Visualization of Temperature Distribution around Focal Area and Near Fields of High Intensity Focused Ultrasound Using a 3D Measurement System

被引:2
|
作者
Iwahashi, Toshihide [1 ,4 ]
Tang, Tianhan [1 ]
Matsui, Kazuhiro [1 ]
Fujiwara, Keisuke [2 ]
Itani, Kazunori [2 ]
Yoshinaka, Kiyoshi [3 ]
Azuma, Takashi [1 ]
Takagi, Shu [1 ]
Sakuma, Ichiro [1 ]
机构
[1] Univ Tokyo, Dept Engn, Tokyo, Japan
[2] HITACHI Ltd, Healthcare Business Unit, Tokyo, Japan
[3] Natl Inst Adv Ind Sci & Technol, Hlth Res Inst, Tsukuba, Ibaraki, Japan
[4] Fac Engn, Bunkyo Ku, Room 722,Bldg 14,7-3-1 Hongo, Tokyo 1138656, Japan
来源
ADVANCED BIOMEDICAL ENGINEERING | 2018年 / 7卷
关键词
HIFU; ultrasound; MTLC; visualization; minimally invasive;
D O I
10.14326/abe.7.1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High intensity focused ultrasound (HIFU) is one of the promising minimally invasive therapeutic methods. Focused ultrasound creates coagulation area with minimally invasiveness. Reduction of thermal damage in non-target area during HIFU therapy as well as effective coagulation of the target area are important. In developing a safe and effective HIFU system and control algorithm for HIFU beam manipulation, experimental evaluation of 3D temperature distribution is required to verify the performance of the system under development. In previous studies, several methods for evaluating 3D temperature distribution were introduced, such as MRI thermometry. This method requires consideration of MRI compatibility of the HIFU system. Other methods including thermocouples and thermochromic liquid crystal (TLC) sheet have been used to visualize temperature distribution in experimental acoustic phantoms. However, there were several limitations in evaluating 3D temperature distribution during HIFU exposure. In this study, a 3D temperature distribution measurement system using micro-capsulated thermochromic liquid crystal (MTLC) was developed. We fabricated an optically transparent temperature sensitive phantom containing MTLC that emits a reflectance spectrum depending on temperature. The 3D temperature distribution was visualized using a light sheet method. The temperature distribution in the optical phantom during HIFU exposure was determined with errors as low as 0.6 degrees C. Using this system, temperature distribution induced by HIFU exposure was visualized using different focusing methods to evaluate their performance.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 8 条
  • [1] A portable high-intensity focused ultrasound system for the pancreas with 3D electronic steering: a preclinical study in a swine model
    Chang, Won
    Lee, Jae Young
    Lee, Jae Hwan
    Bae, Jae Seok
    Cho, Yeon Jin
    Kang, Kook Jin
    Son, Keonho
    Chung, Yul Ri
    Lee, Kyoung Bun
    Han, Joon Koo
    ULTRASONOGRAPHY, 2018, 37 (04) : 298 - 306
  • [2] Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm2) intensity focused ultrasound beam using phase shift of ultrasound echoes
    Karwat, Piotr
    Kujawska, Tamara
    Lewin, Peter A.
    Secomski, Wojciech
    Gambin, Barbara
    Litniewski, Jerzy
    ULTRASONICS, 2016, 65 : 211 - 219
  • [3] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Lweesy, Khaldon
    Fraiwan, Luay
    Shatat, Alaa
    Abdo, Ghassan
    Dawodiah, Abduallah
    Sameer, Mohammad
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (03) : 269 - 276
  • [4] Design and ex vivo kidney evaluation of a high-intensity focused ultrasound transducer and 3D positioner
    Khaldon Lweesy
    Luay Fraiwan
    Alaa Shatat
    Ghassan Abdo
    Abduallah Dawodiah
    Mohammad Sameer
    Medical & Biological Engineering & Computing, 2010, 48 : 269 - 276
  • [5] Real-time 3D ultrasound based motion tracking for the treatment of mobile organs with MR-guided high-intensity focused ultrasound
    Bour, Pierre
    Ozenne, Valery
    Marquet, Fabrice
    de Senneville, Baudouin Denis
    Dumont, Erik
    Quesson, Bruno
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2018, 34 (08) : 1225 - 1235
  • [6] Magnetic Resonance-guided High-intensity Focused Ultrasound (MRgHIFU) Virtual Treatment Planning for Abdominal Neuroblastoma Utilizing Retrospective Diagnostic 3D CT Images
    Tung, Stephanie
    Fahy, Aodhnait S.
    Lamberti-Pasculli, Maria
    Waspe, Adam C.
    Pichardo, Samuel
    Gerstle, Justin T.
    JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2019, 41 (07) : E443 - E449
  • [7] Assessment of acute thermal damage volumes in muscle using magnetization-prepared 3D T2-weighted imaging following MRI-guided high-intensity focused ultrasound therapy
    Staruch, Robert M.
    Nofiele, Joris
    Walker, Jamie
    Bing, Chenchen
    Madhuranthakam, Ananth J.
    Bailey, April
    Kim, Young-Sun
    Chhabra, Avneesh
    Burns, Dennis
    Chopra, Rajiv
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (02) : 354 - 364
  • [8] Segmentation of 3-D High-Frequency Ultrasound Images of Human Lymph Nodes Using Graph Cut With Energy Functional Adapted to Local Intensity Distribution
    Kuo, Jen-wei
    Mamou, Jonathan
    Wang, Yao
    Saegusa-Beecroft, Emi
    Machi, Junji
    Feleppa, Ernest J.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (10) : 1514 - 1525