QUANTIFICATION OF COMPLEX FLOW USING MR PHASE IMAGING - A STUDY OF PARAMETERS INFLUENCING THE PHASE-VELOCITY RELATION

被引:56
|
作者
STAHLBERG, F
SONDERGAARD, L
THOMSEN, C
HENRIKSEN, O
机构
[1] Danish Research Center for Magnetic Resonance, Copenhagen University, Copenhagen
[2] Department of Radiation Physics, Lund University Hospital, Lund
关键词
MR; FLOW; STENOSIS; PHASE IMAGE; QUANTIFICATION;
D O I
10.1016/0730-725X(92)90368-A
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, we describe how motion-induced phase angle is affected by different flow models and imaging parameters when using the MR flow phase mapping technique. In a phantom with straight as well as constricted tubes, simulating healthy and stenotic vessels, nonpulsatile flow in the velocity range 0-1 m/sec was maintained. The phase/velocity relation was studied for various degrees of complex flow caused by the constriction, and regions with a breakdown in linearity were determined. Further studies in these regions were made regarding the influence of pulse sequence parameters on the phase/velocity relation. The results showed that in poststenotic areas characterized by so-called separated flow, the phase/velocity relation became nonlinear due to dephasing effects. In regions with fully developed turbulent flow in straight tubes, however, no breakdown in linearity was observed. Parameters seen to have a substantial influence on the phase/velocity relation were first- and second-order velocity encoding and voxel size. Finally, a pilot in vivo demonstration of complex flow was done using a sequence designed to be robust with respect to linearity of the phase/velocity relation. The results indicate that the MR phase mapping technique can be used to measure flow quantitatively in regions with complex flow. This opens possibilities for future clinical use of the technique in the study of areas of complex flow such as valvular heart disease.
引用
收藏
页码:13 / 23
页数:11
相关论文
共 50 条
  • [1] Peak velocity and flow quantification validation for sensitivity-encoded phase-contrast MR imaging
    Lew, Calvin D.
    Alley, Marcus T.
    Bammer, Roland
    Spielman, Daniel M.
    Chan, Frandics P.
    ACADEMIC RADIOLOGY, 2007, 14 (03) : 258 - 269
  • [2] REAL-TIME FLOOD FLOW IMAGING BY SPIRAL SCAN PHASE-VELOCITY MAPPING
    GATEHOUSE, PD
    FIRMIN, DN
    COLLINS, S
    LONGMORE, DB
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) : 504 - 512
  • [3] SEMIAUTOMATED METHOD FOR NOISE-REDUCTION AND BACKGROUND PHASE ERROR CORRECTION IN MR PHASE-VELOCITY DATA
    WALKER, PG
    CRANNEY, GB
    SCHEIDEGGER, MB
    WASELESKI, G
    POHOST, GM
    YOGANATHAN, AP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 521 - 530
  • [4] GLOBAL LEFT-VENTRICULAR PERFUSION - NONINVASIVE MEASUREMENT WITH CINE MR IMAGING AND PHASE-VELOCITY MAPPING OF CORONARY VENOUS OUTFLOW
    VANROSSUM, AC
    VISSER, FC
    HOFMAN, MBM
    GALJEE, MA
    WESTERHOF, N
    VALK, J
    RADIOLOGY, 1992, 182 (03) : 685 - 691
  • [5] MITRAL AND AORTIC VALVULAR FLOW - QUANTIFICATION WITH MR PHASE MAPPING
    SONDERGAARD, L
    THOMSEN, C
    STAHLBERG, F
    GYMOESE, E
    LINDVIG, K
    HILDEBRANDT, P
    HENRIKSEN, O
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 295 - 302
  • [6] WAVE SPEED DURING MAXIMAL EXPIRATORY FLOW AND PHASE-VELOCITY FROM FORCED-OSCILLATIONS
    SUKI, B
    PEDERSEN, OF
    HABIB, RH
    JACKSON, AC
    RESPIRATION PHYSIOLOGY, 1995, 102 (01): : 39 - 49
  • [7] POPLITEAL AND TIBIOPERONEAL ARTERIES - FEASIBILITY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY AND PHASE-VELOCITY MAPPING
    CAPUTO, GR
    MASUI, T
    GOODING, GAW
    CHANG, JM
    HIGGINS, CB
    RADIOLOGY, 1992, 182 (02) : 387 - 392
  • [8] Comparison of Blood Flow Velocity Quantification by 4D Flow MR Imaging with Ultrasound at the Carotid Bifurcation
    Harloff, A.
    Zech, T.
    Wegent, F.
    Strecker, C.
    Weiller, C.
    Markl, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (07) : 1407 - 1413
  • [9] Quantification of blood flow in the superior ophthalmic vein using phase contrast magnetic resonance imaging
    Promelle, Veronique
    Bouzerar, Roger
    Milazzo, Solange
    Baledent, Olivier
    EXPERIMENTAL EYE RESEARCH, 2018, 176 : 40 - 45
  • [10] VELOCITY AND FLOW QUANTITATION IN THE SUPERIOR SAGITTAL SINUS WITH UNGATED AND CINE (GATED) PHASE-CONTRAST MR-IMAGING
    JORDAN, JE
    PELC, NJ
    ENZMANN, DR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (01): : 25 - 28