SPONTANEOUS BAROREFLEX BY SEQUENCE AND POWER SPECTRAL METHODS IN HUMANS

被引:131
作者
HUGHSON, RL [1 ]
QUINTIN, L [1 ]
ANNAT, G [1 ]
YAMAMOTO, Y [1 ]
GHARIB, C [1 ]
机构
[1] UNIV LYON 1,FAC MED GRANGE BLANCHE,PHYSIOL LAB,F-69365 LYON 2,FRANCE
来源
CLINICAL PHYSIOLOGY | 1993年 / 13卷 / 06期
关键词
BARORECEPTOR; NEGATIVE FEEDBACK; FEED FORWARD; NONINVASIVE BLOOD PRESSURE MONITORING; HEART RATE VARIABILITY; PARASYMPATHETIC NERVOUS SYSTEM; SYMPATHETIC NERVOUS SYSTEM; COLD PRESSOR TEST;
D O I
10.1111/j.1475-097X.1993.tb00481.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Beat-by-beat variations in blood pressure and RR-interval are interrelated by the actions of baroreflex and non-baroreflex responses. This study had two purposes: (1) to examine the spontaneous relationships between RR-interval and systolic blood pressure to determine the relative occurrence of baroreflex and non-baroreflex responses in humans, and (2) to compare the beat-sequence method with a cross spectral estimate of the baroreflex response slope. Eight healthy men were studied during 10 h of quiet, seated rest, and six men and three women were studied during rest, rest plus fixed pace breathing, and a cold pressor test. RR-interval and continuous, non-invasive arterial blood pressure were measured with a computerized system. A baroreflex sequence was defined by a series of at least three consecutive heart beats in which systolic pressure and the following RR-interval either both increased or both decreased. A non-baroreflex relationship was defined by sequences of at least three beats by opposite directional changes of RR-interval and systolic pressure of that beat. The results showed that there were approximately 30% as many non-baroreflex compared to baroreflex slopes. Individual subject mean baroreflex and non-baroreflex slopes were highly correlated (r = 0.72, P < 0.001). Absolute slope values were not different, and they were unaffected by time, fixed pace breathing, or cold pressor test. The data showed the relatively simple beat-by-beat sequence method to yield spontaneous baroreflex response slopes that were quantitatively similar to, and highly correlated with (r = 0.85-0.94), baroreflex response slopes calculated by spectral analysis methods.
引用
收藏
页码:663 / 676
页数:14
相关论文
共 23 条
[1]   EVALUATION OF BARORECEPTOR REFLEX BY BLOOD-PRESSURE MONITORING IN UNANESTHETIZED CATS [J].
BERTINIERI, G ;
DIRIENZO, M ;
CAVALLAZZI, A ;
FERRARI, AU ;
PEDOTTI, A ;
MANCIA, G .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (02) :H377-H383
[2]  
BRISTOW JD, 1971, CIRC RES, V28, P582
[3]   INTERDEPENDENCE OF BLOOD-PRESSURE AND HEART PERIOD REGULATION IN MILD HYPERTENSION [J].
COATS, AJS ;
CONWAY, J ;
SLEIGHT, P ;
MEYER, TE ;
SOMERS, VK ;
FLORAS, JS ;
JONES, JV .
AMERICAN JOURNAL OF HYPERTENSION, 1991, 4 (03) :234-238
[4]  
DEBOER RW, 1987, AM J PHYSIOL, V253, pH680
[5]   THE CHANGES IN THE INTRA-ARTERIAL PRESSURE DURING IMMERSION OF THE HAND IN ICE-COLD WATER [J].
GODDEN, JO ;
ROTH, GM ;
HINES, EA ;
SCHLEGEL, JF .
CIRCULATION, 1955, 12 (06) :963-973
[6]  
HEIDEN UA, 1987, TEMPORAL DISORDER HU
[7]   COMPARISON OF FINAPRES NONINVASIVE BEAT-TO-BEAT FINGER BLOOD-PRESSURE WITH INTRABRACHIAL ARTERY PRESSURE DURING AND AFTER BICYCLE ERGOMETRY [J].
IDEMA, RN ;
VANDENMEIRACKER, AH ;
IMHOLZ, BPM ;
TVELD, AJMI ;
SETTELS, JJ ;
VANECK, HJR ;
SCHALEKAMP, MADH .
JOURNAL OF HYPERTENSION, 1989, 7 :S58-S59
[8]   ARTERIAL BARORECEPTOR REFLEX - ITS CENTRAL AND PERIPHERAL NEURAL MECHANISMS [J].
KUMADA, M ;
TERUI, N ;
KUWAKI, T .
PROGRESS IN NEUROBIOLOGY, 1990, 35 (05) :331-361
[9]  
MANCIA G, 1989, AM J MED, V87, pS64
[10]   CHANGES IN AUTONOMIC REGULATION INDUCED BY PHYSICAL-TRAINING IN MILD HYPERTENSION [J].
PAGANI, M ;
SOMERS, V ;
FURLAN, R ;
DELLORTO, S ;
CONWAY, J ;
BASELLI, G ;
CERUTTI, S ;
SLEIGHT, P ;
MALLIANI, A .
HYPERTENSION, 1988, 12 (06) :600-610