ION-SELECTIVE ELECTRODE POTENTIOMETRIC DETECTION IN ION-CHROMATOGRAPHY

被引:24
|
作者
ISILDAK, I [1 ]
COVINGTON, AK [1 ]
机构
[1] UNIV NEWCASTLE UPON TYNE,DEPT CHEM,ELECTROCHEM RES LABS,NEWCASTLE TYNE NE1 7RU,TYNE & WEAR,ENGLAND
关键词
ION-SELECTIVE ELECTRODES; ION CHROMATOGRAPHY; DETECTION;
D O I
10.1002/elan.1140050916
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anion- and cation-responsive, all solid-state, tubular PVC membrane electrodes were used as detectors in nonsuppressed ion chromatography. Separation and detection of 11 monovalent inorganic and organic anions with a 2 muL cell volume detector were demonstrated using low concentration eluents. A simple and selective method for chromatographic separation and potentiometric detection at sub-ppb levels of seven cations was achieved in 7 minutes. As the detector was selective and sensitive only to monovalent cations, with no interference from other cations, the method was easily applicable to other sample types, including the determination of sodium and potassium ions in inorganic and organic chemicals. The overall efficiency of ion chromatographic procedures allows the possibility of routine separation and detection of inorganic and organic anions and cations at low levels in a simultaneous system. Thus, a simple, selective, sensitive, reproducible method was developed needing only 8 minutes or less to complete an independent separation and simultaneous potentiometric detection of 14 inorganic and organic monovalent common anions and cations with anion and cation-exchange columns in series. The method is flexible as the anions will not interfere with the detection of cations and cations will not interfere with the detection of anions, so that detectors can be used at the end of the two columns in series or one detector can be used at the end of each column. Applications to natural water samples are described.
引用
收藏
页码:815 / 824
页数:10
相关论文
共 50 条
  • [21] Paradox of the Variation of the Bulk Resistance of Potassium Ion-Selective Electrode Membranes within Nernstian Potentiometric Response Range
    Kondratyeva, Ye O.
    Solovyeva, E., V
    Khripoun, G. A.
    Mikhelson, K. N.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (11) : 1118 - 1126
  • [22] Chemical Modification of Polymer Ion-Selective Membrane Electrode Surfaces
    Pawlak, Marcin
    Bakker, Eric
    ELECTROANALYSIS, 2014, 26 (06) : 1121 - 1131
  • [23] Lead ion-selective electrode based on a neutral mobile carrier
    Marin, LP
    Rubi, YM
    de Fuentes, OA
    Ortiz, OF
    Sanchez, EO
    Estevez, OL
    Fajardo, Y
    Chamorro, JA
    Casabo, J
    AFINIDAD, 1998, 55 (474) : 130 - 132
  • [24] WATER HARDNESS ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    HU, ZM
    QI, DY
    ANALYTICA CHIMICA ACTA, 1991, 248 (01) : 177 - 181
  • [25] NITRATE ION-SELECTIVE ELECTRODE AS REFERENCE ELECTRODE FOR FLOW-INJECTION ANALYSIS
    ALONSOCHAMARRO, J
    BARTROLI, J
    JIMENEZ, C
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 419 - 423
  • [26] ION-SELECTIVE ELECTRODE FOR PROCAINAMIDE DETERMINATION IN BLOOD-SERUM
    KATSU, T
    FURUNO, K
    YAMASHITA, S
    GOMITA, Y
    ANALYTICA CHIMICA ACTA, 1995, 312 (01) : 35 - 38
  • [27] Photocured polymers in ion-selective electrode membranes .5. Photopolymerised sodium sensitive ion-selective electrodes for flow injection potentiometry
    Farrell, JR
    Iles, PJ
    Dimitrakopoulos, T
    ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) : 133 - 137
  • [28] ION-SELECTIVE ELECTRODE POTENTIOMETRIC STUDIES ON THE COMPLEXATION OF COPPER(II) BY SOIL-DERIVED HUMIC AND FULVIC-ACIDS
    TOWN, RM
    POWELL, HKJ
    ANALYTICA CHIMICA ACTA, 1993, 279 (02) : 221 - 233
  • [29] POTENTIOMETRIC FLOW-ANALYSIS DEVICE USING MEMBRANE-COATED CARBON ROD ION-SELECTIVE ELECTRODE DETECTORS
    WANG, E
    KAMATA, S
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 399 - 404
  • [30] A chloride ion-selective potentiometric sensor based on a polymeric schiff base complex
    Kumar, KG
    John, KS
    Indira, CJ
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2006, 13 (01) : 13 - 16