NOISE-POLLUTION IN THE OPERATING-THEATER

被引:142
作者
HODGE, B [1 ]
THOMPSON, JF [1 ]
机构
[1] ROYAL PRINCE ALFRED HOSP, SYDNEY, AUSTRALIA
关键词
D O I
10.1016/0140-6736(90)90486-O
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sound levels during a typical major operation were measured to identify the main sources of noise in the operating theatre. Although overall sound levels were within the recommended levels for a satisfactory working environment, loud intermittent noises of up to 108 dB were emitted from sources such as suckers, "intercoms", and alarms on anaesthetic monitoring devices. The noisiest time was usually during the preparation period of the operation; during surgery, noise levels were much higher than levels of normal speech between staff. Preferred speech interference levels were often exceeded which made communication difficult and sometimes impossible. Communication and concentration were also disrupted by unnecessary background conversation. © 1990.
引用
收藏
页码:891 / 894
页数:4
相关论文
共 18 条
  • [11] AUDITORY ALARMS DURING ANESTHESIA MONITORING
    KESTIN, IG
    MILLER, BR
    LOCKHART, CH
    [J]. ANESTHESIOLOGY, 1988, 69 (01) : 106 - 109
  • [12] Kryter K. D., 1970, EFFECTS NOISE MAN
  • [13] Mori H, 1979, JAP J ANAESTHESIOL, V10, P1102
  • [14] OSZEWSKI DA, 1976, M MID W PSYCHOL ASS
  • [15] NOISE IN OPERATING ROOM
    SHAPIRO, RA
    BERLAND, T
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1972, 287 (24) : 1236 - &
  • [16] WALKER JG, 1975, HDB NOISE ASSESSMENT, V7, P185
  • [17] 1977, ACOUSTICS METHODS AS
  • [18] 1977, AMBIENT SOUND LEVELS