CONTRAST-ENHANCED ECHO-PLANAR MR-IMAGING OF MYOCARDIAL PERFUSION - PRELIMINARY-STUDY IN HUMANS

被引:87
作者
EDELMAN, RR [1 ]
LI, W [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
HEART; MR; 51.121416; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; PERFUSION STUDY; 51.12144; MYOCARDIUM; BLOOD SUPPLY;
D O I
10.1148/radiology.190.3.8115626
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the usefulness of T1- and T2*-weighted echo-planar magnetic resonance (MR) imaging in the assessment of cardiac perfusion. MATERIALS AND METHODS: Sixteen subjects underwent MR imaging. Fifteen subjects were healthy volunteers and one had coronary artery disease. T2%-weighted echo-planar imaging with free induction decay was performed in II subjects and TI-weighted inversion-recovery spin-echo echo-planar imaging was performed in five. Images were obtained before and after administration of gadopentetate dimeglumine. RESULTS: The contrast-to-noise ratio for pre- and postcontrast T2*-weighted images obtained with an echo time of 16 msec (n = 8) was -9.9 +/- 3.4, and the contrast enhancement ratio was -0.37 +/- 0.07. The values for T2*-weighted images obtained with an echo time of 30 msec (n = 3) were -9.5 +/- 6.8 and 0.44 +/- 0.02, respectively. For TI-weighted echo-planar imaging, the values were 26.7 +/- 8.0 and. 4.6 +/- 2.8, respectively. CONCLUSION: Inversion-recovery spin-echo echo-planar imaging provides excellent temporal resolution, myocardial detail, and myocardium-blood pool contrast, with minimal artifact. It is presently the technique of choice for the MR imaging evaluation of myocardial perfusion.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 50 条
  • [11] BENIGN AND MALIGNANT BREAST-LESIONS - DIFFERENTIATION WITH ECHO-PLANAR MR-IMAGING
    HULKA, CA
    SMITH, BL
    SGROI, DC
    TAN, LJ
    EDMISTER, WB
    SEMPLE, JP
    CAMPBELL, T
    KOPANS, DB
    BRADY, TJ
    WEISSKOFF, RM
    RADIOLOGY, 1995, 197 (01) : 33 - 38
  • [12] CONTRAST-ENHANCED MR-IMAGING OF INTRAHEPATIC CHOLANGIOCARCINOMA - PATHOLOGICAL CORRELATION STUDY
    MURAKAMI, T
    NAKAMURA, H
    TSUDA, K
    ISHIDA, T
    TOMODA, K
    HORI, S
    MONDEN, M
    KANAI, T
    WAKASA, K
    SAKURAI, M
    KOZUKA, T
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02): : 165 - 170
  • [13] DIFFERENTIAL-DIAGNOSIS OF FOCAL LIVER-LESIONS - ROLE OF SPIN-ECHO AND CONTRAST-ENHANCED DYNAMIC MR-IMAGING
    YAMASHITA, Y
    HATANAKA, Y
    YAMAMOTO, H
    ARAKAWA, A
    MATSUKAWA, T
    MIYAZAKI, T
    TAKAHASHI, M
    RADIOLOGY, 1994, 193 (01) : 59 - 65
  • [14] EXPERIMENTAL GASTROINTESTINAL HEMORRHAGE - DETECTION WITH CONTRAST-ENHANCED MR-IMAGING AND SCINTIGRAPHY
    GUPTA, H
    WEISSLEDER, R
    BOGDANOV, AA
    BRADY, TJ
    RADIOLOGY, 1995, 196 (01) : 239 - 244
  • [15] DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF FIBROLAMELLAR HEPATOCELLULAR-CARCINOMA
    CORRIGAN, K
    SEMELKA, RC
    ABDOMINAL IMAGING, 1995, 20 (02): : 122 - 125
  • [16] CONTRAST-ENHANCED MR IMAGING OF THE LUNG - ASSESSMENTS OF VENTILATION AND PERFUSION
    BERTHEZENE, Y
    VEXLER, V
    CLEMENT, O
    MUHLER, A
    MOSELEY, ME
    BRASCH, RC
    RADIOLOGY, 1992, 183 (03) : 667 - 672
  • [17] QUANTITATIVE CONTRAST-ENHANCED MR-IMAGING OF THE OPTIC-NERVE
    SIMON, JH
    RUBINSTEIN, D
    BROWN, M
    YUH, W
    BIRCHIENSEN, M
    SZUMOWSKI, J
    STEARS, J
    ACTA RADIOLOGICA, 1994, 35 (06) : 526 - 531
  • [18] Dynamic Contrast-Enhanced Perfusion MR Imaging With SPIO A Pilot Study
    Amemiya, Shiori
    Akahane, Masaaki
    Aoki, Shigeki
    Abe, Osamu
    Kamada, Kyosuke
    Saito, Nobuyuki
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 503 - 508
  • [19] LYMPHOCYTIC ADENOHYPOPHYSITIS - CONTRAST-ENHANCED MR-IMAGING IN 5 CASES
    AHMADI, J
    MEYERS, GS
    SEGALL, HD
    SHARMA, OP
    HINTON, DR
    RADIOLOGY, 1995, 195 (01) : 30 - 34
  • [20] DIAGNOSIS OF OSTEOMYELITIS - UTILITY OF FAT-SUPPRESSED CONTRAST-ENHANCED MR-IMAGING
    MORRISON, WB
    SCHWEITZER, ME
    BOCK, GW
    MITCHELL, DG
    HUME, EL
    PATHRIA, MN
    RESNICK, D
    RADIOLOGY, 1993, 189 (01) : 251 - 257