MR-IMAGING OF THE LIVER - BREATH-HOLD T1-WEIGHTED MP-GRE COMPARED WITH CONVENTIONAL T2-WEIGHTED SE IMAGING - LESION DETECTION, LOCALIZATION, AND CHARACTERIZATION

被引:29
作者
DELANGE, EE [1 ]
MUGLER, JP [1 ]
BOSWORTH, JE [1 ]
DEANGELIS, GA [1 ]
GAY, SB [1 ]
HURT, NS [1 ]
BERR, SS [1 ]
ROSENBLATT, JM [1 ]
MERICKEL, LW [1 ]
HARRIS, EK [1 ]
机构
[1] UNIV VIRGINIA,HLTH SCI CTR,DIV BIOSTAT,CHARLOTTESVILLE,VA 22908
关键词
LIVER; MR; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; RAPID IMAGING; TECHNOLOGY; TISSUE CHARACTERIZATION;
D O I
10.1148/radiology.190.3.8115619
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare breath-hold T1-weighted magnetization-prep ared gradient-echo (MP-GRE) imaging with conventional T2-weighted spin-echo (SE) imaging in evaluation of focal liver disease. MATERIALS AND METHODS: Images of 68 patients evaluated for focal liver disease were reviewed. Five sets of images were analyzed: axial, sagittal, and coronal breath-hold T1-weighted MP-GRE images, axial T2-weighted SE images, and a compilation of axial, sagittal, and coronal (three-plane) T1-weighted ME-GEE images. Lesion signal intensity (SI) and signal difference-to-noise (SD/N) ratios were calculated. RESULTS: Lesions were detected, localized, and characterized more accurately (P <.05-.001) and with greater confidence on three-plane T1-weighted ME-GEE images than on almost all single-plane images. Mean SI ratios of nonsolid and solid lesions on MP-GRE and SE images were significantly different at all lesion sizes; mean SD/N ratio was significantly different only for large lesions. CONCLUSION: Lesion detection, localization, and characterization can be accurately and confidently performed with three-plane T1-weighted MP-GRE breath-hold imaging, potentially obviating conventional T2-weighted SE imaging.
引用
收藏
页码:727 / 736
页数:10
相关论文
共 46 条
[1]   AREA ABOVE ORDINAL DOMINANCE GRAPH AND AREA BELOW RECEIVER OPERATING CHARACTERISTIC GRAPH [J].
BAMBER, D .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1975, 12 (04) :387-415
[2]  
BOTTOMLEY PA, 1986, BOOK ABSTRACTS SOC M, P407
[3]   FOCAL HEPATIC-LESIONS - DIFFERENTIATION WITH MR-IMAGING AT 0.5 T [J].
BROWN, JJ ;
LEE, JM ;
LEE, JKT ;
VANLOM, KJ ;
MALCHOW, SC .
RADIOLOGY, 1991, 179 (03) :675-679
[4]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[5]   SMALL HEPATOCELLULAR-CARCINOMA VERSUS SMALL CAVERNOUS HEMANGIOMA - DIFFERENTIATION WITH MR IMAGING AT 2.0 T [J].
CHOI, BI ;
HAN, MC ;
KIM, CW .
RADIOLOGY, 1990, 176 (01) :103-106
[6]   SOME METHODS FOR STRENGTHENING THE COMMON X2 TESTS [J].
COCHRAN, WG .
BIOMETRICS, 1954, 10 (04) :417-451
[7]  
COUINEAUD C, 1990, CHIRURGIE, V106, P8
[8]   MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
GAY, SB ;
JANUS, CL ;
BROOKEMAN, JR .
MAGNETIC RESONANCE IMAGING, 1991, 9 (04) :469-476
[9]   SELECTIVE VERSUS NONSELECTIVE PREPARATION PULSES IN 2-DIMENSIONAL MP-RAGE IMAGING OF THE LIVER [J].
DELANGE, EE ;
MUGLER, JP ;
BERTOLINA, JA ;
BROOKEMAN, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :355-358
[10]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845