SIMULTANEOUS QUANTIFICATION OF CYCLOSPORINE-A AND ITS MAJOR METABOLITES BY TIME-OF-FLIGHT SECONDARY-ION MASS-SPECTROMETRY AND MATRIX-ASSISTED LASER DESORPTION/IONIZATION MASS-SPECTROMETRY UTILIZING DATA-ANALYSIS TECHNIQUES - COMPARISON WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:39
|
作者
MUDDIMAN, DC
GUSEV, AI
STOPPEKLANGNER, K
PROCTOR, A
HERCULES, DM
TATA, P
VENKATARAMANAN, R
DIVEN, W
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,DEPT PHARMACEUT SCI,PITTSBURGH,PA 15213
[3] UNIV PITTSBURGH,DEPT PATHOL,PITTSBURGH,PA 15213
来源
JOURNAL OF MASS SPECTROMETRY | 1995年 / 30卷 / 10期
关键词
D O I
10.1002/jms.1190301013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simultaneous quantification of cyclosporin A (CsA) and its major metabolite (AM1) in blood has been achieved using time-of-flight secondary-ion mass spectrometry (TOF-SIMS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF-MS). Previous investigations indicated that spectral interferences exist in the analysis of CsA blood samples by the above methods, In TOF-SIMS, interference is caused by overlap of the Ag-cationized internal standard, cyclosporin D (CsD), with the Ag-cationized metabolite, AM1. To resolve this interference and obtain quantitative information, cross-correlation analysis was applied to the TOF-SIMS data, Application of damped non-linear least squares curve-fitting was carried out to resolve an interference in the MALDI/TOF-MS data due to multiple cationization products (i.e. Na and K), Measurement of standard samples indicates that the minimum accuracy (95% confidence level) of the TOF-SIMS method was better than 9% for CsA and 13% for AM1 using only one standard curve. Similarly, the minimum accuracy of the MALDI/TOF-MS method was determined to be 14% for CsA and better than 25% for AM1. Blood samples obtained from transplant patients receiving CsA were analyzed by polyclonal fluorescence polarization immunoassay, highperformance liquid chromatography (HPLC), and by both TOF-MS methods, Both TOF-MS results for CsA and mono-hydroxylated CsA are in good agreement with the HPLC results.
引用
收藏
页码:1469 / 1479
页数:11
相关论文
共 50 条
  • [1] Simultaneous quantification of cyclosporin a and its major metabolites by time-of-flight secondary-ion mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry utilizing data analysis techniques: Comparison with high-performance liquid chromatography
    Muddiman, D.C.
    Gusev, A.I.
    Stoppek-Langner, K.
    Proctor, A.
    Hercules, D.M.
    Tata, P.
    Venkataramanan, R.
    Diven, W.
    Journal of Mass Spectrometry, 1995, 30 (10):
  • [2] AEROSOL MATRIX-ASSISTED LASER-DESORPTION IONIZATION FOR LIQUID-CHROMATOGRAPHY TIME-OF-FLIGHT MASS-SPECTROMETRY
    MURRAY, KK
    LEWIS, TM
    BEESON, MD
    RUSSELL, DH
    ANALYTICAL CHEMISTRY, 1994, 66 (10) : 1601 - 1609
  • [3] ENHANCED MASS RESOLUTION IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION LINEAR TIME-OF-FLIGHT MASS-SPECTROMETRY
    SCHUERCH, S
    SCHAER, M
    BOERNSEN, KO
    SCHLUNEGGER, UP
    BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (11) : 695 - 700
  • [4] IMPROVED MASS ACCURACY IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF PEPTIDES
    VORM, O
    MANN, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) : 955 - 958
  • [5] MATRIX-ASSISTED LASER DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF UNDERIVATIZED AND PERMETHYLATED GANGLIOSIDES
    JUHASZ, P
    COSTELLO, CE
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (08) : 785 - 796
  • [6] MATRIX-ASSISTED LASER-DESORPTION IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF SYNTHETIC POLYESTERS
    BLAIS, JC
    TESSIER, M
    BOLBACH, G
    REMAUD, B
    ROZES, L
    GUITTARD, J
    BRUNOT, A
    MARECHAL, E
    TABET, JC
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 144 (1-2): : 131 - 138
  • [7] MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF PACLITAXEL AND RELATED TAXANES
    GIMON, ME
    KINSEL, GR
    EDMONDSON, RD
    RUSSELL, DH
    PROUT, TR
    EWALD, HA
    JOURNAL OF NATURAL PRODUCTS, 1994, 57 (10): : 1404 - 1410
  • [8] ION DETECTION LIMITATIONS TO MASS RESOLUTION IN MATRIX-ASSISTED LASER DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY
    BROWN, RS
    GILFRICH, NL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) : 690 - 696
  • [9] SURFACTANT ANALYSIS BY MATRIX-ASSISTED LASER-DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY
    THOMSON, B
    WANG, ZY
    PAINE, A
    RUDIN, A
    LAJOIE, G
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1995, 72 (01) : 11 - 15
  • [10] MATRIX-ASSISTED LASER-DESORPTION IONIZATION OF AEROSOLS FOR LIQUID-CHROMATOGRAPHY TOF MASS-SPECTROMETRY
    MURRAY, KK
    LEWIS, TM
    BEESON, MD
    RUSSELL, DH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 42 - ANYL