MERSILENE SUTURES FOR CORNEAL SURGERY

被引:0
作者
FRUCHTPERY, J
机构
来源
OPHTHALMIC SURGERY AND LASERS | 1995年 / 26卷 / 02期
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We studied the complications resulting from using running Mersilene suture in 14 patients who underwent penetrating keratoplasty for keratoconus. 11-0 Mersilene running suture and 12 interrupted 10-0 nylon stitches were used in each procedure and the patients were followed for 22 to 48 months. None of the Mersilene sutures broke, but four were removed in two patients: in one, due to astigmatism or loosening of the suture as a result of sterile ulceration, and in the other, due to herpetic keratitis. Marked scarring manifested along the loops of the sutures in 11 of the Mersilene sutures. Despite these problems, we conclude that the use of Mersilene sutures, alone or combined with nylon sutures, in penetrating keratoplasty is sufficiently advantageous to warrant further study.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 16 条
[1]  
Bertram B A, 1992, Refract Corneal Surg, V8, P296
[2]   ASTIGMATISM AFTER CATARACT-SURGERY - COMPARISON OF WOUND CLOSURE WITH NYLON AND MERSILENE [J].
BIGAR, F .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1990, 196 (05) :314-315
[3]   THE UNRESOLVED PROBLEM OF HIGH POSTKERATOPLASTY ASTIGMATISM [J].
BIGAR, F ;
UFFER, S .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1992, 200 (05) :401-403
[4]   THE EFFECT OF SUTURE REMOVAL ON POSTKERATOPLASTY ASTIGMATISM [J].
BINDER, PS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (06) :637-645
[5]   AN ADJUSTABLE DOUBLE RUNNING SUTURE TECHNIQUE FOR KERATOPLASTY [J].
CLINCH, TE ;
THOMPSON, HW ;
GARDNER, BP ;
KAUFMAN, SC ;
KAUFMAN, HE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 116 (02) :201-206
[7]  
DREWS RC, 1989, OPHTHALMIC SURG LAS, V20, P695
[8]  
FRUCHTPERY J, 1993, OPHTHALMIC SURG LAS, V24, P516
[9]   RUNNING NYLON SUTURE DISSOLUTION AFTER PENETRATING KERATOPLASTY [J].
FRUEH, BE ;
FELDMAN, ST ;
FELDMAN, RM ;
SOSSI, NP ;
FRUCHTPERY, J ;
BROWN, SI .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :406-411
[10]   11-0 MERSILENE AS RUNNING SUTURE FOR PENETRATING KERATOPLASTY [J].
FRUEH, BE ;
BROWN, SI ;
FELDMAN, ST .