DETERMINATION OF THE MONOAMINE OXIDASE-B INHIBITOR RO-19-6327 IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PRECOLUMN DERIVATIZATION WITH FLUORESCAMINE AND FLUORESCENCE DETECTION

被引:5
作者
WYSS, R
PHILIPP, W
机构
[1] Pharmaceutical Research, Department of Drug Metabolism, F. Hoffmann-La Roche Ltd., CH-4002 Basle
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 507卷
关键词
D O I
10.1016/S0021-9673(01)84195-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A specific high-performance liquid chromatographic (HPLC) method using precolumn derivatization and fluorescence detection was developed for the determination of the monoamine oxidase B inhibitor Ro 19-6327 in human plasma. After extraction of the basified plasma with tert-butyl methyl ether-1-butanol (8:2, v/v) and back-extraction into dilute phosphoric acid, the solution was neutralized with phosphate buffer and the drug derivatized with fluorescamine. The derivative was chromatographed on a reversed-phase C8 column, using phosphate buffer-acetonitrile (68:32, v/v) as mobile phase, and fluorescence detection (excitation 370 nm, emission 485 nm). The limit of quantification was 1 ng/ml using 1 ml of plasma. The recovery was 79% in the range 5-200 ng/ml and the inter-assay precision was 3.1-7.9% in the range 2-500 ng/ml. The compound proved to be stable in human plasma. Moderate instability was found in rat plasma and, surprisingly, severe instability in dog plasma. Measures for handling unstable dog plasma samples are described. An HPLC method with UV detection was used for the analysis of dog and rat plasma samples, which is also described briefly. The fluorescence method, which was five times more sensitive than the UV method, was successfully applied to a human tolerance study. © 1990.
引用
收藏
页码:187 / 198
页数:12
相关论文
共 16 条
[1]   DETERMINATION OF A PRODRUG OF TRANEXAMIC ACID IN WHOLE-BLOOD BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION WITH FLUORESCAMINE [J].
ABRAHAMSSON, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1986, 4 (03) :399-406
[2]   METABOLISM OF AMLODIPINE IN THE RAT AND THE DOG - A SPECIES-DIFFERENCE [J].
BERESFORD, AP ;
MACRAE, PV ;
STOPHER, DA .
XENOBIOTICA, 1988, 18 (02) :169-182
[3]  
DAPRADA M, 1987, PHARM TOXICOL S1, V60, P10
[4]   STUDIES ON REACTION OF FLUORESCAMINE WITH PRIMARY AMINES [J].
DE BERNARDO, S ;
WEIGELE, M ;
TOOME, V ;
MANHART, K ;
LEIMGRUBER, W ;
BOHLEN, P ;
STEIN, S ;
UDENFRIEND, S .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1974, 163 (01) :390-399
[5]   THE USE OF A PRE-COLUMN FOR THE DIRECT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE ANTI-DEPRESSANTS CLOVOXAMINE AND FLUVOXAMINE IN PLASMA [J].
DEJONG, GJ .
JOURNAL OF CHROMATOGRAPHY, 1980, 183 (02) :203-211
[6]   DETERMINATION OF PYRROLIDINONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DELL, D ;
WENDT, G ;
BUCHELI, F ;
TRAUTMANN, KH .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :125-136
[7]   DETERMINATION OF AMINO-ACIDS WITH 9-FLUORENYLMETHYL CHLOROFORMATE AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
EINARSSON, S ;
JOSEFSSON, B ;
LAGERKVIST, S .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :609-618
[8]   DETERMINATION OF THE NEW MONOAMINE-OXIDASE INHIBITOR MOCLOBEMIDE AND 3 OF ITS METABOLITES IN BIOLOGICAL-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GESCHKE, R ;
KORNER, J ;
EGGERS, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (01) :111-120
[9]   LIMITS OF THE INTERNAL STANDARD TECHNIQUE IN CHROMATOGRAPHY [J].
HAEFELFINGER, P .
JOURNAL OF CHROMATOGRAPHY, 1981, 218 (1-3) :73-81
[10]  
Jauch R., UNPUB