MORE RELIABLE PCR FOR DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN CLINICAL-SAMPLES

被引:184
作者
KOX, LFF
RHIENTHONG, D
MIRANDA, AM
UDOMSANTISUK, N
ELLIS, K
VANLEEUWEN, J
VANHEUSDEN, S
KUIJPER, S
KOLK, AHJ
机构
[1] ACAD MED CENTRUM AMSTERDAM,DIV PULM DIS,AMSTERDAM,NETHERLANDS
[2] CHULALONGKORN UNIV,FAC MED,DEPT MICROBIOL,BANGKOK 10330,THAILAND
[3] TB DIV,BANGKOK,THAILAND
[4] INST NACL SAUDE,OPORTO,PORTUGAL
关键词
D O I
10.1128/JCM.32.3.672-678.1994
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Diagnostic techniques based on PCR have two major problems: false-positive reactions due to contamination with DNA fragments from previous PCRs (amplicons) and false-negative reactions caused by inhibitors that interfere with the PCR. We have improved our previously reported PCR based on the amplification of a fragment of the Mycobacterium tuberculosis complex-specific insertion element IS6110 with respect to both problems. False-positive reactions caused bg amplicon contamination were prevented by the use of uracil-N-glycosylase and dUTP instead of dTTP. We selected a new set of primers outside the region spanned by the formerly used primers to avoid false-positive reactions caused by dTTP-containing amplicons still present in the laboratory. With this new primer set, 16 copies of the IS6110 insertion element, the equivalent of two bacteria, could be amplified 10(10) times in 40 cycles, resulting in a mean efficiency of 77% per cycle. To detect the presence of inhibitors of the Tag polymerase, which may cause false-negative reactions, part of each sample was spiked with M. tuberculosis DNA. The DNA purification method using guanidinium thiocyanate and diatoms effectively removed most or ah inhibitors of the PCR. However, this was not suitable for blood samples, for which we developed a proteinase K treatment followed by phenol-chloroform extraction. This method permitted detection of 20 M. tuberculosis bacteria per mi of whale blood. Various laboratory procedures were introduced to reduce failure or inhibition of PCR and avoid DNA cross contamination. We have tested 218 different clinical specimens obtained from patients suspected of having tuberculosis. The samples included sputum (Ir = 145), tissue biopsy samples (n = 25), cerebrospinal fluid (n = 15), blood (n = 14), pleural fluid (n = 9), feces (n = 7), fluid from fistulae (n = 2), and pus from a wound (n = I). The results obtained by PCR were consistent with those obtained with culture, which is the ''gold standard.'' We demonstrate that PCR is a useful technique for the rapid diagnosis of tuberculosis at various sites.
引用
收藏
页码:672 / 678
页数:7
相关论文
共 25 条
  • [1] RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS
    BOOM, R
    SOL, CJA
    SALIMANS, MMM
    JANSEN, CL
    WERTHEIMVANDILLEN, PME
    VANDERNOORDAA, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) : 495 - 503
  • [2] DIAGNOSIS OF TUBERCULOSIS BY DNA AMPLIFICATION IN CLINICAL-PRACTICE EVALUATION
    BRISSONNOEL, A
    AZNAR, C
    CHUREAU, C
    NGUYEN, S
    PIERRE, C
    BARTOLI, M
    BONETE, R
    PIALOUX, G
    GICQUEL, B
    GARRIGUE, G
    [J]. LANCET, 1991, 338 (8763) : 364 - 366
  • [3] BRISSONNOEL A, 1989, LANCET, V2, P1069
  • [4] USE OF POLYMERASE CHAIN-REACTION FOR RAPID DIAGNOSIS OF TUBERCULOSIS
    COUSINS, DV
    WILTON, SD
    FRANCIS, BR
    GOW, BL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (01) : 255 - 258
  • [5] DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN SPUTUM SAMPLES USING A POLYMERASE CHAIN-REACTION
    EISENACH, KD
    SIFFORD, MD
    CAVE, MD
    BATES, JH
    CRAWFORD, JT
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (05): : 1160 - 1163
  • [6] Groothuis D. G., 1991, DIAGNOSTIC PUBLIC HL
  • [7] SPECIFIC DETECTION OF MYCOBACTERIUM-TUBERCULOSIS COMPLEX STRAINS BY POLYMERASE CHAIN-REACTION
    HERMANS, PWM
    SCHUITEMA, ARJ
    VANSOOLINGEN, D
    VERSTYNEN, CPHJ
    BIK, EM
    THOLE, JER
    KOLK, AHJ
    VANEMBDEN, JDA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (06) : 1204 - 1213
  • [8] DETECTION OF MYCOBACTERIUM-TUBERCULOSIS IN CLINICAL-SAMPLES BY USING POLYMERASE CHAIN-REACTION AND A NONRADIOACTIVE DETECTION SYSTEM
    KOLK, AHJ
    SCHUITEMA, ARJ
    KUIJPER, S
    VANLEEUWEN, J
    HERMANS, PWM
    VANEMBDEN, JDA
    HARTSKEERL, RA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (10) : 2567 - 2575
  • [9] KUBICA GP, 1963, AM REV RESPIR DIS, V87, P775
  • [10] USE OF URACIL DNA GLYCOSYLASE TO CONTROL CARRY-OVER CONTAMINATION IN POLYMERASE CHAIN-REACTIONS
    LONGO, MC
    BERNINGER, MS
    HARTLEY, JL
    [J]. GENE, 1990, 93 (01) : 125 - 128