Operation of a Two-Phase Reverse Loop Thermosyphon

被引:3
作者
Tsai, Meng-Chang [1 ]
Kang, Shung-Wen [2 ]
Li, Heng-Yi [1 ]
Tsai, Wen-Fa [1 ]
机构
[1] Inst Nucl Energy Res, Taoyuan 325, Taiwan
[2] Tamkang Univ Tamsui, Dept Mech & Elect Mech Engn, Fujisawa, Kanagawa 251, Japan
来源
JOURNAL OF APPLIED SCIENCE AND ENGINEERING | 2015年 / 18卷 / 03期
关键词
Reverse-loop; Thermosyphon; Heat Transfer Downward; Cyclic Operation;
D O I
10.6180/jase.2015.18.3.06
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A prototype two-phase reverse-loop thermosyphon (RLT) was fabricated to transport thermal energy downwards to a thermal storage tank. The effect the filling ratio exerted on the thermal performance of the RTL was investigated by conducting experiments that were performed by a range between 47% and 63%. The prototype device comprised an evaporator, a condenser, a reservoir (preheater), and pipes connecting each of the components. The heat transport height was 1500 mm from the evaporator to the bottom of the condenser. Methanol with a concentration of 95% was used as the working fluid. The temperature distribution, temperature difference between the evaporator and condenser, and thermal resistance of the thermosyphon were measured. In addition, a cyclic case, in which the power in coils was alternately switched on and off according to a square wave function was studied. The results indicated that the maximal thermal performance of the RLT occurred when the filling ratio was 60% and the input power was 660W.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 5 条