AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION

被引:42
|
作者
RISHPON, J
GOTTESFELD, S
CAMPBELL, C
DAVEY, J
ZAWODZINSKI, TA
机构
[1] LOS ALAMOS NATL LAB,LOS ALAMOS,NM 87545
[2] TEL AVIV UNIV,DEPT BIOTECHNOL,IL-69978 RAMAT AVIV,ISRAEL
关键词
BIOSENSOR; GLUCOSE; NAFION;
D O I
10.1002/elan.1140060105
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glucose-sensitive electrode composed of glucose oxidase (GOX) embedded in a layer of the polymer Nafion is described. Electrodes of various configurations on which the layer was cast were tested to determine their response to glucose additions to phosphate buffer and human whole serum samples. These electrodes have good response characteristics and several desirable features. Glucose sensors based on Nafion/GOX layers cast onto platinum electrodes respond to glucose additions with a rapid response time (2 to 4 seconds), have a long lifetime when stored in a phosphate buffer (55 days before termination of testing), have a reduced sensitivity to local oxygen tension, respond linearly to additions of glucose to the serum, and are not fouled by exposure to blood. The Nafion confers some permselectivity on the layer, thus providing a degree of discrimination against anionic interferents.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [1] AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM
    KAKU, T
    KARAN, HI
    OKAMOTO, Y
    ANALYTICAL CHEMISTRY, 1994, 66 (08) : 1231 - 1235
  • [2] AMPEROMETRIC BIOSENSOR FOR GLUCOSE BASED ON NAFION LOADED WITH REDOX COUPLES AND GLUCOSE-OXIDASE
    BELANGER, D
    VAILLANCOURT, M
    FORTIER, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 1 - ANYL
  • [3] GLUCOSE-OXIDASE IMMOBILIZED IN POLYURETHANE MATRIX - A BIOSENSOR FOR AMPEROMETRIC ESTIMATION OF GLUCOSE
    ALVA, S
    PHADKE, RS
    GOVIL, G
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1993, 70 (4-5) : 403 - 408
  • [4] EVALUATION OF NAFION AS MEDIA FOR GLUCOSE-OXIDASE IMMOBILIZATION FOR THE DEVELOPMENT OF AN AMPEROMETRIC GLUCOSE BIOSENSOR
    FORTIER, G
    VAILLANCOURT, M
    BELANGER, D
    ELECTROANALYSIS, 1992, 4 (03) : 275 - 283
  • [5] REVERSIBLY IMMOBILIZED GLUCOSE-OXIDASE IN THE AMPEROMETRIC FLOW-INJECTION DETERMINATION OF GLUCOSE
    DEALWIS, WU
    HILL, BS
    MEIKLEJOHN, BI
    WILSON, GS
    ANALYTICAL CHEMISTRY, 1987, 59 (22) : 2688 - 2691
  • [6] AMPEROMETRIC BIOSENSOR FOR IN-VIVO GLUCOSE SENSING BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN A REDOX HYDROGEL
    LINKE, B
    KERNER, W
    KIWIT, M
    PISHKO, M
    HELLER, A
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (02): : 151 - 158
  • [7] DEVELOPMENT OF A GLUCOSE ANALYZER BASED ON IMMOBILIZED GLUCOSE-OXIDASE
    WATSON, B
    STIFEL, DN
    SEMERSKY, FE
    ANALYTICA CHIMICA ACTA, 1979, 106 (02) : 233 - 242
  • [8] OXIDATION OF GLUCOSE ON IMMOBILIZED GLUCOSE-OXIDASE
    TSUKAMOTO, T
    MORITA, S
    OKADA, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1982, 30 (03) : 782 - 788
  • [9] AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE
    HALE, PD
    LAN, HL
    BOGUSLAVSKY, LI
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) : 121 - 128
  • [10] FERROCENE MODIFIED POLYPYRROLE WITH IMMOBILIZED GLUCOSE-OXIDASE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE MICROBIOSENSORS
    DICKS, JM
    HATTORI, S
    KARUBE, I
    TURNER, APF
    YOKOZAWA, T
    ANNALES DE BIOLOGIE CLINIQUE, 1989, 47 (10) : 607 - 619