Conventional Humeral Retroversion Measurements Using Computed Tomography Slices or Ultrasound Images Are Not Correlated With the 3-Dimensional Humeral Retroversion Angle

被引:5
|
作者
Saka, Masayuki [1 ]
Yamauchi, Hiroki [1 ]
Yoshioka, Toru [1 ]
Hamada, Hidetoshi [1 ]
Gamada, Kazuyoshi [1 ]
机构
[1] Hamawaki Orthopaed Hosp, Dept Orthopaed Surg, Hiroshima, Japan
关键词
shoulder; general; diagnostic ultrasound; computed tomography; baseball/softball; biomechanics of bone; clinical assessment/grading scales;
D O I
10.1177/2325967115573701
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Humeral retroversion angles determined by previous techniques are varied and/or biased by morphologic variations of the proximal and distal humerus, and their validity should be revisited. To overcome the limitations of previous studies associated with 2-dimensional (2D) images and the reference axes, a 3-dimensional (3D) measurement of humeral retroversion is required. However, comparisons of 2D imaging methods with the 3D computed tomography (CT) measurement as a reference standard have not been heretofore performed. Purpose: To determine whether the 3D CT humeral retroversion angle in baseball players is correlated with conventional humeral retroversion measurements. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: A total of 28 humeri from 14 male baseball players were used for measuring humeral retroversion. Participants underwent CT scans, and geometric bone models were created for measuring the 3D CT humeral retroversion angle. Using CT slices, the 2D CT humeral retroversion angle was also determined. Bicipital forearm angle was assessed using the indirect ultrasound technique. Linear regressions and Bland-Altman plots were used to determine whether there were agreements among 3 variables: the 3D CT retroversion, 2D CT retroversion, and bicipital forearm angles. Results: In linear regression analyses, the 3D humeral retroversion angle was not predicted by the 2D CT retroversion (R = 0.167, R-2 = 0.028, P = .395) or the bicipital forearm angle (R = 0.049, R-2 = 0.002, P = .805). The bias of these 2 methods was 20.9 degrees and -15.3 degrees, respectively. Regression analysis demonstrated that the bicipital forearm angle was a significant predictor of the 2D CT retroversion angle (R = 0.632, R-2 = 0.400, P < .001). Conclusion: The 3D CT humeral retroversion angle was found to be underestimated by the 2D CT retroversion angle and overestimated by the bicipital forearm angle obtained by the indirect ultrasound, although a previously observed relationship between the 2D CT retroversion and bicipital forearm angles was confirmed. Clinical Relevance: Precise measurement of humeral retroversion angle is important because retroversion has been linked to upper extremity disorders, including throwing-related shoulder and elbow disorders in baseball players.
引用
收藏
页数:7
相关论文
共 39 条
  • [31] Anonymization and validation of 3-dimensional volumetric renderings of computed tomography (CT) data using commercially available T1W MRI-based algorithms
    Patel, Rahil
    Provenzano, Destie
    Loew, Murray
    MEDICAL IMAGING 2023, 2023, 12469
  • [32] Simulation study of noise influence in 3-dimensional reconstruction using high-angle hollow-cone dark-field transmission electron microscope images
    Tsuneta, R
    Nakamura, K
    Kakibayashi, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (1A): : 368 - 371
  • [33] 3-dimensional computed tomography lymphography-guided identification of sentinel lymph nodes in breast cancer patients using subcutaneous injection of nonionic contrast medium - A clinical trial
    Minato, M
    Hirose, C
    Sasa, M
    Nishitani, H
    Hirose, Y
    Morimoto, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (01) : 46 - 51
  • [34] Reliability of the modified Walch classification for advanced glenohumeral osteoarthritis using 3-dimensional computed tomography analysis: a study of the ASES B2 Glenoid Multicenter Research Group
    Ricchetti, Eric T.
    Khazzam, Michael S.
    Denard, Patrick J.
    Dines, David M.
    Edwards, T. Bradley
    Entezari, Vahid
    Friedman, Richard J.
    Garrigues, Grant E.
    Gillespie, Robert J.
    Grawe, Brian M.
    Green, Andrew
    Hatzidakis, Armodios M.
    Horneff, J. Gabriel
    Hsu, Jason E.
    Jawa, Andrew
    Jin, Yuxuan
    Johnston, Peter S.
    Jun, Bong-Jae
    Keener, Jay D.
    Kelly, James D., II
    Kwon, Young W.
    Miniaci, Anthony
    Morris, Brent J.
    Namdari, Surena
    Spencer, Edwin E.
    Strnad, Gregory
    Williams, Gerald R., Jr.
    Iannotti, Joseph P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (04) : 736 - 746
  • [35] EVALUATION OF A COMBINED 2-DIMENSIONAL AND 3-DIMENSIONAL COMPRESSION METHOD USING HUMAN VISUAL CHARACTERISTICS TO YIELD HIGH-QUALITY 10/1-COMPRESSION OF CRANIAL COMPUTED-TOMOGRAPHY SCANS
    FRANK, MS
    LEE, HS
    KIM, YM
    ROWBERG, AH
    LEE, WB
    RISKIN, EA
    INVESTIGATIVE RADIOLOGY, 1994, 29 (09) : 842 - 847
  • [36] Quantification of Postoperative Posterior Malleolar Fragment Reduction Using 3-Dimensional Computed Tomography (Q3DCT) Determines Outcome in a Prospective Pilot Study of Patients With Rotational Type Ankle Fractures
    Meijer, Diederik T.
    Keizer, Robert-Jan O. de Muinch
    Stufkens, Joerd A. S.
    Schepers, Tim
    Sierevelt, Inger N.
    Kerkhoffs, Gino M. M. J.
    Goslings, J. Carel
    Doornberg, Job N.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (08) : 404 - 410
  • [37] MULTIMODAL EVALUATION OF 2-D AND 3-D ULTRASOUND, COMPUTED TOMOGRAPHY AND MAGNETIC RESONANCE IMAGING IN MEASUREMENTS OF THE THYROID VOLUME USING UNIVERSALLY APPLICABLE CROSS-SECTIONAL IMAGING SOFTWARE: A PHANTOM STUDY
    Freesmeyer, Martin
    Wiegand, Steffen
    Schierz, Jan-Henning
    Winkens, Thomas
    Licht, Katharina
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (07) : 1453 - 1462
  • [38] Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability
    Lehmkuhl, Lukas H. J.
    von Aspern, Konstantin
    Foldyna, Borek
    Grothoff, Matthias
    Nitzsche, Stefan
    Kempfert, Joerg
    Rastan, Ardawan
    Linke, Axel
    Mohr, Friedrich W.
    Noettling, Alois
    Walther, Thomas
    Gutberlet, Matthias
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (02) : 417 - 424
  • [39] Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability
    Lukas H. J. Lehmkuhl
    Konstantin von Aspern
    Borek Foldyna
    Matthias Grothoff
    Stefan Nitzsche
    Joerg Kempfert
    Ardawan Rastan
    Axel Linke
    Friedrich W. Mohr
    Alois Noettling
    Thomas Walther
    Matthias Gutberlet
    The International Journal of Cardiovascular Imaging, 2013, 29 : 417 - 424