CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES

被引:92
|
作者
GRAF, T
FISCHER, H
REUL, H
RAU, G
机构
关键词
MECHANICAL HEART VALVES; CAVITATION THRESHOLD; MATERIAL EROSION; BLOOD DAMAGE;
D O I
10.1177/039139889101400309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Just like technical check valves, the function of mechanical heart valve prostheses may presumably also lead to cavitation effects during valve closure. Due to the waterhammer effect, cavitation may primarily occur in the mitral position leading to high mechanical loading of the valve itself and of corpuscular blood elements. Ten different types of commercial mechanical heart valves were investigated in the mitral position of a pulsatile mock loop, to detect cavitation thresholds under physiologically similar conditions by cinematographic techniques. Almost all these valve prostheses show cavitation up to a ventricular pressure gradient of 5000 mmHg/s. The threshold depends on valve type and size and is sometimes within the physiological range below 2000 mmHg/s. Visible cavitation bubbles with a diameter of up to 1.8 mm and a collapse time of less than 0.1 ms suggest that vapour cavitation may play an important role for material and blood damage in mechanical heart valve prostheses.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [1] INVITRO PULSATILE FLOW HEMODYNAMICS OF 5 MECHANICAL AORTIC HEART-VALVE PROSTHESES
    WALKER, PG
    YOGANATHAN, AP
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 : S113 - S123
  • [2] Mechanical heart valve cavitation
    Johansen, P
    EXPERT REVIEW OF MEDICAL DEVICES, 2004, 1 (01) : 95 - 104
  • [3] Anticoagulation in pregnant women with mechanical heart valve prostheses: Case reports and a literature review
    Adebola, Philip Alaba
    Daniel, Folasade A.
    Oshodi, Yusuf A.
    Gbadegesin, Abidoye
    Ale, Olagoke K.
    Oluwole, Ayodeji O.
    Falase, Olabode
    Oludara, Mobolaji A.
    Nwiloh, Jonathan
    NIGERIAN POSTGRADUATE MEDICAL JOURNAL, 2021, 28 (01) : 68 - 70
  • [4] Inhibition of blood coagulation activation and oral anticoagulants in patients with mechanical heart valve prostheses
    Barcellona, D
    Mameli, G
    Marongiu, F
    THROMBOSIS RESEARCH, 1996, 81 (03) : 403 - 406
  • [5] Value of molecular markers in the initial phase of oral anticoagulation therapy after heart valve replacement with mechanical prostheses
    Dahm, M
    Lotz, J
    Hafner, G
    Oelert, H
    Prellwitz, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 : 42 - 45
  • [6] Challenges in managing anticoagulant therapy in patients with heart valve prostheses
    Vink, Roel
    Kamphuisen, Pieter-Willem
    van den Brink, Renee B.
    Levi, Marcel
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2007, 5 (03) : 563 - 570
  • [7] Developments in mechanical heart valve prosthesis
    Kalyani Nair
    C. V. Muraleedharan
    G. S. Bhuvaneshwar
    Sadhana, 2003, 28 : 575 - 587
  • [8] On the Closing Sounds of a Mechanical Heart Valve
    Changfu Wu
    Bruce A. Herman
    Stephen M. Retta
    Laurence W. Grossman
    Jia-Shing Liu
    Ned H. C. Hwang
    Annals of Biomedical Engineering, 2005, 33 : 743 - 750
  • [9] On the closing sounds of a mechanical heart valve
    Wu, CF
    Herman, BA
    Retta, SM
    Grossman, LW
    Liu, JS
    Hwang, NHC
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (06) : 743 - 750
  • [10] The Apex bileaflet mechanical heart valve
    Mohammadi H.
    Bhullar A.
    Journal of Medical Engineering and Technology, 2021, 45 (01) : 41 - 51