CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES

被引:92
|
作者
GRAF, T
FISCHER, H
REUL, H
RAU, G
机构
来源
关键词
MECHANICAL HEART VALVES; CAVITATION THRESHOLD; MATERIAL EROSION; BLOOD DAMAGE;
D O I
10.1177/039139889101400309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Just like technical check valves, the function of mechanical heart valve prostheses may presumably also lead to cavitation effects during valve closure. Due to the waterhammer effect, cavitation may primarily occur in the mitral position leading to high mechanical loading of the valve itself and of corpuscular blood elements. Ten different types of commercial mechanical heart valves were investigated in the mitral position of a pulsatile mock loop, to detect cavitation thresholds under physiologically similar conditions by cinematographic techniques. Almost all these valve prostheses show cavitation up to a ventricular pressure gradient of 5000 mmHg/s. The threshold depends on valve type and size and is sometimes within the physiological range below 2000 mmHg/s. Visible cavitation bubbles with a diameter of up to 1.8 mm and a collapse time of less than 0.1 ms suggest that vapour cavitation may play an important role for material and blood damage in mechanical heart valve prostheses.
引用
收藏
页码:169 / 174
页数:6
相关论文
共 50 条
  • [1] CAVITATION DYNAMICS OF MECHANICAL HEART-VALVE PROSTHESES
    LEE, CS
    CHANDRAN, KB
    CHEN, LD
    ARTIFICIAL ORGANS, 1994, 18 (10) : 758 - 767
  • [2] HEART-VALVE PROSTHESES AND EXTERNAL MECHANICAL VIBRATIONS
    LAMBERTZ, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1990, 115 (07) : 274 - 275
  • [3] CURRENT HEART-VALVE PROSTHESES
    LEFRAK, EA
    STARR, A
    AMERICAN FAMILY PHYSICIAN, 1979, 20 (03) : 93 - 99
  • [4] Cavitation caused by mechanical heart valve prostheses - A review
    Johansen, P
    Travis, BR
    Paulsen, PK
    Nygaard, H
    Hasenkam, JM
    APMIS, 2003, 111 : 108 - 112
  • [5] THROMBOEMBOLIC AND BLEEDING COMPLICATIONS IN PATIENTS WITH MECHANICAL HEART-VALVE PROSTHESES
    CANNEGIETER, SC
    ROSENDAAL, FR
    BRIET, E
    CIRCULATION, 1994, 89 (02) : 635 - 641
  • [6] MECHANICAL HEART-VALVE PROSTHESES - SOUND LEVEL AND RELATED COMPLAINTS
    LAURENS, RRP
    WIT, HP
    EBELS, T
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (02) : 57 - 61
  • [7] INVITRO HEMOLYSIS BY MECHANICAL HEART-VALVE PROSTHESES WITH TILTING DISK
    WENDT, MO
    POHL, M
    PRATSCH, S
    LERCHE, D
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (11): : 681 - 685
  • [8] ALLOPLASTIC MATERIALS FOR HEART-VALVE PROSTHESES
    BAURSCHMIDT, P
    SCHALDACH, M
    BIOMEDIZINISCHE TECHNIK, 1980, 25 (04): : 89 - 95
  • [9] A RANDOMIZED TRIAL OF HEART-VALVE PROSTHESES
    BLOOMFIELD, P
    KITCHIN, AH
    LUTZ, W
    WALBAUM, PR
    WHEATLEY, DJ
    MILLER, HC
    CIRCULATION, 1985, 72 (04) : 209 - 209
  • [10] A RANDOMIZED TRIAL OF HEART-VALVE PROSTHESES
    BLOOMFIELD, P
    KITCHIN, AH
    LUTZ, W
    WALBAUM, PR
    WHEATLEY, DJ
    MILLER, HC
    BRITISH HEART JOURNAL, 1985, 53 (06): : 668 - 669