OPTIMIZATION OF DIFFUSE REFLECTANCE INFRARED-SPECTROSCOPY ACCESSORIES

被引:11
|
作者
HIRSCHFELD, T
机构
[1] Lawrence Livermore Natl Lab,, Livermore, CA, USA, Lawrence Livermore Natl Lab, Livermore, CA, USA
关键词
MIRRORS; -; Applications;
D O I
10.1366/0003702864507729
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The value of diffuse reflectance as an infrared or near-infrared spectroscopic sampling procedure has been limited by the low efficiency of accessories designed for it. In terms of signal-to-noise ratio, these average 2-6% for integrating spheres and 10-12% for various ellipsoidal mirror arrangements. Much better performances, up to 37% efficiency, can be obtained by optimizing a concentric confocal ellipsoidal mirror arrangement by using a very large central opening in the amular collector mirror, and adapting the throughput of the detector to the geometry of the collected beam.
引用
收藏
页码:1082 / 1085
页数:4
相关论文
共 50 条
  • [1] OPTIMIZATION OF SAMPLE PACKING IN DIFFUSE-REFLECTANCE INFRARED-SPECTROSCOPY
    KRIVACSY, Z
    HLAVAY, J
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1994, 50 (01): : 49 - 55
  • [2] DIFFUSE-REFLECTANCE INFRARED-SPECTROSCOPY
    RAYMOND, KW
    CORKILL, JA
    JOURNAL OF CHEMICAL EDUCATION, 1994, 71 (08) : A204 - A204
  • [3] DIFFUSE REFLECTANCE INFRARED-SPECTROSCOPY STUDIES OF THE OXIDATION OF COAL SURFACES
    FULLER, EL
    SMYRL, NR
    BRITTON, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 55 - FUEL
  • [4] QUANTITATIVE DIFFUSE REFLECTANCE AND TRANSMITTANCE INFRARED-SPECTROSCOPY OF NONDILUTED POWDERS
    BOROUMAND, F
    MOSER, JE
    VANDENBERGH, H
    APPLIED SPECTROSCOPY, 1992, 46 (12) : 1874 - 1886
  • [5] DIFFUSE REFLECTANCE INFRARED-SPECTROSCOPY OF ADSORBATES ON SUPPORTED METAL-CATALYSTS
    HOLMES, PD
    MCDOUGALL, GS
    WILCOCK, IC
    WAUGH, KC
    CATALYSIS TODAY, 1991, 9 (1-2) : 15 - 22
  • [6] QUANTIFICATION OF SILICA IN MINE DUSTS USING DIFFUSE REFLECTANCE INFRARED-SPECTROSCOPY
    BABU, VS
    SEEHRA, MS
    APPLIED SPECTROSCOPY, 1993, 47 (06) : 830 - 833
  • [7] A SIMPLE DEVICE FOR DIFFUSE REFLECTANCE FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    MAULHARDT, H
    KUNATH, D
    APPLIED SPECTROSCOPY, 1980, 34 (03) : 383 - 385
  • [8] STUDIES OF MOLECULAR-SIEVE CATALYSIS BY DIFFUSE REFLECTANCE INFRARED-SPECTROSCOPY
    MARONI, VA
    MARTIN, KA
    JOHNSON, SA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 75 - IEC
  • [9] COMPARISON OF CALIBRATION METHODS IN QUANTITATIVE DIFFUSE-REFLECTANCE INFRARED-SPECTROSCOPY
    KRIVACSY, Z
    HLAVAY, J
    TALANTA, 1995, 42 (04) : 613 - 620
  • [10] SAMPLE ROTATION IN DIFFUSE REFLECTANCE FOURIER-TRANSFORM INFRARED-SPECTROSCOPY
    VELAPOLDI, RA
    TVEDT, JE
    CHRISTY, AA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (06): : 1126 - 1128