Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010

被引:13
|
作者
Bramlage, Peter [1 ]
Deutsch, Cornelia [1 ]
Krueger, Ralf [1 ]
Wolf, Andreas [2 ]
Mueller, Peter [2 ]
Zwingers, Thomas [1 ,4 ]
Beime, Beate [1 ]
Mengden, Thomas [3 ]
机构
[1] Inst Pharmakol & Pravent Med, Bahnhofstrasse 20, D-49661 Cloppenburg, Germany
[2] Muller & Sebastiani, Ottobrunn, Germany
[3] Kerckhoff Klin, Bad Nauheim, Germany
[4] Estimate, Augsburg, Germany
关键词
validation; ambulatory blood pressure monitoring; ESH;
D O I
10.2147/VHRM.S63602
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Materials and methods: Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. Results: The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was -0.5 +/- 4.5 mmHg for SBP and -0.1 +/- 3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. Conclusion: The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [21] Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Bilo, Grzegorz
    Zorzi, Cristina
    Munera, Juan E. Ochoa
    Torlasco, Camilla
    Giuli, Valentina
    Parati, Gianfranco
    BLOOD PRESSURE MONITORING, 2015, 20 (05) : 291 - 294
  • [22] Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010
    Benetti, Elisabetta
    Fania, Claudio
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 50 - 53
  • [23] Validation of the AGILIS ambulatory blood pressure monitor according to the European Society of Hypertension International protocol for validation of blood pressure measuring devices in adults
    Mallion, JJM
    Pierre, H
    Neuder, Y
    Ormezzano, O
    Baguet, JP
    BLOOD PRESSURE MONITORING, 2005, 10 (02) : 97 - 101
  • [24] Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Zeng, Wei-Fang
    Liu, Ming
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 46 - 49
  • [25] Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Chen, Qi
    Kang, Yuan-Yuan
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (02) : 105 - 108
  • [26] Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Chen, Qi
    Liu, Chang-Yuan
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 45 - 48
  • [27] Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Huang, Jinhua
    Li, Zhijie
    Li, Guimei
    Liu, Zhaoying
    BLOOD PRESSURE MONITORING, 2015, 20 (05) : 283 - 285
  • [28] Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Lei, Lei
    Chen, Yi
    Chen, Qi
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (06) : 371 - 374
  • [29] Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Zhang, Lu
    Kang, Yuan-Yuan
    Zeng, Wei-Fang
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2015, 20 (02) : 104 - 107
  • [30] Validation of the Beneware model ABP-021 ambulatory blood pressure monitor according to the revised 2010 European Society of hypertension international protocol
    Pereira, Telmo
    Guimaraes, Joao
    BLOOD PRESSURE MONITORING, 2018, 23 (04) : 210 - 213