SPONTANEOUS INJECTION IN MICROCOLUMN SEPARATIONS

被引:57
作者
FISHMAN, HA [1 ]
AMUDI, NM [1 ]
LEE, TT [1 ]
SCHELLER, RH [1 ]
ZARE, RN [1 ]
机构
[1] STANFORD UNIV,DEPT CHEM,STANFORD,CA 94305
关键词
D O I
10.1021/ac00086a018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The phenomenon of spontaneous (ubiquitous) injection in microcolumn separations has been characterized to improve quantitative precision for ultramicrosampling and to enhance separation efficiency. By combining fluorescence imaging, video microscopy, and measurements from capillary electrophoresis, we demonstrate that spontaneous injection is caused primarily by an interfacial pressure difference formed at the inlet of the capillary. This complex injection mechanism has been modeled with some simple assumptions based on fluid dynamics. In particular, studies showed that extraneous injection is reduced up to 12-fold by etching the capillary inlet or by using a thin-walled capillary. Variations by a factor of 2 in the injection length can result from delays between sample introduction and reinsertion into the inlet vial if the timing is not controlled precisely. Evidence is presented that evaporation of buffer from the inlet can reduce the injection length by more than 1 order of magnitude.
引用
收藏
页码:2318 / 2329
页数:12
相关论文
共 49 条
[21]   DETERMINATION OF INTRACELLULAR SPECIES AT THE LEVEL OF A SINGLE ERYTHROCYTE VIA CAPILLARY ELECTROPHORESIS WITH DIRECT AND INDIRECT FLUORESCENCE DETECTION [J].
HOGAN, BL ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2841-2845
[22]   EVALUATION OF AN AUTOMATIC SIPHONIC SAMPLER FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HONDA, S ;
IWASE, S ;
FUJIWARA, S .
JOURNAL OF CHROMATOGRAPHY, 1987, 404 (02) :313-320
[23]   ANALYSIS OF FACTORS CAUSING PEAK BROADENING IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
COLEMAN, WF ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :95-110
[24]  
HUNTER RJ, 1987, F COLLOID SCI, V1, P272
[25]   MICROCOLUMN SEPARATIONS AND THE ANALYSIS OF SINGLE CELLS [J].
KENNEDY, RT ;
OATES, MD ;
COOPER, BR ;
NICKERSON, B ;
JORGENSON, JW .
SCIENCE, 1989, 246 (4926) :57-63
[26]   PNEUMATIC MICROSYRINGE FOR USE AS AN INJECTOR IN OPEN TUBULAR LIQUID-CHROMATOGRAPHY AND AS A DISPENSER IN MICROANALYSIS [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (15) :1521-1524
[27]   IMAGING OF ELECTROPHORETIC FLOW ACROSS A CAPILLARY JUNCTION [J].
KUHR, WG ;
LICKLIDER, L ;
AMANKWA, L .
ANALYTICAL CHEMISTRY, 1993, 65 (03) :277-282
[28]  
LAPLACE PSD, 1829, SUPPLEMENT 10TH LIVR
[29]   QUANTITATIVE-DETERMINATION OF NATIVE PROTEINS IN INDIVIDUAL HUMAN ERYTHROCYTES BY CAPILLARY ZONE ELECTROPHORESIS WITH LASER-INDUCED FLUORESCENCE DETECTION [J].
LEE, TT ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :3045-3051
[30]   USE OF AN ON-COLUMN FRACTURE IN CAPILLARY ZONE ELECTROPHORESIS FOR SAMPLE INTRODUCTION [J].
LINHARES, MC ;
KISSINGER, PT .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2076-2078