USEFULNESS OF THE BLOOD PATCH TECHNIQUE AFTER TRANSTHORACIC NEEDLE ASPIRATION BIOPSY

被引:45
作者
HERMAN, SJ
WEISBROD, GL
机构
[1] Department of Radiology, Toronto General Hospital, Toronto, Ont.
关键词
D O I
10.1148/radiology.176.2.2367653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors investigated the effectiveness of the blood patch technique in reducing the pneumothorax and chest tube insertion rates after transthoracic needle lung biopsy. Biopsy of 100 pulmonary nodules was performed with a coaxial system. In this prospective, randomized study, patients either received a blood patch (group A, n = 46) or did not (group B, n = 47). Seven procedures were excluded: five for technical reasons and two because of lack of follow-up information. Comparison of the two groups by means of χ2 analysis and the Student t test revealed no difference in the mean age, gender, smoking history, proportion of heavy smokers, nodule size, presence of cavitation, or number of needle passes. The pneumothorax rate was 24% (11 of 46 patients) in group A and 30% (14 of 47 patients) in group B. The chest tube insertion rate was 2.2% (one patient) in group A and 2.1% (one patient) in group B. The difference between the groups in either rate was not significant (P > .5). The blood patch technique did not lower the rate of pneumothorax or chest tube insertion.
引用
收藏
页码:395 / 397
页数:3
相关论文
共 16 条
  • [1] BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
  • [2] TRANS-THORACIC NEEDLE ASPIRATION BIOPSY - EVALUATION OF THE BLOOD PATCH TECHNIQUE
    BOURGOUIN, PM
    SHEPARD, JAO
    MCLOUD, TC
    SPIZARNY, DL
    DEDRICK, CG
    [J]. RADIOLOGY, 1988, 166 (01) : 93 - 95
  • [3] POSTBIOPSY PNEUMOTHORAX - ESTIMATING THE RISK BY CHEST RADIOGRAPHY AND PULMONARY-FUNCTION TESTS
    FISH, GD
    STANLEY, JH
    MILLER, KS
    SCHABEL, SI
    SUTHERLAND, SE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (01) : 71 - 74
  • [4] GREENE RE, 1982, INTERVENTIONAL RADIO, P587
  • [5] USEFULNESS OF NEEDLE-BIOPSY IN CHEST LESIONS OF DIFFERENT SIZES AND LOCATIONS
    JEREB, M
    [J]. RADIOLOGY, 1980, 134 (01) : 13 - 15
  • [6] MCCARTNEY T, 1974, AM J ROENTGENOL, V120, P872
  • [7] PERCUTANEOUS TRANS-THORACIC NEEDLE ASPIRATION - A REVIEW
    PERLMUTT, LM
    JOHNSTON, WW
    DUNNICK, NR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) : 451 - 455
  • [8] PERLMUTT LM, 1986, AM J ROENTGENOL, V146, P1049, DOI 10.2214/ajr.146.5.1049
  • [9] PREDICTING RISK OF PNEUMOTHORAX IN NEEDLE-BIOPSY OF THE LUNG
    POE, RH
    KALLAY, MC
    WICKS, CM
    ODOROFF, CL
    [J]. CHEST, 1984, 85 (02) : 232 - 235
  • [10] QUON D, 1988, J CAN ASSOC RADIOL, V39, P267