Distal Radius Fracture Treated by Internal Fixation with Plates, Screws and the RALCA (R) External Mini-fixator

被引:0
作者
Lopez Cuellar, Rafael [1 ]
Truffin Rodriguez, Yaniel [1 ]
Perez Alvarez, Yudit [1 ]
机构
[1] Hosp Gen Univ Dr Gustavo Aldereguia Lima, Cienfuegos 55100, Cienfuegos, Cuba
来源
MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS | 2016年 / 14卷 / 01期
关键词
radius fractures; hand injuries; fracture fixation; internal; internal fixators; bone plates; bone nails;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Distal radius fractures are very common in medical practice. In our service, we may not have the most widely used devices for fixation of these fractures at a given moment. For this reason, we must consider all possible combinations within our power to correct them since most of the time, it is impossible to maintain a fracture reduction using a single technique. We present the case of a 24-year-old female patient treated at the Dr. Gustavo Aldereguia Lima University General Hospital in Cienfuegos due to a displaced fracture of the left distal radius caused by impaction. It was successfully stabilized by internal fixation with plates, screws and the RALCA (R) external mini-fixator.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 13 条
[1]  
Elizondo H E, 2010, Acta Ortop Mex, V24, P312
[2]  
Fernandez D L, 1993, Instr Course Lect, V42, P73
[3]  
Geller L, 2009, CAN J SURG, V52, pE161
[4]  
Gomez-Gil I, 2014, MEDISUR, V12
[5]   Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures [J].
Kumbaraci M. ;
Kucuk L. ;
Karapinar L. ;
Kurt C. ;
Coskunol E. .
European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (2) :173-178
[6]   Volar long locking compression plate fixation for distal radius fractures with metaphyseal and diaphyseal extension [J].
Lee S.K. ;
Seo D.W. ;
Kim K.J. ;
Yang D.S. ;
Choy W.S. .
European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (4) :407-415
[7]   Fixation of Dorsally Displaced Distal Radius Fractures With Volar Plate [J].
Othman, Ahmed Y. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (05) :1416-1420
[8]  
Pattanashetty OB, 2013, KERALA J ORTHOPAEDIC, V26, P87
[9]   Analysis of the Complications of Palmar Plating Versus Extern It Fixation for Fractures of the Distal Radius [J].
Richard, Marc J. ;
Wartinbee, Daniel A. ;
Riboh, Jonathan ;
Miller, Michael ;
Leversedge, Fraser J. ;
Ruch, David S. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (10) :1614-1620
[10]   A Randomized Comparison of Volar Plate and External Fixation for Intra-Articular Distal Radius Fractures [J].
Roh, Young Hak ;
Lee, Beom Koo ;
Baek, Jong Ryoon ;
Noh, Jung Ho ;
Gong, Hyun Sik ;
Baek, Goo Hyun .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01) :34-41