Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy

被引:3
作者
Liu, Hong-Wei [1 ,2 ]
Olivotto, Ivo [3 ,4 ]
Lau, Harold [3 ,4 ]
Nugent, Zoann [5 ]
Khan, Rao [6 ]
机构
[1] Cent Alberta Canc Ctr, Dept Radiat Oncol, Red Deer, AB, Canada
[2] Univ Alberta, Dept Oncol, Edmonton, AB, Canada
[3] Tom Baker Canc Clin, Dept Radiat Oncol, Calgary, AB, Canada
[4] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[5] CancerCare Manitoba, Epidemiol & Canc Registry, Winnipeg, MB, Canada
[6] Washington Univ, Sch Med, Dept Oncol, Radiat Oncol, St Louis, MO USA
关键词
Lung cancer; stereotactic body radiotherapy; Acuros XB; volumetric-modulated arc therapy; flattening filter free;
D O I
10.1016/j.jmir.2016.04.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the role of volumetric-modulated arc therapy (VMAT) combined with flattening filter free (FFF) beam delivery in lung stereotactic body radiotherapy (SBRT), using Acuros XB algorithm. Materials and methods: Ninety-eight stage I lung cancer cases treated with SBRT were included. Retrospectively, single arc, 6 MV VMAT with FFF and flattened field (FF) beam plans were generated using the identical optimization criteria with Acuros XB dose computation algorithm. Optimization constraints included target dose ratio of 50% prescription isodose volume to target (R50%) and maximal dose at 2 cm from the target (D2cm). Study parameters, including the number of monitor units (MUs), mean target dose, conformality number, and heterogeneity index of the target, R50%, D2cm, and mean dose to normal tissues were determined and compared for the two delivery modes. A paired matched t-test was used to compare the difference. The effect of tumor, patient and treatment mode (FFF vs. FF) on the difference of MUs obtained from the two delivery systems was statistically determined using linear regression analyses. Results: FFF beams required 6.9% (range -3.4% to 15.6%) more MUs and resulted in slightly higher values for mean target dose, R50% and D2cm (all P<.0001) compared with FF beams. Conformality number, homogeneity index of target, and mean dose to the normal body were similar between the two plans. Logistic regression analysis confirmed that VMAT with FFF mode, not the tumor or patient-specific parameters, caused the increase in MUs compared with FF beam delivery (P=.043). Conclusions: In lung SBRT, using VMAT with FFF beam required 7% more MUs compared with a VMAT with FF beam plan and provided similar target coverage. The low leakage dose advantage of FFF delivery is offset by the increased number of MU. The only advantage available to the FFF beams is their estimated faster delivery.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 23 条
[1]   PROSPECTIVE, RISK-ADAPTED STRATEGY OF STEREOTACTIC BODY RADIOTHERAPY FOR EARLY-STAGE NON-SMALL-CELL LUNG CANCER: RESULTS OF A PHASE II TRIAL [J].
Bral, Samuel ;
Gevaert, Thierry ;
Linthout, Nadine ;
Versmessen, Harijati ;
Collen, Christine ;
Engels, Benedikt ;
Verdries, Douwe ;
Everaert, Hendrik ;
Christian, Nicolas ;
De Ridder, Mark ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1343-1349
[2]   Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations [J].
Bush, K. ;
Gagne, I. M. ;
Zavgorodni, S. ;
Ansbacher, W. ;
Beckham, W. .
MEDICAL PHYSICS, 2011, 38 (04) :2208-2221
[3]   A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer [J].
Gasic, Daniel ;
Ohlhues, Lars ;
Brodin, N. Patrik ;
Fog, Lotte S. ;
Pommer, Tobias ;
Bangsgaard, Jens P. ;
Rosenschold, Per Munck A. F. .
ACTA ONCOLOGICA, 2014, 53 (08) :1005-1011
[4]   Early-stage lung cancer in elderly patients: A population-based study of changes in treatment patterns and survival in the Netherlands [J].
Haasbeek, C. J. A. ;
Palma, D. ;
Visser, O. ;
Lagerwaard, F. J. ;
Slotman, B. ;
Senan, S. .
ANNALS OF ONCOLOGY, 2012, 23 (10) :2743-2747
[5]   Outcomes of Stereotactic Ablative Radiotherapy for Centrally Located Early-Stage Lung Cancer [J].
Haasbeek, Cornelis J. A. ;
Lagerwaard, Frank J. ;
Slotman, Ben J. ;
Senan, Suresh .
JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (12) :2036-2043
[6]  
Hansen C. R., 2014, ACTA ONCOL, P1
[7]   Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer [J].
Hrbacek, Jan ;
Lang, Stephanie ;
Graydon, Shaun N. ;
Kloeck, Stephan ;
Riesterer, Oliver .
MEDICAL PHYSICS, 2014, 41 (03)
[8]   Flattening filter free beams in SBRT and IMRT: Dosimetric assessment of peripheral doses [J].
Kragl, Gabriele ;
Baier, Franziska ;
Lutz, Steffen ;
Albrich, David ;
Dalaryd, Marten ;
Kroupa, Bernhard ;
Wiezorek, Tilo ;
Knoos, Tommy ;
Georg, Dietmar .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (02) :91-101
[9]   Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy [J].
Liu, Hong-Wei ;
Nugent, Zoann ;
Clayton, Ravinder ;
Dunscombe, Peter ;
Lau, Harold ;
Khan, Rao .
ACTA ONCOLOGICA, 2014, 53 (03) :324-329
[10]   Volumetric modulated arc therapy with flattening filter free (FFF) beams for stereotactic body radiation therapy (SBRT) in patients with medically inoperable early stage non small cell lung cancer (NSCLC) [J].
Navarria, Pierina ;
Ascolese, Anna Maria ;
Mancosu, Pietro ;
Alongi, Filippo ;
Clerici, Elena ;
Tozzi, Angelo ;
Iftode, Cristina ;
Reggiori, Giacomo ;
Tomatis, Stefano ;
Infante, Maurizio ;
Alloisio, Marco ;
Testori, Alberto ;
Fogliata, Antonella ;
Cozzi, Luca ;
Morenghi, Emanuela ;
Scorsetti, Marta .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) :414-418