A CHEMICAL CONCENTRATION X-RAY DETERMINATION OF SELENIUM IN COPPER- NICKEL- AND IRON-BASE ALLOYS

被引:9
作者
ALBRIGHT, CH
BURKE, KE
YANAK, MM
机构
[1] International Nickel Company, Inc., Paul D. Merica Research Laboratory, Suffern, NY 10901, Sterling Forest
关键词
D O I
10.1016/0039-9140(69)80017-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the determination of selenium in various metals and alloys at concentrations of 3-100ppm. A chemical separation is made by filtration after reduction of the selenious acid to elemental selenium with hydroxylamine hydrochloride. The pure selenium product is readily analysed by X-ray fluorescence; the method is free from errors due to matrix effects. The relative standard deviation is 6 % for a copper-nickel alloy at the 60 ppm level. © 1969.
引用
收藏
页码:309 / &
相关论文
共 9 条
[1]  
Ariyoshi H., 1960, TALANTA, V5, P112
[2]  
BOCK R, 1964, Z ANAL CHEM, V200, P81
[3]   DETERMINATION OF PARTS-PER-MILLION QUANTITIES OF TELLURIUM IN VARIOUS ALLOYS BY X-RAY SPECTROMETRY [J].
BURKE, KE ;
YANAK, MM ;
ALBRIGHT, CH .
ANALYTICAL CHEMISTRY, 1967, 39 (01) :14-&
[4]  
CHAN FL, 1963, ADV XRAY ANALYSIS, V7, P542
[6]  
HILLEBRAND WF, 1953, APPLIED INORGANIC AN
[7]   DIAMINOBENZIDINE AS A REAGENT FOR VANADIUM AND SELENIUM [J].
HOSTE, J .
ANALYTICA CHIMICA ACTA, 1948, 2 (04) :402-408
[8]  
MICHAELIS RE, 1961, J RES NBS C ENG INST, V65, P71
[9]  
NEWBERRY CL, 1965, J ASSOC OFF AGR CHEM, V48, P322