摘要
Blood flow through arteriovenous fistulae in patients undergoing hemodialysis needs to be within a certain range for optimal management. Magnetic resonance (MR) velocity mapping is a new modality that allows the noninvasive measurement of blood flow volume. This technique was applied in 13 patients with either a Brescia-Cimino shunt (N = 6) or a Polytetrafluoroethylene graft (Goretex, N = 7). Fistula flow volume measured by MR velocity mapping was 1386 +/- 411 ml/min (mean +/- SD, range 644 to 1921 ml/min). Interstudy reproducibility of MR velocity mapping was good (r = 0.94). MR velocity mapping derived flow volumes showed good correlation with values obtained with an indicator dilution technique using Indocyanine Green (ICG) which was performed simultaneously in eight patients (r = 0.86). We conclude that MR velocity mapping is an accurate noninvasive method to quantify flow volume through arteriovenous fistulae in patients requiring hemodialysis.
引用
收藏
页码:884 / 889
页数:6
相关论文
共 50 条
  • [21] MAGNETIC-RESONANCE TECHNIQUES FOR BLOOD-FLOW MEASUREMENT AND VASCULAR IMAGING
    RUTT, BK
    NAPEL, S
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (01): : 21 - 30
  • [22] INVIVO EVALUATION OF FEMORAL BLOOD-FLOW MEASURED WITH MAGNETIC-RESONANCE
    HENRIKSEN, O
    STAHLBERG, F
    THOMSEN, C
    MOGELVANG, J
    PERSSON, B
    ACTA RADIOLOGICA, 1989, 30 (02) : 153 - 157
  • [23] BLOOD-FLOW PATTERNS IN THE HUMAN AORTA STUDIED BY MAGNETIC-RESONANCE
    KLIPSTEIN, RH
    FIRMIN, DN
    UNDERWOOD, SR
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1987, 58 (04): : 316 - 323
  • [24] BLOOD-FLOW MEASUREMENTS BY NUCLEAR MAGNETIC-RESONANCE - RECENT PROGRESS
    SINGER, JR
    LIBOVE, J
    NORTON, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 777 - 777
  • [25] VISUALIZATION OF CORONARY ANATOMY AND BLOOD-FLOW BY MAGNETIC-RESONANCE IMAGING
    OHNISHI, S
    FUKUI, S
    ATSUMI, C
    MORITA, R
    FUJII, K
    KUSUOKA, H
    KITABATAKE, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1988, 52 (08): : 869 - 870
  • [26] NEW TECHNIQUE FOR MEASURING BLOOD-FLOW IN POLYTETRAFLUORETHYLENE GRAFTS FOR HEMODIALYSIS
    KAYE, M
    LEMAITRE, P
    OREGAN, S
    CLINICAL NEPHROLOGY, 1977, 8 (06) : 533 - 534
  • [27] MAGNETIC-RESONANCE ANGIOGRAPHY OF HEMODIALYSIS FISTULAS - EVALUATION OF ANATOMY AND FUNCTION
    WALDMAN, GJ
    PATTYNAMA, P
    CHANG, PC
    VERBURGH, CA
    REIBER, JHC
    DEROOS, A
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 429 - 429
  • [28] NUCLEAR MAGNETIC-RESONANCE BLOOD-FLOW MEASUREMENTS IN THE HUMAN-BRAIN
    SINGER, JR
    CROOKS, LE
    SCIENCE, 1983, 221 (4611) : 654 - 656
  • [29] PHYSIOLOGICAL ALTERATIONS IN CRANIAL BLOOD-FLOW DEMONSTRATED BY MAGNETIC-RESONANCE ANGIOGRAPHY
    PORTMAN, MA
    COOPER, TG
    POTCHEN, EJ
    INVESTIGATIVE RADIOLOGY, 1992, 27 (03) : 240 - 244
  • [30] PULMONARY-ARTERY BLOOD-FLOW PATTERNS STUDIED BY MAGNETIC-RESONANCE
    BOGREN, H
    KLIPSTEIN, RH
    MOHIADDIN, R
    UNDERWOOD, SR
    FIRMIN, DN
    REES, RSO
    LONGMORE, DB
    BRITISH HEART JOURNAL, 1988, 59 (01): : 141 - 142