Conventional Humeral Retroversion Measurements Using Computed Tomography Slices or Ultrasound Images Are Not Correlated With the 3-Dimensional Humeral Retroversion Angle

被引:5
|
作者
Saka, Masayuki [1 ]
Yamauchi, Hiroki [1 ]
Yoshioka, Toru [1 ]
Hamada, Hidetoshi [1 ]
Gamada, Kazuyoshi [1 ]
机构
[1] Hamawaki Orthopaed Hosp, Dept Orthopaed Surg, Hiroshima, Japan
关键词
shoulder; general; diagnostic ultrasound; computed tomography; baseball/softball; biomechanics of bone; clinical assessment/grading scales;
D O I
10.1177/2325967115573701
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Humeral retroversion angles determined by previous techniques are varied and/or biased by morphologic variations of the proximal and distal humerus, and their validity should be revisited. To overcome the limitations of previous studies associated with 2-dimensional (2D) images and the reference axes, a 3-dimensional (3D) measurement of humeral retroversion is required. However, comparisons of 2D imaging methods with the 3D computed tomography (CT) measurement as a reference standard have not been heretofore performed. Purpose: To determine whether the 3D CT humeral retroversion angle in baseball players is correlated with conventional humeral retroversion measurements. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: A total of 28 humeri from 14 male baseball players were used for measuring humeral retroversion. Participants underwent CT scans, and geometric bone models were created for measuring the 3D CT humeral retroversion angle. Using CT slices, the 2D CT humeral retroversion angle was also determined. Bicipital forearm angle was assessed using the indirect ultrasound technique. Linear regressions and Bland-Altman plots were used to determine whether there were agreements among 3 variables: the 3D CT retroversion, 2D CT retroversion, and bicipital forearm angles. Results: In linear regression analyses, the 3D humeral retroversion angle was not predicted by the 2D CT retroversion (R = 0.167, R-2 = 0.028, P = .395) or the bicipital forearm angle (R = 0.049, R-2 = 0.002, P = .805). The bias of these 2 methods was 20.9 degrees and -15.3 degrees, respectively. Regression analysis demonstrated that the bicipital forearm angle was a significant predictor of the 2D CT retroversion angle (R = 0.632, R-2 = 0.400, P < .001). Conclusion: The 3D CT humeral retroversion angle was found to be underestimated by the 2D CT retroversion angle and overestimated by the bicipital forearm angle obtained by the indirect ultrasound, although a previously observed relationship between the 2D CT retroversion and bicipital forearm angles was confirmed. Clinical Relevance: Precise measurement of humeral retroversion angle is important because retroversion has been linked to upper extremity disorders, including throwing-related shoulder and elbow disorders in baseball players.
引用
收藏
页数:7
相关论文
共 39 条
  • [1] Reliability of Measuring Humeral Retroversion Using Ultrasound Imaging in a Healthy Nonthrowing Population
    Yoshida, Makoto
    Saho, Yasuaki
    Katayose, Masaki
    JOURNAL OF SPORT REHABILITATION, 2010, 19 (02) : 149 - 160
  • [2] Postoperative assessment of the individualized humeral component retroversion in reverse total shoulder arthroplasty: a novel method applying computed tomography scans without an elbow
    Jeon, Young Dae
    Heo, Kang
    Iran, Luan Khoi
    Yoon, Ji Young
    Jeong, Hyeon Jang
    Oh, Joo Han
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (04) : e187 - e195
  • [3] Correlation of the cross-over ratio of the cross-over sign on conventional pelvic radiographs with computed tomography retroversion measurements
    Werner, Clement M. L.
    Copeland, Carol E.
    Stromberg, Jeff
    Ruckstuhl, Thomas
    SKELETAL RADIOLOGY, 2010, 39 (07) : 655 - 660
  • [4] Correlation of the cross-over ratio of the cross-over sign on conventional pelvic radiographs with computed tomography retroversion measurements
    Clément M. L. Werner
    Carol E. Copeland
    Jeff Stromberg
    Thomas Ruckstuhl
    Skeletal Radiology, 2010, 39 : 655 - 660
  • [5] Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
    Przyklenk, Axel
    Hackl, Michael
    Iuga, Andra-Iza
    Leschinger, Tim
    Maintz, David
    Harbrecht, Andreas
    Mueller, Lars Peter
    Wegmann, Kilian
    SURGICAL AND RADIOLOGIC ANATOMY, 2023, 45 (05) : 571 - 580
  • [6] Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft
    Axel Przyklenk
    Michael Hackl
    Andra-Iza Iuga
    Tim Leschinger
    David Maintz
    Andreas Harbrecht
    Lars Peter Müller
    Kilian Wegmann
    Surgical and Radiologic Anatomy, 2023, 45 : 571 - 580
  • [7] A morphovolumetric study of head malposition in proximal humeral fractures based on 3-dimensional computed tomography scans: the control volume theory
    Russo, Raffaele
    Guastafierro, Antonio
    Pietroluongo, Livia Renata
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (05) : 940 - 949
  • [8] Quantitative 3-Dimensional Computed Tomography Measurements of Coronoid Fractures
    Mellema, Jos J.
    Janssen, Stein J.
    Guitton, Thierry G.
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03): : 526 - 533
  • [9] Reliability and accuracy of the critical shoulder angle measured by anteroposterior radiographs: using digitally reconstructed radiograph from 3-dimensional computed tomography images
    Shibayama, Yuji
    Imamura, Rui
    Hirose, Toshiaki
    Sugi, Akira
    Mizushima, Emi
    Watanabe, Yuto
    Tomii, Rira
    Emori, Makoto
    Teramoto, Atsushi
    Iba, Kousuke
    Yamashita, Toshihiko
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (02) : 286 - 291
  • [10] COMPUTED TOMOGRAPHIC-IMAGES AND 3-DIMENSIONAL EXPRESSION OF CRYSTALLINE LENS FINDINGS FROM MULTIPLE SLICES OF SCHEIMPFLUG SLIT IMAGES
    SAKAMOTO, Y
    SASAKI, K
    OPHTHALMIC RESEARCH, 1995, 27 : 94 - 99