Preoperative measurement of cutaneous melanoma and nevi thickness with photoacoustic imaging

被引:42
作者
Breathnach, Aedan [1 ]
Concannon, Elizabeth [2 ]
Dorairaj, Jemima J. [2 ]
Shaharan, Shazrinizam [2 ]
McGrath, James [1 ]
Jose, Jithin [3 ]
Kelly, Jack L. [2 ]
Leahy, Martin J. [1 ,4 ]
机构
[1] NUI, Tissue Opt & Microcirculat Imaging Facil, Natl Biophoton & Imaging Platform, Galway, Ireland
[2] Univ Hosp Galway, Univ Coll Hosp Galway, Dept Plast & Reconstruct Surg, Galway, Ireland
[3] FUJIFILM Visualson Inc, Amsterdam, Netherlands
[4] Royal Coll Surg RCSI, Natl Biophoton & Imaging Platform, Dublin, Ireland
基金
爱尔兰科学基金会;
关键词
biopsy; Breslow depth; spectral unmixing; histology; staging;
D O I
10.1117/1.JMI.5.1.015004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photoacoustic imaging (PAI) is an emerging biomedical imaging technology, which can potentially be used in the clinic to preoperatively measure melanoma thickness and guide biopsy depth and sample location. We recruited 27 patients with pigmented cutaneous lesions suspicious for melanoma to test the feasibility of a handheld linear-array photoacoustic probe in imaging lesion architecture and measuring tumor depth. The probe was assessed in terms of measurement accuracy, image quality, and ease of application. Photoacoustic scans included single wavelength, spectral unmixing, and three-dimensional (3-D) scans. The photoacoustically measured lesion thickness gave a high correlation with the histological thickness measured from resected surgical samples (r = 0.99, P < 0.001 for melanomas, r = 0.98, P < 0.001 for nevi). Thickness measurements were possible for 23 of 26 cases for nevi and all (6) cases for melanoma. Our results show that handheld, lineararray PAI is highly reliable in measuring cutaneous lesion thickness in vivo, and can potentially be used to inform biopsy procedure and improve patient management. (c) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 34 条
[1]  
American Cancer Society (ACS), 2016, CANC FACTS FIG 2016
[2]  
Belhocine TZ, 2006, J NUCL MED, V47, P957
[3]   Differences between polarized light dermoscopy and immersion contact dermoscopy for the evaluation of skin lesions [J].
Benvenuto-Andrade, Cristiane ;
Dusza, Stephen W. ;
Agero, Anna Liza C. ;
Scope, Alon ;
Rajadhyaksha, Milind ;
Halpern, Allan C. ;
Marghoob, Ashfaq A. .
ARCHIVES OF DERMATOLOGY, 2007, 143 (03) :329-338
[4]   Guidelines of care for the management of primary cutaneous melanoma [J].
Bichakjian, Christopher K. ;
Halpern, Allan C. ;
Johnson, Timothy M. ;
Hood, Antoinette Foote ;
Grichnik, James M. ;
Swetter, Susan M. ;
Tsao, Hensin ;
Barbosa, Victoria Holloway ;
Chuang, Tsu-Yi ;
Duvic, Madeleine ;
Ho, Vincent C. ;
Sober, Arthur J. ;
Beutner, Karl R. ;
Bhushan, Reva ;
Begolka, Wendy Smith .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2011, 65 (05) :1032-1047
[5]   Advances in MR imaging of the skin [J].
Bittoun, Jacques ;
Querleux, Bernard ;
Darrasse, Luc .
NMR IN BIOMEDICINE, 2006, 19 (07) :723-730
[6]   Ultrasonographic staging of cutaneous malignant tumors: an ultrasonographic depth index [J].
Crisan, Maria ;
Crisan, Diana ;
Sannino, Gianpaolo ;
Lupsor, Monica ;
Badea, Radu ;
Amzica, Florin .
ARCHIVES OF DERMATOLOGICAL RESEARCH, 2013, 305 (04) :305-313
[7]   Sensitivity and Specificity of Multiphoton Laser Tomography for In Vivo and Ex Vivo Diagnosis of Malignant Melanoma [J].
Dimitrow, Enrico ;
Ziemer, Mirjana ;
Koehler, Martin Johannes ;
Norgauer, Johannes ;
Koenig, Karsten ;
Elsner, Peter ;
Kaatz, Martin .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2009, 129 (07) :1752-1758
[8]   PREOPERATIVE CHARACTERIZATION OF PIGMENTED SKIN-LESIONS BY EPILUMINESCENCE MICROSCOPY AND HIGH-FREQUENCY ULTRASOUND [J].
DUMMER, W ;
BLAHETA, HJ ;
BASTIAN, BC ;
SCHENK, T ;
BROCHER, EB ;
REMY, W .
ARCHIVES OF DERMATOLOGY, 1995, 131 (03) :279-285
[9]  
Ephrat P., IMAGING MURINE TUMOR
[10]   In vivo photoacoustic microscopy of human cutaneous microvasculature and a nevus [J].
Favazza, Christopher P. ;
Jassim, Omar ;
Cornelius, Lynn A. ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)