Double-armed calix[4]arene amide derivatives as ionophores for lead ion-selective electrodes
    Chen, LX
    Zhang, J
    Zhao, WF
    He, XW
    Liu, Y
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 106 - 111
  • [35] LIQUID MEMBRANE ION-SELECTIVE ELECTRODES FOR DIQUAT AND PARAQUAT
    MOODY, GJ
    OWUSU, RK
    THOMAS, JDR
    ANALYST, 1987, 112 (02) : 121 - 127
  • [36] Lead(II)-selective ionophores for ion-selective electrodes: A review
    Guzinski, Marcin
    Lisak, Grzegorz
    Kupis, Justyna
    Jasinski, Artur
    Bochenska, Maria
    ANALYTICA CHIMICA ACTA, 2013, 791 : 1 - 12
  • [37] 1,4,7,10-TETRAOXACYCLODODECANE(12-CROWN-4) AS NEUTRAL CARRIER FOR LITHIUM ION IN LITHIUM ION-SELECTIVE ELECTRODE
    GADZEKPO, VPY
    CHRISTIAN, GD
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1983, 16 (17-1): : 1371 - 1380
  • [38] Salophene metallocomplexes as ionophores in ion-selective electrodes -: an overview
    Wojciechowski, K
    Wróblewski, W
    Przygórzewska, J
    Rokicki, G
    Brzózka, Z
    CHEMIA ANALITYCZNA, 2002, 47 (03): : 335 - 346
  • [39] COMPARATIVE PERFORMANCE OF 14-CROWN-4 DERIVATIVES AS LITHIUM-SELECTIVE ELECTRODES
    KATAKY, R
    NICHOLSON, PE
    PARKER, D
    COVINGTON, AK
    ANALYST, 1991, 116 (02) : 135 - 140
  • [40] SULFONAMIDES AS IONOPHORES FOR ION-SELECTIVE ELECTRODES .1.
    BOCHENSKA, M
    CHOJNACKI, J
    BIERNAT, JF
    JOURNAL OF INCLUSION PHENOMENA, 1987, 5 (06): : 689 - 694