QUANTIFICATION OF COMPLEX FLOW USING MR PHASE IMAGING - A STUDY OF PARAMETERS INFLUENCING THE PHASE-VELOCITY RELATION

被引:56
|
作者
STAHLBERG, F
SONDERGAARD, L
THOMSEN, C
HENRIKSEN, O
机构
[1] Danish Research Center for Magnetic Resonance, Copenhagen University, Copenhagen
[2] Department of Radiation Physics, Lund University Hospital, Lund
关键词
MR; FLOW; STENOSIS; PHASE IMAGE; QUANTIFICATION;
D O I
10.1016/0730-725X(92)90368-A
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, we describe how motion-induced phase angle is affected by different flow models and imaging parameters when using the MR flow phase mapping technique. In a phantom with straight as well as constricted tubes, simulating healthy and stenotic vessels, nonpulsatile flow in the velocity range 0-1 m/sec was maintained. The phase/velocity relation was studied for various degrees of complex flow caused by the constriction, and regions with a breakdown in linearity were determined. Further studies in these regions were made regarding the influence of pulse sequence parameters on the phase/velocity relation. The results showed that in poststenotic areas characterized by so-called separated flow, the phase/velocity relation became nonlinear due to dephasing effects. In regions with fully developed turbulent flow in straight tubes, however, no breakdown in linearity was observed. Parameters seen to have a substantial influence on the phase/velocity relation were first- and second-order velocity encoding and voxel size. Finally, a pilot in vivo demonstration of complex flow was done using a sequence designed to be robust with respect to linearity of the phase/velocity relation. The results indicate that the MR phase mapping technique can be used to measure flow quantitatively in regions with complex flow. This opens possibilities for future clinical use of the technique in the study of areas of complex flow such as valvular heart disease.
引用
收藏
页码:13 / 23
页数:11
相关论文
共 50 条
  • [41] Addressing phase errors in fat-water imaging using a mixed magnitude/complex fitting method
    Hernando, D.
    Hines, C. D. G.
    Yu, H.
    Reeder, S. B.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 638 - 644
  • [42] SKELETAL-MUSCLE CONTRACTION - ANALYSIS WITH USE OF VELOCITY DISTRIBUTIONS FROM PHASE-CONTRAST MR-IMAGING
    DRACE, JE
    PELC, NJ
    RADIOLOGY, 1994, 193 (02) : 423 - 429
  • [43] Feasibility of Phase Velocity Imaging Using Multi Frequency Oscillation-Shear Wave Elastography
    Hossain, Md Murad
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (02) : 607 - 620
  • [44] Reducing data acquisition times in phase-encoded velocity imaging using compressed sensing
    Holland, D. J.
    Malioutov, D. M.
    Blake, A.
    Sederman, A. J.
    Gladden, L. F.
    JOURNAL OF MAGNETIC RESONANCE, 2010, 203 (02) : 236 - 246
  • [45] Phase-Contrast MR Flow Imaging: A Tool to Determine Hepatic Hemodynamics in Rats with a Healthy, Fibrotic, or Cirrhotic Liver
    Schaffner, Denise
    von Elverfeldt, Dominik
    Deibert, Peter
    Lazaro, Adhara
    Merfort, Irmgard
    Lutz, Lisa
    Neubauer, Jakob
    Baumstark, Manfred W.
    Kreisel, Wolfgang
    Reichardt, Wilfried
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1526 - 1534
  • [46] Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study
    Park, Jieun
    Kim, Junghun
    Chang, Yongmin
    Youn, Sung Won
    Lee, Hui Joong
    Kang, Eun-Ju
    Lee, Ki-Nam
    Suchanek, Vojtech
    Hyun, Sinjae
    Lee, Jongmin
    COMPUTER ASSISTED SURGERY, 2019, 24 : 3 - 12
  • [47] Comparison of blood velocity measurements between ultrasound Doppler and accelerated phase-contrast MR angiography in small arteries with disturbed flow
    Jiang, Jingfeng
    Strother, Charles
    Johnson, Kevin
    Baker, Sara
    Consigny, Dan
    Wieben, Oliver
    Zagzebski, James
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1755 - 1773
  • [48] Velocity Measurements in the Middle Cerebral Arteries of Healthy Volunteers Using 3D Radial Phase-Contrast HYPRFlow: Comparison with Transcranial Doppler Sonography and 2D Phase-Contrast MR Imaging
    Chang, W.
    Landgraf, B.
    Johnson, K. M.
    Kecskemeti, S.
    Wu, Y.
    Velikina, J.
    Rowley, H.
    Wieben, O.
    Mistretta, C.
    Turski, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) : 54 - 59
  • [49] A Numerical Study on Conductivity Estimation of the Human Head in the Low Frequency Domain Using Induced Current MR Phase Imaging EIT With Multiple Gradients
    De Geeter, Nele
    Crevecoeur, Guillaume
    Dupre, Luc
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (09) : 5004 - 5010
  • [50] Radiofrequency saturation induced bias in aqueductal cerebrospinal fluid flow quantification obtained using two-dimensional cine phase contrast magnetic resonance imaging
    Ragunathan, Sudarshan
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2067 - 2076