QUANTIFICATION OF COMPLEX FLOW USING MR PHASE IMAGING - A STUDY OF PARAMETERS INFLUENCING THE PHASE-VELOCITY RELATION

被引:56
|
作者
STAHLBERG, F
SONDERGAARD, L
THOMSEN, C
HENRIKSEN, O
机构
[1] Danish Research Center for Magnetic Resonance, Copenhagen University, Copenhagen
[2] Department of Radiation Physics, Lund University Hospital, Lund
关键词
MR; FLOW; STENOSIS; PHASE IMAGE; QUANTIFICATION;
D O I
10.1016/0730-725X(92)90368-A
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, we describe how motion-induced phase angle is affected by different flow models and imaging parameters when using the MR flow phase mapping technique. In a phantom with straight as well as constricted tubes, simulating healthy and stenotic vessels, nonpulsatile flow in the velocity range 0-1 m/sec was maintained. The phase/velocity relation was studied for various degrees of complex flow caused by the constriction, and regions with a breakdown in linearity were determined. Further studies in these regions were made regarding the influence of pulse sequence parameters on the phase/velocity relation. The results showed that in poststenotic areas characterized by so-called separated flow, the phase/velocity relation became nonlinear due to dephasing effects. In regions with fully developed turbulent flow in straight tubes, however, no breakdown in linearity was observed. Parameters seen to have a substantial influence on the phase/velocity relation were first- and second-order velocity encoding and voxel size. Finally, a pilot in vivo demonstration of complex flow was done using a sequence designed to be robust with respect to linearity of the phase/velocity relation. The results indicate that the MR phase mapping technique can be used to measure flow quantitatively in regions with complex flow. This opens possibilities for future clinical use of the technique in the study of areas of complex flow such as valvular heart disease.
引用
收藏
页码:13 / 23
页数:11
相关论文
共 50 条
  • [31] Phase contrast MR imaging measurements of blood flow in healthy human cerebral vessel segments
    MacDonald, Matthew Ethan
    Frayne, Richard
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (07) : 1517 - 1527
  • [32] Common Carotid Artery Volume Flow: A Comparison Study between Ultrasound Vector Flow Imaging and Phase Contrast Magnetic Resonance Imaging
    Brandt, Andreas Hjelm
    Olesen, Jacob Bjerring
    Moshavegh, Ramin
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    Hansen, Kristoffer Lindskov
    NEUROLOGY INTERNATIONAL, 2021, 13 (03) : 269 - 278
  • [33] Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging
    de Verdier, Maria Correia
    Wikstrom, Johan
    NEURORADIOLOGY, 2016, 58 (05) : 521 - 531
  • [34] AUTOMATIC ENHANCEMENT, ANIMATION, AND SEGMENTATION OF FLOW IN PERIPHERAL ARTERIES FROM MR PHASE-SHIFT VELOCITY MAPPING
    MOHIADDIN, RH
    YANG, GZ
    BURGER, P
    FIRMIN, DN
    LONGMORE, DB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (02) : 176 - 181
  • [35] Measurement of Turbulent Kinetic Energy in Hypertrophic Cardiomyopathy Using Triple-velocity Encoding 4D Flow MR Imaging
    Iwata, Kotomi
    Sekine, Tetsuro
    Matsuda, Junya
    Tachi, Masaki
    Imori, Yoichi
    Amano, Yasuo
    Ando, Takahiro
    Obara, Makoto
    Crelier, Gerard
    Ogawa, Masashi
    Takano, Hitoshi
    Kumita, Shinichiro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (01) : 39 - 48
  • [36] Characterization of complex flow patterns in the ascending aorta in patients with aortic regurgitation using conventional phase-contrast velocity MRI
    Bech-Hanssen, Odd
    Svensson, Frida
    Polte, Christian L.
    Johnsson, Ase A.
    Gao, Sinsia A.
    Lagerstrand, Kerstin M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (03) : 419 - 429
  • [37] Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Arheden, H
    Ståhlberg, F
    Higgins, CB
    Saeed, M
    RADIOLOGY, 2000, 217 (02) : 487 - 493
  • [38] Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring
    Giese, Daniel
    Haeberlin, Maximilian
    Barmet, Christoph
    Pruessmann, Klaas P.
    Schaeffter, Tobias
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1294 - 1302
  • [39] SPARSE RECOVERY OF COMPLEX PHASE-ENCODED VELOCITY IMAGES USING ITERATIVE THRESHOLDING
    Roberts, Tim
    Kingsbury, Nick
    Holland, Daniel J.
    2013 20TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2013), 2013, : 350 - 354
  • [40] Quantification of breast tumor microvascular permeability with feruglose-enhanced MR imaging: Initial phase II multicenter trial
    Daldrup-Link, HE
    Rydland, J
    Helbich, TH
    Bjornerud, A
    Turetschek, K
    Kvistad, KA
    Kaindl, E
    Link, TM
    Staudacher, K
    Shames, D
    Brasch, RC
    Haraldseth, O
    Rummeny, EJ
    RADIOLOGY, 2003, 229 (03) : 885 - 892