MAGNETIC-RESONANCE, A NEW METHOD FOR MEASURING BLOOD-FLOW IN HEMODIALYSIS FISTULAS

被引:38
|
作者
OUDENHOVEN, LFIJ [1 ]
PATTYNAMA, PMT [1 ]
DEROOS, A [1 ]
SEEVERENS, HJJ [1 ]
REBERGEN, SA [1 ]
CHANG, PC [1 ]
机构
[1] UNIV HOSP LEIDEN,DEPT NEPHROL,2300 RC LEIDEN,NETHERLANDS
关键词
D O I
10.1038/ki.1994.116
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Blood flow through arteriovenous fistulae in patients undergoing hemodialysis needs to be within a certain range for optimal management. Magnetic resonance (MR) velocity mapping is a new modality that allows the noninvasive measurement of blood flow volume. This technique was applied in 13 patients with either a Brescia-Cimino shunt (N = 6) or a Polytetrafluoroethylene graft (Goretex, N = 7). Fistula flow volume measured by MR velocity mapping was 1386 +/- 411 ml/min (mean +/- SD, range 644 to 1921 ml/min). Interstudy reproducibility of MR velocity mapping was good (r = 0.94). MR velocity mapping derived flow volumes showed good correlation with values obtained with an indicator dilution technique using Indocyanine Green (ICG) which was performed simultaneously in eight patients (r = 0.86). We conclude that MR velocity mapping is an accurate noninvasive method to quantify flow volume through arteriovenous fistulae in patients requiring hemodialysis.
引用
收藏
页码:884 / 889
页数:6
相关论文
共 50 条
  • [41] MILESTONES IN MAGNETIC-RESONANCE - A NEW METHOD OF MEASURING NUCLEAR MAGNETIC-MOMENT
    HURWITZ, R
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 131 - 133
  • [42] WHAT IS BLOOD-FLOW IN HEMODIALYSIS - METHOD TO MEASURE IT
    DUPUIS, F
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1979, 2 (05): : 266 - 266
  • [43] INVIVO EVALUATION OF NUCLEAR MAGNETIC-RESONANCE FLOWMETRY - BLOOD-FLOW THROUGH THE NORMAL FOREARM
    SALLESCUNHA, SX
    HALBACH, RE
    BATTOCLETTI, JH
    SANCES, A
    EVANS, SM
    MEDICAL INSTRUMENTATION, 1982, 16 (06): : 295 - 298
  • [44] BLOOD-FLOW ANALYSIS OF THE FALSE LUMEN IN PATIENTS WITH DISSECTING ANEURYSM BY MAGNETIC-RESONANCE IMAGING
    OKAMURA, M
    OZAWA, S
    OHTA, T
    OKADA, M
    NAKAMURA, K
    YOSHIDA, Y
    MUKOHARA, N
    OGAWA, K
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (09): : 936 - 936
  • [45] OBLIQUE CINE MAGNETIC-RESONANCE BLOOD-FLOW IMAGING TO ASSESS CHANGES IN WALL MOTION
    ASKENASE, A
    CHEN, G
    THOMPSON, W
    ISKANDRIAN, AS
    HEO, J
    HELFANT, RH
    CIRCULATION, 1987, 76 (04) : 29 - 29
  • [46] CEREBRAL BLOOD-FLOW AND NUCLEAR MAGNETIC-RESONANCE STUDIES IN CHRONIC MULTIPLE-SCLEROSIS
    EIDELMAN, BH
    YONAS, H
    LATCHAW, RE
    DEEB, Z
    GUR, D
    ANNALS OF NEUROLOGY, 1984, 16 (01) : 141 - 142
  • [47] FLUOROCARBON-23 MEASURE OF CAT CEREBRAL BLOOD-FLOW BY NUCLEAR MAGNETIC-RESONANCE
    EWING, JR
    BRANCH, CA
    FAGAN, SC
    HELPERN, JA
    SIMKINS, RT
    BUTT, SM
    WELCH, KMA
    STROKE, 1990, 21 (01) : 100 - 106
  • [48] MAGNETIC-RESONANCE CHARACTERIZATION OF PULMONARY ARTERIAL BLOOD-FLOW AFTER SINGLE LUNG TRANSPLANTATION
    MOHIADDIN, RH
    PAZ, R
    THEODOROPOULOS, S
    FIRMIN, DN
    LONGMORE, DB
    YACOUB, MH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (06): : 1016 - 1023
  • [49] QUANTITATION OF ANTEGRADE AND RETROGRADE BLOOD-FLOW IN THE HUMAN AORTA BY MAGNETIC-RESONANCE VELOCITY MAPPING
    BOGREN, HG
    KLIPSTEIN, RH
    FIRMIN, DN
    MOHIADDIN, RH
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    AMERICAN HEART JOURNAL, 1989, 117 (06) : 1214 - 1222
  • [50] NEW METHOD TO DETERMINE BLOOD-FLOW BY PUNCTIFORM MEASURING OF INDICATOR CONCENTRATION
    WODICK, R
    LUBBERS, DW
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1976, 362 : R7 - R7