POLY(XYLYLVIOLOGEN) ELECTRON-TRANSFER MEDIATORS IN AMPEROMETRIC GLUCOSE SENSORS

被引:9
|
作者
HALE, PD
BOGUSLAVSKY, LI
SKOTHEIM, TA
KARAN, HI
LAN, HL
OKAMOTO, Y
机构
[1] CUNY MEDGAR EVERS COLL,DIV NAT SCI & MATH,BROOKLYN,NY 11225
[2] POLYTECH INST NEW YORK,DEPT CHEM,BROOKLYN,NY 11201
来源
关键词
D O I
10.1080/00268949008047849
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
引用
收藏
页码:259 / 264
页数:6
相关论文
共 50 条
  • [1] INVESTIGATION OF VIOLOGEN DERIVATIVES AS ELECTRON-TRANSFER MEDIATORS IN AMPEROMETRIC GLUCOSE SENSORS
    HALE, PD
    BOGUSLAVSKY, LI
    KARAN, HI
    LAN, HL
    LEE, HS
    OKAMOTO, Y
    SKOTHEIM, TA
    ANALYTICA CHIMICA ACTA, 1991, 248 (01) : 155 - 161
  • [2] POLY(ETHER AMINE QUINONE)S AS ELECTRON-TRANSFER RELAY SYSTEMS IN AMPEROMETRIC GLUCOSE SENSORS
    LAN, HL
    KAKU, T
    KARAN, HI
    OKAMOTO, Y
    DIAGNOSTIC BIOSENSOR POLYMERS, 1994, 556 : 124 - 136
  • [3] AMPEROMETRIC GLYCOLATE SENSORS BASED ON GLYCOLATE OXIDASE AND POLYMERIC ELECTRON-TRANSFER MEDIATORS
    HALE, PD
    INAGAKI, T
    LEE, HS
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 31 - 37
  • [4] QUINONE POLYMERS AS ELECTRON-TRANSFER RELAY SYSTEMS IN AMPEROMETRIC GLUCOSE SENSORS
    OKAMOTO, Y
    LAN, HL
    KAFU, T
    KAREN, H
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 55 - IEC
  • [5] VIOLOGEN DERIVATIVE CONTAINING POLYSILOXANE AS AN ELECTRON-TRANSFER MEDIATOR IN AMPEROMETRIC GLUCOSE SENSORS
    KARAN, HI
    LAN, HL
    OKAMOTO, Y
    DIAGNOSTIC BIOSENSOR POLYMERS, 1994, 556 : 169 - 179
  • [6] Dipolar ruthenium(II) ammine complexes as electron transfer mediators of amperometric glucose sensors
    Nakabayashi, Yasuo
    Hirosaki, Yuri
    Yamauchi, Osamu
    BIOELECTROCHEMISTRY, 2006, 69 (02) : 216 - 222
  • [7] Evaluation of osmium(II) complexes as electron transfer mediators accessible for amperometric glucose sensors
    Nakabayashi, Y
    Omayu, A
    Yagi, S
    Nakamura, K
    ANALYTICAL SCIENCES, 2001, 17 (08) : 945 - 950
  • [8] Evaluation of Osmium(II) Complexes as Electron Transfer Mediators Accessible for Amperometric Glucose Sensors
    Yasuo Nakabayashi
    Atsushi Omayu
    Shiro Yagi
    Kazuyo Nakamura
    Junko Motonaka
    Analytical Sciences, 2001, 17 : 945 - 950
  • [9] VIOLOGEN-DERIVATIVE-CONTAINING POLYSILOXANE AS ELECTRON-TRANSFER MEDIATOR IN AMPEROMETRIC GLUCOSE SENSORS
    LAN, HL
    OKAMOTO, Y
    SKOTHEIM, TA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 59 - IEC
  • [10] AMPEROMETRIC GLUCOSE SENSOR WITH TETRATHIAFULVALENE AS AN ELECTRON-TRANSFER MEDIATOR
    SUN, CQ
    YANG, X
    LUAN, CX
    GAO, Q
    XU, HD
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 1995, 11 (03): : 189 - 194