CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS

被引:66
|
作者
GUNASINGHAM, H
TAN, CH
机构
[1] Department of Chemistry, National University of Singapore, Kent Ridge
关键词
Amperometric enzyme electrode; Flow injection; Glucose determination; Tetrathiafulvalene; Wall-jet electrode;
D O I
10.1039/an9901500035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a carbon paste - tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing streams is described. The enzyme electrode is operated in a flow-through detector based on the wall-jet configuration under flow injection (FI) and steady-state (SS) conditions. Under FI conditions, high precision (0.6%) and sample throughput (120 samples h-1) are possible. Moreover no pre-conditioning of the electrode is required. The flow system is suitable for the determination of glucose in whole blood without sample dilution. With proper orientation of the jet with respectto the enzyme electrode, high accuracy can be obtained under SS conditions.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
  • [21] Silica sol-gel immobilized amperometric enzyme electrode for peroxide determination in the organic phase
    Li, J
    Tan, SN
    Oh, JT
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1998, 448 (01): : 69 - 77
  • [22] Electrochemical Sensor for the Determination of Paracetamol at Carbamazepine Film Coated Carbon Paste Electrode
    Teradale, Amit B.
    Lamani, Shekappa D.
    Ganesh, Pattan S.
    Swamy, Bahaddurghatta E. Kumara
    Das, Swastika N.
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2018, 232 (03): : 345 - 358
  • [23] Highly sensitive amperometric glucose biosensor based on glassy carbon electrode with copper/palladium coating
    Dai, YQ
    Shiu, KK
    ELECTROANALYSIS, 2004, 16 (21) : 1806 - 1813
  • [24] Amperometric enzyme electrode for free cholesterol determination prepared with cholesterol oxidase immobilized in poly(vinylferrocenium) film
    Ozer, B. Cem
    Ozyoruk, Haluk
    Celebi, Serdar S.
    Yildiz, Atilla
    ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (02) : 262 - 265
  • [25] AMPEROMETRIC ENZYME ELECTRODE FOR NADP(+) BASED ON A FERRODOXIN-NADP(+) REDUCTASE AND VIOLOGEN-MODIFIED GLASSY-CARBON ELECTRODE
    DELACEY, AL
    BES, MT
    GOMEZMORENO, C
    FERNANDEZ, VM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 390 (1-2): : 69 - 76
  • [26] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [27] Amperometric enzyme electrode for organic peroxides determination prepared from horseradish peroxidase immobilized in poly(vinylferrocenium) film
    Gündogan-Paul, M
    Çelebi, SS
    Özyörük, H
    Yildiz, A
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (10) : 875 - 881
  • [28] Batch-Injection Amperometric Determination of Caffeine and Theophylline on an Electrode Modified by Carbon Nanotubes and Ruthenium Oxides
    Shaidarova, L. G.
    Chelnokova, I. A.
    Il'ina, M. A.
    Makhmutova, G. F.
    Akhmatkhanova, F. F.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (08) : 1066 - 1071
  • [29] Flow injection amperometric determination of pyridoxine at a Prussian blue nanoparticle-modified carbon ceramic electrode
    Razmi, H.
    Mohammad-Rezaei, R.
    ELECTROCHIMICA ACTA, 2010, 55 (05) : 1814 - 1819
  • [30] FLOW-INJECTION ANALYSIS OF GLUCOSE AT AN AMPEROMETRIC GLUCOSE SENSOR-BASED ON ELECTROCHEMICAL CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON A GLASSY-CARBON ELECTRODE
    CHI, QJ
    DONG, SJ
    ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 17 - 23