DIRECT DISK DIFFUSION TEST USING EUROPEAN CLINICAL ANTIMICROBIAL SUSCEPTIBILITY TESTING BREAKPOINTS PROVIDES RELIABLE RESULTS COMPARED WITH THE STANDARD METHOD

被引:0
作者
Stokkou, Sofia [1 ]
Geginat, Gernot [1 ]
Schlueter, Dirk [1 ,2 ]
Tammer, Ina [1 ]
机构
[1] Univ Magdeburg, Inst Med Microbiol Infect Control & Prevent, Leipziger Str 44, D-39120 Magdeburg, Germany
[2] Helmholtz Zentrum Infekt Forsch, Braunschweig, Germany
来源
EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY | 2015年 / 5卷 / 01期
关键词
disk diffusion; AST; blood culture; Vitek2; Gram-positive cocci; Gram-negative rods;
D O I
10.1556/EuJMI-D-15-00005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Sepsis represents a life-threatening infection requiring the immediate start of antibacterial treatment to reduce morbidity. Thus, laboratories use direct antimicrobial susceptibility testing (AST) to rapidly generate preliminary results from positive blood cultures. As the direct AST has not yet been published to be evaluated with EUCAST breakpoints, the purpose of the study was to investigate the reliability of the direct agar diffusion test to correctly produce AST results from positive monobacterial blood cultures compared with the VITEK2-based definitive AST, when current EUCAST breakpoints were used. A total of 428 isolates from unselected monobacterial routine blood cultures and 110 challenge strains were included. Direct agar diffusion-based and standard VITEK2-based AST of 2803 bacterium-drug combinations yielded a total clinical category agreement of 95.47% with 1.28% very major errors and 3.42% combined major and minor errors. On the species level, very major errors were observed in the species-drug combinations Enterococcus spp.-high-level gentamicin (10.87%) and Staphylococcus spp.rifampicin (5%), only. No very major errors occurred with Enterobacteriaceae and Pseudomonas aeruginosa. In most species-drug combinations, the direct agar diffusion test using EUCAST breakpoints precisely predicted the result of the definitive antibiotic susceptibility test and, thus, it can be used to optimize empiric antibiotic therapy until definitive results are available.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 29 条
  • [21] Antimicrobial susceptibility testing for Helicobacter pylori isolates from Brazilian children and adolescents: Comparing agar dilution, E-test, and disk diffusion
    Ogata, Silvio Kazuo
    Gales, Ana Cristina
    Kawakami, Elisabete
    [J]. BRAZILIAN JOURNAL OF MICROBIOLOGY, 2014, 45 (04) : 1439 - 1448
  • [22] Comparison of rapid antimicrobial susceptibility testing of flash positive blood culture bottles using disk diffusion and automated broth microdilution on VITEK 2 compact with standard methods: Clinical Laboratory Standards Institute (CLSI) protocol
    Salian, Prerna S.
    Sheth, Dhruti
    Bari, Anurag K.
    Poojary, Aruna
    Rohra, Seema
    Minipriyaa, R.
    [J]. INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2025, 54
  • [23] Antimicrobial susceptibility of Neisseria gonorrhoeae isolates determined by the agar dilution, disk diffusion and Etest methods: comparison of results using GC agar and chocolate agar
    Liao, Chun-Hsing
    Lai, Chih-Cheng
    Hsu, Meng-Shuian
    Chu, Fang-Yeh
    Wu, Mei-Yu
    Huang, Yu-Tsung
    Hsueh, Po-Ren
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2010, 35 (05) : 457 - 460
  • [24] Clinical performance of ASTA SepsiPrep kit in direct bacterial identification and antimicrobial susceptibility test using MicroIDSys Elite and VITEK-2 system
    Yoo, In Young
    Han, Jayho
    Ha, Sung Il
    Cha, Young Jong
    Pil, Shin Dong
    Park, Yeon-Joon
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (06)
  • [25] Development of a EUCAST disk diffusion method for the susceptibility testing of rapidly growing anaerobic bacteria using Fastidious Anaerobe Agar (FAA): a development study using Bacteroides species
    Bavelaar, Herjan
    Justesen, Ulrik Stenz
    Morris, Trefor E.
    Anderson, Bethan
    Copsey-Mawer, Sarah
    Stubhaug, Tore Taksdal
    Kahlmeter, Gunnar
    Matuschek, Erika
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2021, 27 (11) : 1695.e1 - 1695.e6
  • [26] Rapid identification and antimicrobial susceptibility testing of positive blood cultures using MALDI-TOF MS and a modification of the standardised disc diffusion test: a pilot study
    Fitzgerald, C.
    Stapleton, P.
    Phelan, E.
    Mulhare, P.
    Carey, B.
    Hickey, M.
    Lynch, B.
    Doyle, M.
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 2016, 69 (11) : 1025 - 1032
  • [27] Evaluation of a sterile, filter-based, in-house method for rapid direct bacterial identification and antimicrobial susceptibility testing using positive blood culture
    Kim, Keun Ju
    Yun, Seung Gyu
    Cho, Yunjung
    Nam, Myung-Hyun
    Ko, Young Jin
    Lee, Chang Kyu
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2023, 42 (06) : 691 - 700
  • [28] Evaluation of a sterile, filter-based, in-house method for rapid direct bacterial identification and antimicrobial susceptibility testing using positive blood culture
    Keun Ju Kim
    Seung Gyu Yun
    Yunjung Cho
    Myung-Hyun Nam
    Young Jin Ko
    Chang Kyu Lee
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2023, 42 : 691 - 700
  • [29] Direct-from-Blood-Culture Disk Diffusion To Determine Antimicrobial Susceptibility of Gram-Negative Bacteria: Preliminary Report from the Clinical and Laboratory Standards Institute Methods Development and Standardization Working Group
    Chandrasekaran, Sukantha
    Abbott, April
    Campeau, Shelley
    Zimmer, Barbara L.
    Weinstein, Melvin
    Thrupp, Lauri
    Hejna, John
    Walker, Lindsey
    Ammann, Tracy
    Kirn, Thomas
    Patel, Robin
    Humphries, Romney M.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (03)