EFFECT OF VASCULAR PUNCTURE ON BLOOD-GASES IN THE NEWBORN

被引:6
作者
KIM, EH
COHEN, RS
RAMACHANDRAN, P
机构
[1] Department of Pediatrics, Santa Clara Valley Medical Center, California, 95128., San Jose
关键词
TRANSCUTANEOUS PO2 MONITOR; PULSE OXIMETRY; INDWELLING ARTERIAL PO2 MONITOR; VENIPUNCTURE; INTRAVENOUS CATHETERIZATION;
D O I
10.1002/ppul.1950100411
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Continuous monitoring methods have shown changes of oxygenation in neonates during various procedures. However, actual changes in blood gases during vascular punctures have not been reported. We studied the effect of vascular puncture on arterial blood gases during routine venipuncture in 17 neonates who had indwelling arterial catheters. Arterial blood gases were analyzed before, during, and following recovery from venipuncture. Ventilator settings were not changed during the study, though oxygen concentration (Fi(O2)) was adjusted as indicated by continuous P(O2) or saturation monitors. During venipuncture, there was a significant fall in Pa(CO2) from 38 +/- 5 to 32 +/- 7 mmHg (P < 0.0001) and in Pa(CO2) from 75 +/- 21 to 58 +/- 23 mmHg (P < 0.0001). Following venipuncture, both values returned to baseline. The results of this study imply that blood gases obtained by intermittent arterial sticks may provide data that do not accurately reflect the neonates' respiratory status.
引用
收藏
页码:287 / 290
页数:4
相关论文
共 13 条
[1]  
BANCALARI E, 1986, NEONATAL PULMONARY C
[3]   SKIN SURFACE PCO2 MONITORING IN NEWBORN-INFANTS IN SHOCK - EFFECT OF HYPOTENSION AND ELECTRODE TEMPERATURE [J].
BRUNSTLER, I ;
ENDERS, A ;
VERSMOLD, HT .
JOURNAL OF PEDIATRICS, 1982, 100 (03) :454-457
[4]   CAPILLARY BLOOD-GASES IN THE NEONATE - A REASSESSMENT AND REVIEW OF THE LITERATURE [J].
COURTNEY, SE ;
WEBER, KR ;
BREAKIE, LA ;
MALIN, SW ;
BENDER, CV ;
GUO, S ;
SIERVOGEL, RM .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1990, 144 (02) :168-172
[5]   POTENTIAL ERRORS IN NEONATAL BLOOD-GAS MEASUREMENTS [J].
FAN, LL ;
DELLINGER, KT ;
MILLS, AL ;
HOWARD, RE .
JOURNAL OF PEDIATRICS, 1980, 97 (04) :650-652
[6]  
HICKEY PR, 1985, ANESTH ANALG, V64, P1137
[7]  
JENNIS MS, 1987, PEDIATRICS, V79, P524
[8]   COMPARISON OF PH CARBON DIOXIDE TENSION STANDARD BICARBONATE AND OXYGEN TENSION IN CAPILLARY BLOOD AND IN ARTERIAL BLOOD DURING NEONATAL PERIOD [J].
KOCH, G ;
WENDEL, H .
ACTA PAEDIATRICA SCANDINAVICA, 1967, 56 (01) :10-&
[9]  
PEABODY JL, 1978, AM REV RESPIR DIS, V118, P83
[10]  
PHILLIPS BL, 1988, ASSISTED VENTILATION