CARBON PASTE-TETRATHIAFULVALENE AMPEROMETRIC ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE IN FLOWING SYSTEMS

被引:66
作者
GUNASINGHAM, H
TAN, CH
机构
[1] Department of Chemistry, National University of Singapore, Kent Ridge
关键词
Amperometric enzyme electrode; Flow injection; Glucose determination; Tetrathiafulvalene; Wall-jet electrode;
D O I
10.1039/an9901500035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a carbon paste - tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing streams is described. The enzyme electrode is operated in a flow-through detector based on the wall-jet configuration under flow injection (FI) and steady-state (SS) conditions. Under FI conditions, high precision (0.6%) and sample throughput (120 samples h-1) are possible. Moreover no pre-conditioning of the electrode is required. The flow system is suitable for the determination of glucose in whole blood without sample dilution. With proper orientation of the jet with respectto the enzyme electrode, high accuracy can be obtained under SS conditions.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 21 条
[1]  
ASTON WJ, 1987, BIOSENSORS FUNDAMENT, P276
[2]   STRATEGIES FOR THE DEVELOPMENT OF AMPEROMETRIC ENZYME ELECTRODES [J].
BARTLETT, PN ;
WHITAKER, RG .
BIOSENSORS, 1988, 3 (06) :359-379
[3]  
CARDOSI M F, 1987, Analytical Proceedings, V24, P143
[4]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[5]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[6]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478
[7]   AMPEROMETRIC ENZYME ELECTRODES [J].
GREEN, MJ ;
HILL, HAO .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1237-1243
[8]   DEVELOPMENT OF AN IN-LINE BLOOD-GLUCOSE MONITOR [J].
GUNASINGHAM, H ;
ANG, KP ;
TEO, PYT ;
TAN, CB ;
TAY, BT ;
AW, TC ;
THAI, AC .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :205-214
[9]   WALL-JET ELECTRODE IN CONTINUOUS MONITORING VOLTAMMETRY [J].
GUNASINGHAM, H ;
FLEET, B .
ANALYTICAL CHEMISTRY, 1983, 55 (08) :1409-1414
[10]  
GUNASINGHAM H, IN PRESS ELECTROANAL