MYOCARDIAL CLEARANCE OF TC-99M HEXAKIS-2-METHOXY-2-METHYLPROPYL ISONITRILE (MIBI) IN PATIENTS WITH CORONARY-ARTERY DISEASE

被引:21
作者
FRANCESCHI, M
GUIMOND, J
ZIMMERMAN, RE
PICARD, MV
ENGLISH, RJ
CARVALHO, PA
TUMEH, SS
HOLMAN, BL
机构
[1] BRIGHAM & WOMENS HOSP,DEPT RADIOL,75 FRANCIS ST,BOSTON,MA 02115
[2] HARVARD UNIV,SCH MED,DEPT RADIOL,BOSTON,MA 02115
关键词
D O I
10.1097/00003072-199005000-00005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial clearance of the new cationic, lypophillic myocardial perfusion agent, Tc-99m-hexakis-2-methoxy-2- methylpropyl isonitrile (MIBI) was studied in nine patients with coronary artery disease. Regional time-activity curves were determined from serial postxercise myocardial SPECT images after a single dose of Tc-99m MIBI. There were significant differences between the clearance rates from normal and ischemic myocardium. Tc-99m MIBI washout from normal myocardium was 27 ± 8% by 6 hours after injection. Clearance from mild myocardial defects (initial activity greater than 60% of the activity in normal myocardium) was 16% by 6 hours in six patients. No washout was detected by 6 hours in the three patients with severe myocardial defects. The ratio between the activity in ischemic and normal myocardium increased from 0.70 ± 0.08 to 0.80 ± 0.13 and 0.84 ± 0.13 at 4 and 6 hours after injection in the patients with mild defects. In the patients with large defects, the ratio increased from 0.42 ± 0.09 to 0.54 ± 0.07 at 6 hours. It is concluded that, while redistribution is substantially slower than with TI-201, image interpretation and data evaluation should be approached cautiously when imaging is delayed 4 hours or more after injection of Tc-99m MIBI. Quantitative techniques aimed at evaluating the extent and intensity of myocardial ischemia wil be particularly affected.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 21 条
  • [1] NEW MYOCARDIAL PERFUSION IMAGING AGENTS - DESCRIPTION AND APPLICATIONS
    HEO, J
    HERMANN, GA
    ISKANDRIAN, AS
    ASKENASE, A
    SEGAL, BL
    [J]. AMERICAN HEART JOURNAL, 1988, 115 (05) : 1111 - 1117
  • [2] QUANTITATION OF PERFUSED MYOCARDIAL MASS USING T1-201 AND EMISSION COMPUTED-TOMOGRAPHY
    HOLMAN, BL
    MOORE, SC
    SHULKIN, PM
    KIRSCH, CM
    ENGLISH, RJ
    HILL, TC
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 322 - 326
  • [3] HOLMAN BL, 1986, J NUCL MED, V27, P1172
  • [4] HOLMAN BL, 1984, J NUCL MED, V25, P1350
  • [5] HOLMAN BL, 1987, J NUCL MED, V28, P13
  • [6] HOLMAN BL, 1988, HEART DISEASE, P311
  • [7] COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS
    KIAT, H
    MADDAHI, J
    ROY, LT
    VANTRAIN, K
    FRIEDMAN, J
    RESSER, K
    BERMAN, DS
    [J]. AMERICAN HEART JOURNAL, 1989, 117 (01) : 1 - 11
  • [8] LI QS, 1988, J NUCL MED, V29, P1539
  • [9] NONINVASIVE IDENTIFICATION OF LEFT MAIN AND TRIPLE VESSEL CORONARY-ARTERY DISEASE - IMPROVED ACCURACY USING QUANTITATIVE-ANALYSIS OF REGIONAL MYOCARDIAL STRESS-DISTRIBUTION AND WASHOUT OF TL-201
    MADDAHI, J
    ABDULLA, A
    GARCIA, EV
    SWAN, HJC
    BERMAN, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (01) : 53 - 60
  • [10] MCKUSICK K, 1986, J NUCL MED, V27, P878