Reliability of a digital weighing scale relative to the Nintendo Wii in measuring limb load asymmetry

被引:1
作者
Kumar, Senthil N. S. [1 ]
Joseph, Leonard H. [1 ]
Omar, Baharudin [2 ]
Sulaiman, Riza [3 ]
Nor, Hamdan M. Y. [4 ]
Htwe, Ohnmar [4 ]
Hamidun, Nursalbiyah [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Hlth Sci, Sch Rehabil Sci, Bangi 43600, Malaysia
[2] Univ Kebangsaan Malaysia, Fac Hlth Sci, Bangi 43600, Malaysia
[3] Univ Kebangsaan Malaysia, Fac Informat Sci & Technol, Bangi 43600, Malaysia
[4] Univ Kebangsaan Malaysia, Med Ctr, Fac Med, Dept Orthoped & Traumatol, Kuala Lumpur, Malaysia
关键词
Reliability; Digital weighing scale; Nintendo Wii; Limb loading; Osteoarthritis;
D O I
10.12968/ijtr.2015.22.2.74
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background/Aims: Limb load asymmetry (LLA) is common in clinical conditions related to the lower limbs such as degenerative joint disease, soft tissue injuries, joint replacements, amputations and stroke. However, the measurement of LLA is limited in clinical practice as the equipment used is expensive and not readily available in most health care settings. The digital weighing scale is proposed as an inexpensive alternative method of measuring LLA and the objective of this study was to investigate the reliability and accuracy of a digital weighing scale relative to the Nintendo Wii in measuring limb load asymmetry during static standing. Methods: Twenty-four participants (12 participants with knee osteoarthritis (OA) and 12 healthy participants) were recruited through convenient sampling from a public university teaching hospital. The participants were required to perform a quiet standing task during the measurement of LLA. The measurements were taken over three trials during both eyes-open (EO) and eyes-closed (EC) resting conditions. LLA was measured in kilograms and computed with a symmetry index. Intra-class correlation coefficient (ICC) (3, 1) analysis, standard error of measurement and coefficient of variation were performed to assess reliability. The Bland-Altman plot was used to test the degree of agreement between digital weighing scales and the Nintendo Wii. Results: The digital weighing scale showed an excellent reliability of 0.983 and 0.988 in EC and EO conditions, respectively. The Bland-Altman plot showed good agreement between digital weighing scales and the Nintendo Wii in measuring LLA. Conclusions: The digital weighing scale is a reliable tool to measure LLA and has excellent potential to be used in clinical settings.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 23 条
[1]  
Adegoke B O A, 2012, Glob J Health Sci, V4, P87, DOI 10.5539/gjhs.v4n2p87
[2]   Weight distribution symmetry during the sit-to-stand movement of unilateral transtibial amputees [J].
Agrawal, Vibhor ;
Gailey, Robert ;
Gaunaurd, Ignacio ;
Gailey, Robert, III ;
O'Toole, Christopher .
ERGONOMICS, 2011, 54 (07) :656-664
[3]  
Bohannon R W, 1991, Aust J Physiother, V37, P19, DOI 10.1016/S0004-9514(14)60530-4
[4]   LOWER-EXTREMITY WEIGHT BEARING UNDER VARIOUS STANDING CONDITIONS IN INDEPENDENTLY AMBULATORY PATIENTS WITH HEMIPARESIS [J].
BOHANNON, RW ;
LARKIN, PA .
PHYSICAL THERAPY, 1985, 65 (09) :1323-1325
[5]   Reliability of the TekScan MatScan® system for the measurement of postural stability in older people with rheumatoid arthritis [J].
Brenton-Rule, Angela ;
Mattock, Joshua ;
Carroll, Matthew ;
Dalbeth, Nicola ;
Bassett, Sandra ;
Menz, Hylton B. ;
Rome, Keith .
JOURNAL OF FOOT AND ANKLE RESEARCH, 2012, 5
[6]  
Caldwell C, 1986, PHYSIOTHERAPY PRACTI, V2, P109
[7]   Weight-Bearing Asymmetry in Relation to Measures of Impairment and Functional Mobility for People With Knee Osteoarthritis [J].
Christiansen, Cory L. ;
Stevens-Lapsley, Jennifer E. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (10) :1524-1528
[8]   Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance [J].
Clark, Ross A. ;
Bryant, Adam L. ;
Pua, Yonghao ;
McCrory, Paul ;
Bennell, Kim ;
Hunt, Michael .
GAIT & POSTURE, 2010, 31 (03) :307-310
[9]   Reliability of an inexpensive and portable dynamic weight bearing asymmetry assessment system incorporating dual Nintendo Wii Balance Boards [J].
Clark, Ross Allan ;
McGough, Rian ;
Paterson, Kade .
GAIT & POSTURE, 2011, 34 (02) :288-291
[10]   Design, Analysis, and Interpretation of Method-Comparison Studies [J].
Hanneman, Sandra K. .
AACN ADVANCED CRITICAL CARE, 2008, 19 (02) :223-234